{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/14503"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/14503","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Supercritical Gas Cooling and Near-Critical-Pressure Condensation of Refrigerant Blends in Microchannels","abstract":"A study of heat transfer and pressure drop in zero ozone-depletion-potential (ODP) ‎refrigerant blends in small diameter tubes was conducted. The azeotropic refrigerant ‎blend R410A (equal parts of R32 and R125 by mass) has zero ODP and has properties ‎similar to R22, and is therefore of interest for vapor compression cycles in high-‎temperature-lift space-conditioning and water heating applications. Smaller tubes lead to ‎higher heat transfer coefficients and are better suited for high operating pressures.‎ Heat transfer coefficients and pressure drops for R410A were determined experimentally ‎during condensation across the entire vapor-liquid dome at 0.8, 0.9xPcritical and gas ‎cooling at 1.0, 1.1, 1.2xPcritical in three different round tubes (D = 3.05, 1.52, 0.76 mm) ‎over a mass flux range of 200 < G < 800 kg/m2-s. A thermal amplification technique was ‎used to accurately determine the heat duty for condensation in small quality increments ‎or supercritical cooling across small temperature changes while ensuring low ‎uncertainties in the refrigerant heat transfer coefficients. ‎ The data from this study were used in conjunction with data obtained under similar ‎operating conditions for refrigerants R404A and R410A in tubes of diameter 6.22 and ‎‎9.40 mm to develop models to predict heat transfer and pressure drop in tubes with ‎diameters ranging from 0.76 to 9.40 mm during condensation. Similarly, in the ‎supercritical states, heat transfer and pressure drop models were developed to account for ‎the sharp variations in the thermophysical properties near the critical point.‎ The physical understanding and models resulting from this investigation provide the ‎information necessary for designing and optimizing new components that utilize R410A ‎for air-conditioning and heat pumping applications.‎","abstract_html":"A study of heat transfer and pressure drop in zero ozone-depletion-potential (ODP) ‎refrigerant blends in small diameter tubes was conducted. The azeotropic refrigerant ‎blend R410A (equal parts of R32 and R125 by mass) has zero ODP and has properties ‎similar to R22, and is therefore of interest for vapor compression cycles in high-‎temperature-lift space-conditioning and water heating applications. Smaller tubes lead to ‎higher heat transfer coefficients and are better suited for high operating pressures.‎ Heat transfer coefficients and pressure drops for R410A were determined experimentally ‎during condensation across the entire vapor-liquid dome at 0.8, 0.9xPcritical and gas ‎cooling at 1.0, 1.1, 1.2xPcritical in three different round tubes (D = 3.05, 1.52, 0.76 mm) ‎over a mass flux range of 200 &lt; G &lt; 800 kg/m2-s. A thermal amplification technique was ‎used to accurately determine the heat duty for condensation in small quality increments ‎or supercritical cooling across small temperature changes while ensuring low ‎uncertainties in the refrigerant heat transfer coefficients. ‎ The data from this study were used in conjunction with data obtained under similar ‎operating conditions for refrigerants R404A and R410A in tubes of diameter 6.22 and ‎‎9.40 mm to develop models to predict heat transfer and pressure drop in tubes with ‎diameters ranging from 0.76 to 9.40 mm during condensation. Similarly, in the ‎supercritical states, heat transfer and pressure drop models were developed to account for ‎the sharp variations in the thermophysical properties near the critical point.‎ The physical understanding and models resulting from this investigation provide the ‎information necessary for designing and optimizing new components that utilize R410A ‎for air-conditioning and heat pumping applications.‎","abstract_has_math":false,"creators":["Andresen, Ulf Christian"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["Garimella, Srinivas"],"committee_chairs":[],"committee_members":["Donald Webster","Ghiaasiaan, S. Mostafa","Graham, Samuel","Tom Fuller"],"year":2006,"date_issued":"2006-12-14","date_published":"2006-12-14","updated_at":"2026-11-19T04:14:40Z","subjects":["Condensation","Microchannels","Supercritical","Cooling","Minichannels","R410A","R404A","R22","Azeotropic","Single-tube","Multiport","Heat exchanger","Refrigerants Thermomechanical properties","Expansion (Heat)","Heat Transmission Mathematical models"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/14503","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/14503","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F14503","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Garimella, Srinivas"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Donald Webster","Ghiaasiaan, S. Mostafa","Graham, Samuel","Tom Fuller"]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["George W. Woodruff School of Mechanical Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Andresen, Ulf Christian"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2007-05-25T17:21:57Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2007-05-25T17:21:57Z"]},{"key":"dc:date.issued","label":"Date","values":["2006-12-14"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["7c74399b-6962-4814-9d2a-51f8b9c41e1f"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Doctor of Philosophy with a Major in Mechanical Engineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["c01ff908-c25f-439b-bf10-a074ed886bb7","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["a27a5c68-ea1b-411c-8430-0e28936f53d2"]},{"key":"dc:type","label":"Dc Type","values":["Text","Dissertation"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Condensation","Microchannels","Supercritical","Cooling","Minichannels","R410A","R404A","R22","Azeotropic","Single-tube","Multiport","Heat exchanger"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Refrigerants Thermomechanical properties","Expansion (Heat)","Heat Transmission Mathematical models"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/14503"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A study of heat transfer and pressure drop in zero ozone-depletion-potential (ODP) ‎refrigerant blends in small diameter tubes was conducted. The azeotropic refrigerant ‎blend R410A (equal parts of R32 and R125 by mass) has zero ODP and has properties ‎similar to R22, and is therefore of interest for vapor compression cycles in high-‎temperature-lift space-conditioning and water heating applications. Smaller tubes lead to ‎higher heat transfer coefficients and are better suited for high operating pressures.‎ Heat transfer coefficients and pressure drops for R410A were determined experimentally ‎during condensation across the entire vapor-liquid dome at 0.8, 0.9xPcritical and gas ‎cooling at 1.0, 1.1, 1.2xPcritical in three different round tubes (D = 3.05, 1.52, 0.76 mm) ‎over a mass flux range of 200 < G < 800 kg/m2-s. A thermal amplification technique was ‎used to accurately determine the heat duty for condensation in small quality increments ‎or supercritical cooling across small temperature changes while ensuring low ‎uncertainties in the refrigerant heat transfer coefficients. ‎ The data from this study were used in conjunction with data obtained under similar ‎operating conditions for refrigerants R404A and R410A in tubes of diameter 6.22 and ‎‎9.40 mm to develop models to predict heat transfer and pressure drop in tubes with ‎diameters ranging from 0.76 to 9.40 mm during condensation. Similarly, in the ‎supercritical states, heat transfer and pressure drop models were developed to account for ‎the sharp variations in the thermophysical properties near the critical point.‎ The physical understanding and models resulting from this investigation provide the ‎information necessary for designing and optimizing new components that utilize R410A ‎for air-conditioning and heat pumping applications.‎"]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph.D."]},{"key":"dc:title","label":"Title","values":["Supercritical Gas Cooling and Near-Critical-Pressure Condensation of Refrigerant Blends in Microchannels"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Garimella, Srinivas"],"dc:contributor.committeemember":["Donald Webster","Ghiaasiaan, S. Mostafa","Graham, Samuel","Tom Fuller"],"dc:contributor.department":["Mechanical Engineering"],"dc:contributor.other":["George W. Woodruff School of Mechanical Engineering","College of Engineering"],"dc:creator":["Andresen, Ulf Christian"],"dc:date.accessioned":["2007-05-25T17:21:57Z"],"dc:date.available":["2007-05-25T17:21:57Z"],"dc:date.issued":["2006-12-14"],"dc:description.abstract":["A study of heat transfer and pressure drop in zero ozone-depletion-potential (ODP) ‎refrigerant blends in small diameter tubes was conducted. The azeotropic refrigerant ‎blend R410A (equal parts of R32 and R125 by mass) has zero ODP and has properties ‎similar to R22, and is therefore of interest for vapor compression cycles in high-‎temperature-lift space-conditioning and water heating applications. Smaller tubes lead to ‎higher heat transfer coefficients and are better suited for high operating pressures.‎ Heat transfer coefficients and pressure drops for R410A were determined experimentally ‎during condensation across the entire vapor-liquid dome at 0.8, 0.9xPcritical and gas ‎cooling at 1.0, 1.1, 1.2xPcritical in three different round tubes (D = 3.05, 1.52, 0.76 mm) ‎over a mass flux range of 200 < G < 800 kg/m2-s. A thermal amplification technique was ‎used to accurately determine the heat duty for condensation in small quality increments ‎or supercritical cooling across small temperature changes while ensuring low ‎uncertainties in the refrigerant heat transfer coefficients. ‎ The data from this study were used in conjunction with data obtained under similar ‎operating conditions for refrigerants R404A and R410A in tubes of diameter 6.22 and ‎‎9.40 mm to develop models to predict heat transfer and pressure drop in tubes with ‎diameters ranging from 0.76 to 9.40 mm during condensation. Similarly, in the ‎supercritical states, heat transfer and pressure drop models were developed to account for ‎the sharp variations in the thermophysical properties near the critical point.‎ The physical understanding and models resulting from this investigation provide the ‎information necessary for designing and optimizing new components that utilize R410A ‎for air-conditioning and heat pumping applications.‎"],"dc:description.degree":["Ph.D."],"dc:identifier.uri":["http://hdl.handle.net/1853/14503"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["7c74399b-6962-4814-9d2a-51f8b9c41e1f"],"dc:relation.ispartofseries":["Doctor of Philosophy with a Major in Mechanical Engineering"],"dc:relation.orgunit":["c01ff908-c25f-439b-bf10-a074ed886bb7","7c022d60-21d5-497c-b552-95e489a06569"],"dc:relation.seriesentity":["a27a5c68-ea1b-411c-8430-0e28936f53d2"],"dc:subject":["Condensation","Microchannels","Supercritical","Cooling","Minichannels","R410A","R404A","R22","Azeotropic","Single-tube","Multiport","Heat exchanger"],"dc:subject.lcsh":["Refrigerants Thermomechanical properties","Expansion (Heat)","Heat Transmission Mathematical models"],"dc:title":["Supercritical Gas Cooling and Near-Critical-Pressure Condensation of Refrigerant Blends in Microchannels"],"dc:type":["Text","Dissertation"],"dspace:entity.type":["Publication"]},"updated_at":"2026-11-19T04:14:40Z"}