{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/14585"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/14585","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Nano Thermal and Contact Potential Analysis with Heated Probe Tips","abstract":"This work describes two closed-loop atomic force microscopy methods that utilize the heated silicon probe to interrogate surfaces. The first method identifies the softening temperatures of a selected polymer and organic substrate as a function of contact force and surface hardness. Motivation partly stems from nanosampling, which requires knowledge of phase-specific transitions to identify and extract mass from multicomponent systems for chemical analysis. In the second method, the cantilever is implemented as a Kelvin probe to study the effect of temperature on the measured contact potential. The objective is to ascertain whether the probe functions as a capable electrode for scanning Kelvin probe microscopy (SKPM) applications. This was achieved by performing heated force-distance experiments on a biased gold film with the tip operating at various potentials. Both experiments examine the interaction between the tip and substrate and analyze sample effects both induced and sensed by the cantilever.","abstract_html":"This work describes two closed-loop atomic force microscopy methods that utilize the heated silicon probe to interrogate surfaces. The first method identifies the softening temperatures of a selected polymer and organic substrate as a function of contact force and surface hardness. Motivation partly stems from nanosampling, which requires knowledge of phase-specific transitions to identify and extract mass from multicomponent systems for chemical analysis. In the second method, the cantilever is implemented as a Kelvin probe to study the effect of temperature on the measured contact potential. The objective is to ascertain whether the probe functions as a capable electrode for scanning Kelvin probe microscopy (SKPM) applications. This was achieved by performing heated force-distance experiments on a biased gold film with the tip operating at various potentials. Both experiments examine the interaction between the tip and substrate and analyze sample effects both induced and sensed by the cantilever.","abstract_has_math":false,"creators":["Remmert, Jessica Lynn"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["King, William P."],"committee_chairs":[],"committee_members":["Graham, Samuel","Henderson, Clifford"],"year":2007,"date_issued":"2007-04-09","date_published":"2007-04-09","updated_at":"2026-11-19T04:51:09Z","subjects":["Atomic force microscopy","Heated silicon cantilever","Local thermal analysis","Contact potential analysis","Kelvin probe","Probes (Electronic instruments)"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/14585","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/14585","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F14585","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["King, William P."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Graham, Samuel","Henderson, Clifford"]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["George W. Woodruff School of Mechanical Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Remmert, Jessica Lynn"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2007-05-25T17:34:22Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2007-05-25T17:34:22Z"]},{"key":"dc:date.issued","label":"Date","values":["2007-04-09"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Master of Science in Mechanical Engineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["c01ff908-c25f-439b-bf10-a074ed886bb7","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["028ba2d8-6c6e-4f8a-a480-51b555d14e9d"]},{"key":"dc:type","label":"Dc Type","values":["Text","Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Atomic force microscopy","Heated silicon cantilever","Local thermal analysis","Contact potential analysis","Kelvin probe"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Atomic force microscopy","Probes (Electronic instruments)"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/14585"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This work describes two closed-loop atomic force microscopy methods that utilize the heated silicon probe to interrogate surfaces. The first method identifies the softening temperatures of a selected polymer and organic substrate as a function of contact force and surface hardness. Motivation partly stems from nanosampling, which requires knowledge of phase-specific transitions to identify and extract mass from multicomponent systems for chemical analysis. In the second method, the cantilever is implemented as a Kelvin probe to study the effect of temperature on the measured contact potential. The objective is to ascertain whether the probe functions as a capable electrode for scanning Kelvin probe microscopy (SKPM) applications. This was achieved by performing heated force-distance experiments on a biased gold film with the tip operating at various potentials. Both experiments examine the interaction between the tip and substrate and analyze sample effects both induced and sensed by the cantilever."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.S."]},{"key":"dc:title","label":"Title","values":["Nano Thermal and Contact Potential Analysis with Heated Probe Tips"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["King, William P."],"dc:contributor.committeemember":["Graham, Samuel","Henderson, Clifford"],"dc:contributor.department":["Mechanical Engineering"],"dc:contributor.other":["George W. Woodruff School of Mechanical Engineering","College of Engineering"],"dc:creator":["Remmert, Jessica Lynn"],"dc:date.accessioned":["2007-05-25T17:34:22Z"],"dc:date.available":["2007-05-25T17:34:22Z"],"dc:date.issued":["2007-04-09"],"dc:description.abstract":["This work describes two closed-loop atomic force microscopy methods that utilize the heated silicon probe to interrogate surfaces. The first method identifies the softening temperatures of a selected polymer and organic substrate as a function of contact force and surface hardness. Motivation partly stems from nanosampling, which requires knowledge of phase-specific transitions to identify and extract mass from multicomponent systems for chemical analysis. In the second method, the cantilever is implemented as a Kelvin probe to study the effect of temperature on the measured contact potential. The objective is to ascertain whether the probe functions as a capable electrode for scanning Kelvin probe microscopy (SKPM) applications. This was achieved by performing heated force-distance experiments on a biased gold film with the tip operating at various potentials. Both experiments examine the interaction between the tip and substrate and analyze sample effects both induced and sensed by the cantilever."],"dc:description.degree":["M.S."],"dc:identifier.uri":["http://hdl.handle.net/1853/14585"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.ispartofseries":["Master of Science in Mechanical Engineering"],"dc:relation.orgunit":["c01ff908-c25f-439b-bf10-a074ed886bb7","7c022d60-21d5-497c-b552-95e489a06569"],"dc:relation.seriesentity":["028ba2d8-6c6e-4f8a-a480-51b555d14e9d"],"dc:subject":["Atomic force microscopy","Heated silicon cantilever","Local thermal analysis","Contact potential analysis","Kelvin probe"],"dc:subject.lcsh":["Atomic force microscopy","Probes (Electronic instruments)"],"dc:title":["Nano Thermal and Contact Potential Analysis with Heated Probe Tips"],"dc:type":["Text","Thesis"],"dspace:entity.type":["Publication"]},"updated_at":"2026-11-19T04:51:09Z"}