{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/14530"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/14530","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Near-Wall Thermometry via Total Internal Reflection Fluorescence Micro-Thermometry (TIR-FMT)","abstract":"To effectively design systems of microchannels it is necessary for scientists and engineers to understand thermal transport characteristics of microchannels. To experimentally determine the convective heat transfer coefficient of microchannels it is necessary to measure both the bulk and surface temperature fields. This investigation aims to develop a technique, named Total Internal Reflection Fluorescent Micro-Thermometry (TIR-FMT), to measure the temperature of water within several hundred nanometers of a wall--effectively, the surface temperature of the wall. In TIR-FMT, an evanescent-wave is generated in the water near the wall. The intensity of this evanescent-wave decays exponentially with distance from the wall. A fluorophore if illuminated by the evanescent-wave can absorb a photon. Excited fluorophores subsequently emit red-shifted photons, which are called fluorescence. The probability of a fluorescent emission is temperature-dependent. Therefore, by monitoring the intensity of the fluorescence a correlation can be made to the temperature of the region of illumination. Using the TIR-FMT technique the temperature dependence of the fluorescence intensity from buffered fluorescein (pH=9.2) was determined to be 1.35%/C. TIR-FMT can be used to measure the temperature of a fluorophore solution within 600 nm of a wall across a temperature range of 12.5-55C. The average uncertainties (95% confidence) of the temperature measured was determined to be 2.3C and 1.5C for a single 1.5x1.5 and #956;m pixel and the entire 715x950 and #956;m viewfield. By spatial averaging, average uncertainties of 2.0C and 1.8C were attained with spatial resolutions of 16x16 and 100x100 and #956;m, respectively.","abstract_html":"To effectively design systems of microchannels it is necessary for scientists and engineers to understand thermal transport characteristics of microchannels. To experimentally determine the convective heat transfer coefficient of microchannels it is necessary to measure both the bulk and surface temperature fields. This investigation aims to develop a technique, named Total Internal Reflection Fluorescent Micro-Thermometry (TIR-FMT), to measure the temperature of water within several hundred nanometers of a wall--effectively, the surface temperature of the wall. In TIR-FMT, an evanescent-wave is generated in the water near the wall. The intensity of this evanescent-wave decays exponentially with distance from the wall. A fluorophore if illuminated by the evanescent-wave can absorb a photon. Excited fluorophores subsequently emit red-shifted photons, which are called fluorescence. The probability of a fluorescent emission is temperature-dependent. Therefore, by monitoring the intensity of the fluorescence a correlation can be made to the temperature of the region of illumination. Using the TIR-FMT technique the temperature dependence of the fluorescence intensity from buffered fluorescein (pH=9.2) was determined to be 1.35%/C. TIR-FMT can be used to measure the temperature of a fluorophore solution within 600 nm of a wall across a temperature range of 12.5-55C. The average uncertainties (95% confidence) of the temperature measured was determined to be 2.3C and 1.5C for a single 1.5x1.5 and #956;m pixel and the entire 715x950 and #956;m viewfield. By spatial averaging, average uncertainties of 2.0C and 1.8C were attained with spatial resolutions of 16x16 and 100x100 and #956;m, respectively.","abstract_has_math":false,"creators":["Suda-Cederquist, Keith David"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["Yoda, Minami"],"committee_chairs":[],"committee_members":["Joshi, Yogendra K.","Zhuomin Zhang"],"year":2007,"date_issued":"2007-03-26","date_published":"2007-03-26","updated_at":"2026-11-19T06:10:38Z","subjects":["Surface temperature","Total internal reflection","Fluorescence","Thermometry","Fluorescent","TIR-FMT","Microchannels","Evanescent wave","Rhodamine b","Fluorescein","Temperature measurements","Microelectronics","Heat Transmission","Fluorescence microscopy"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/14530","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/14530","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F14530","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Yoda, Minami"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Joshi, Yogendra K.","Zhuomin Zhang"]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["George W. Woodruff School of Mechanical Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Suda-Cederquist, Keith David"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2007-05-25T17:24:45Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2007-05-25T17:24:45Z"]},{"key":"dc:date.issued","label":"Date","values":["2007-03-26"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["d318e6bc-95be-4fd2-bb0a-19fe480686df"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["c01ff908-c25f-439b-bf10-a074ed886bb7","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:type","label":"Dc Type","values":["Text","Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Surface temperature","Total internal reflection","Fluorescence","Thermometry","Fluorescent","TIR-FMT","Microchannels","Evanescent wave","Rhodamine b","Fluorescein"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Temperature measurements","Microelectronics","Heat Transmission","Fluorescence microscopy"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/14530"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["To effectively design systems of microchannels it is necessary for scientists and engineers to understand thermal transport characteristics of microchannels. To experimentally determine the convective heat transfer coefficient of microchannels it is necessary to measure both the bulk and surface temperature fields. This investigation aims to develop a technique, named Total Internal Reflection Fluorescent Micro-Thermometry (TIR-FMT), to measure the temperature of water within several hundred nanometers of a wall--effectively, the surface temperature of the wall. In TIR-FMT, an evanescent-wave is generated in the water near the wall. The intensity of this evanescent-wave decays exponentially with distance from the wall. A fluorophore if illuminated by the evanescent-wave can absorb a photon. Excited fluorophores subsequently emit red-shifted photons, which are called fluorescence. The probability of a fluorescent emission is temperature-dependent. Therefore, by monitoring the intensity of the fluorescence a correlation can be made to the temperature of the region of illumination. Using the TIR-FMT technique the temperature dependence of the fluorescence intensity from buffered fluorescein (pH=9.2) was determined to be 1.35%/C. TIR-FMT can be used to measure the temperature of a fluorophore solution within 600 nm of a wall across a temperature range of 12.5-55C. The average uncertainties (95% confidence) of the temperature measured was determined to be 2.3C and 1.5C for a single 1.5x1.5 and #956;m pixel and the entire 715x950 and #956;m viewfield. By spatial averaging, average uncertainties of 2.0C and 1.8C were attained with spatial resolutions of 16x16 and 100x100 and #956;m, respectively."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.S."]},{"key":"dc:title","label":"Title","values":["Near-Wall Thermometry via Total Internal Reflection Fluorescence Micro-Thermometry (TIR-FMT)"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Yoda, Minami"],"dc:contributor.committeemember":["Joshi, Yogendra K.","Zhuomin Zhang"],"dc:contributor.department":["Mechanical Engineering"],"dc:contributor.other":["George W. Woodruff School of Mechanical Engineering","College of Engineering"],"dc:creator":["Suda-Cederquist, Keith David"],"dc:date.accessioned":["2007-05-25T17:24:45Z"],"dc:date.available":["2007-05-25T17:24:45Z"],"dc:date.issued":["2007-03-26"],"dc:description.abstract":["To effectively design systems of microchannels it is necessary for scientists and engineers to understand thermal transport characteristics of microchannels. To experimentally determine the convective heat transfer coefficient of microchannels it is necessary to measure both the bulk and surface temperature fields. This investigation aims to develop a technique, named Total Internal Reflection Fluorescent Micro-Thermometry (TIR-FMT), to measure the temperature of water within several hundred nanometers of a wall--effectively, the surface temperature of the wall. In TIR-FMT, an evanescent-wave is generated in the water near the wall. The intensity of this evanescent-wave decays exponentially with distance from the wall. A fluorophore if illuminated by the evanescent-wave can absorb a photon. Excited fluorophores subsequently emit red-shifted photons, which are called fluorescence. The probability of a fluorescent emission is temperature-dependent. Therefore, by monitoring the intensity of the fluorescence a correlation can be made to the temperature of the region of illumination. Using the TIR-FMT technique the temperature dependence of the fluorescence intensity from buffered fluorescein (pH=9.2) was determined to be 1.35%/C. TIR-FMT can be used to measure the temperature of a fluorophore solution within 600 nm of a wall across a temperature range of 12.5-55C. The average uncertainties (95% confidence) of the temperature measured was determined to be 2.3C and 1.5C for a single 1.5x1.5 and #956;m pixel and the entire 715x950 and #956;m viewfield. By spatial averaging, average uncertainties of 2.0C and 1.8C were attained with spatial resolutions of 16x16 and 100x100 and #956;m, respectively."],"dc:description.degree":["M.S."],"dc:identifier.uri":["http://hdl.handle.net/1853/14530"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["d318e6bc-95be-4fd2-bb0a-19fe480686df"],"dc:relation.orgunit":["c01ff908-c25f-439b-bf10-a074ed886bb7","7c022d60-21d5-497c-b552-95e489a06569"],"dc:subject":["Surface temperature","Total internal reflection","Fluorescence","Thermometry","Fluorescent","TIR-FMT","Microchannels","Evanescent wave","Rhodamine b","Fluorescein"],"dc:subject.lcsh":["Temperature measurements","Microelectronics","Heat Transmission","Fluorescence microscopy"],"dc:title":["Near-Wall Thermometry via Total Internal Reflection Fluorescence Micro-Thermometry (TIR-FMT)"],"dc:type":["Text","Thesis"],"dspace:entity.type":["Publication"]},"updated_at":"2026-11-19T06:10:38Z"}