{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/16192"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/16192","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"An Electronic System for Extracellular Neural Stimulation and Recording","abstract":"A system for extracellular neural interfacing that had the capability for stimulation and recording at multiple electrodes was presented. As the core of this system was a custom integrated circuit (IC) that contained low-noise amplifiers, stimulation buffers, and artifact-elimination circuitry. The artifact-elimination circuitry was necessary to prevent the activity of the stimulation buffers from interfering with the normal functioning of the low-noise amplifiers. The integrated circuits were fabricated in in a 0.35 micron CMOS process. We measured input-referred noise levels for the amplifiers as low as 3.50 microvolts (rms) in the in the bandwidth 30 Hz-3 kHz, corresponding to the frequency range of neural action potentials. The power consumption was 120 microwatts, corresponding to a noise-efficiency factor of 14.5. It was possible to resume recording signals within 2 ms of a stimulation, using the same electrode for both stimulation and recording. A filtering algorithm to remove the post-discharge artifact was also presented. The filtering was implemented using a field-programmable gate array (FPGA). The filtering algorithm itself consisted of blanking for the duration of the stimulation and artifact-elimination, followed by a wavelet de-noising. The wavelet de-noising split the signal into frequency ranges, discarded those ranges that did not correspond to neural signals, applied a threshold to the retained signals, and recombined the different frequency ranges into a single signal. The combination of the filtering with the artifact-elimination IC resulted in the capability for artifact-free recordings.","abstract_html":"A system for extracellular neural interfacing that had the capability for stimulation and recording at multiple electrodes was presented. As the core of this system was a custom integrated circuit (IC) that contained low-noise amplifiers, stimulation buffers, and artifact-elimination circuitry. The artifact-elimination circuitry was necessary to prevent the activity of the stimulation buffers from interfering with the normal functioning of the low-noise amplifiers. The integrated circuits were fabricated in in a 0.35 micron CMOS process. We measured input-referred noise levels for the amplifiers as low as 3.50 microvolts (rms) in the in the bandwidth 30 Hz-3 kHz, corresponding to the frequency range of neural action potentials. The power consumption was 120 microwatts, corresponding to a noise-efficiency factor of 14.5. It was possible to resume recording signals within 2 ms of a stimulation, using the same electrode for both stimulation and recording. A filtering algorithm to remove the post-discharge artifact was also presented. The filtering was implemented using a field-programmable gate array (FPGA). The filtering algorithm itself consisted of blanking for the duration of the stimulation and artifact-elimination, followed by a wavelet de-noising. The wavelet de-noising split the signal into frequency ranges, discarded those ranges that did not correspond to neural signals, applied a threshold to the retained signals, and recombined the different frequency ranges into a single signal. The combination of the filtering with the artifact-elimination IC resulted in the capability for artifact-free recordings.","abstract_has_math":false,"creators":["Blum, Richard Alan"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Electrical and Computer Engineering","school":null,"contributors":[],"advisors":["DeWeerth, Stephen P."],"committee_chairs":[],"committee_members":["Allen, Mark","Hasler, Jennifer","Lee, Robert","Wheeler, Bruce"],"year":2007,"date_issued":"2007-07-06","date_published":"2007-07-06","updated_at":"2026-11-19T05:52:19Z","subjects":["VLSI","Electrodes","Stimulation artifact","Electrode modeling","Wavelets"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/16192","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/16192","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F16192","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["DeWeerth, Stephen P."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Allen, Mark","Hasler, Jennifer","Lee, Robert","Wheeler, Bruce"]},{"key":"dc:contributor.department","label":"Department","values":["Electrical and Computer Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["School of Electrical and Computer Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Blum, Richard Alan"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2007-08-16T17:43:31Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2007-08-16T17:43:31Z"]},{"key":"dc:date.issued","label":"Date","values":["2007-07-06"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["6b8c24a1-7328-4161-8715-b26e0231ae78"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Doctor of Philosophy with a Major in Electrical and Computer Engineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["5b7adef2-447c-4270-b9fc-846bd76f80f2","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["3890cd56-8ecf-424b-8074-8f5ebd8dbe15"]},{"key":"dc:type","label":"Dc Type","values":["Text","Dissertation"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["VLSI","Electrodes","Stimulation artifact","Electrode modeling","Wavelets"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/16192"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A system for extracellular neural interfacing that had the capability for stimulation and recording at multiple electrodes was presented. As the core of this system was a custom integrated circuit (IC) that contained low-noise amplifiers, stimulation buffers, and artifact-elimination circuitry. The artifact-elimination circuitry was necessary to prevent the activity of the stimulation buffers from interfering with the normal functioning of the low-noise amplifiers. The integrated circuits were fabricated in in a 0.35 micron CMOS process. We measured input-referred noise levels for the amplifiers as low as 3.50 microvolts (rms) in the in the bandwidth 30 Hz-3 kHz, corresponding to the frequency range of neural action potentials. The power consumption was 120 microwatts, corresponding to a noise-efficiency factor of 14.5. It was possible to resume recording signals within 2 ms of a stimulation, using the same electrode for both stimulation and recording. A filtering algorithm to remove the post-discharge artifact was also presented. The filtering was implemented using a field-programmable gate array (FPGA). The filtering algorithm itself consisted of blanking for the duration of the stimulation and artifact-elimination, followed by a wavelet de-noising. The wavelet de-noising split the signal into frequency ranges, discarded those ranges that did not correspond to neural signals, applied a threshold to the retained signals, and recombined the different frequency ranges into a single signal. The combination of the filtering with the artifact-elimination IC resulted in the capability for artifact-free recordings."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph.D."]},{"key":"dc:title","label":"Title","values":["An Electronic System for Extracellular Neural Stimulation and Recording"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["DeWeerth, Stephen P."],"dc:contributor.committeemember":["Allen, Mark","Hasler, Jennifer","Lee, Robert","Wheeler, Bruce"],"dc:contributor.department":["Electrical and Computer Engineering"],"dc:contributor.other":["School of Electrical and Computer Engineering","College of Engineering"],"dc:creator":["Blum, Richard Alan"],"dc:date.accessioned":["2007-08-16T17:43:31Z"],"dc:date.available":["2007-08-16T17:43:31Z"],"dc:date.issued":["2007-07-06"],"dc:description.abstract":["A system for extracellular neural interfacing that had the capability for stimulation and recording at multiple electrodes was presented. As the core of this system was a custom integrated circuit (IC) that contained low-noise amplifiers, stimulation buffers, and artifact-elimination circuitry. The artifact-elimination circuitry was necessary to prevent the activity of the stimulation buffers from interfering with the normal functioning of the low-noise amplifiers. The integrated circuits were fabricated in in a 0.35 micron CMOS process. We measured input-referred noise levels for the amplifiers as low as 3.50 microvolts (rms) in the in the bandwidth 30 Hz-3 kHz, corresponding to the frequency range of neural action potentials. The power consumption was 120 microwatts, corresponding to a noise-efficiency factor of 14.5. It was possible to resume recording signals within 2 ms of a stimulation, using the same electrode for both stimulation and recording. A filtering algorithm to remove the post-discharge artifact was also presented. The filtering was implemented using a field-programmable gate array (FPGA). The filtering algorithm itself consisted of blanking for the duration of the stimulation and artifact-elimination, followed by a wavelet de-noising. The wavelet de-noising split the signal into frequency ranges, discarded those ranges that did not correspond to neural signals, applied a threshold to the retained signals, and recombined the different frequency ranges into a single signal. The combination of the filtering with the artifact-elimination IC resulted in the capability for artifact-free recordings."],"dc:description.degree":["Ph.D."],"dc:identifier.uri":["http://hdl.handle.net/1853/16192"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["6b8c24a1-7328-4161-8715-b26e0231ae78"],"dc:relation.ispartofseries":["Doctor of Philosophy with a Major in Electrical and Computer Engineering"],"dc:relation.orgunit":["5b7adef2-447c-4270-b9fc-846bd76f80f2","7c022d60-21d5-497c-b552-95e489a06569"],"dc:relation.seriesentity":["3890cd56-8ecf-424b-8074-8f5ebd8dbe15"],"dc:subject":["VLSI","Electrodes","Stimulation artifact","Electrode modeling","Wavelets"],"dc:title":["An Electronic System for Extracellular Neural Stimulation and Recording"],"dc:type":["Text","Dissertation"],"dspace:entity.type":["Publication"]},"updated_at":"2026-11-19T05:52:19Z"}