{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/19837"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/19837","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Experimental and Numerical Investigation of Thermocapillary Effects in Thin Liquid Layers","abstract":"Thin liquid layers have been proposed for heat extraction and protection of the solid surfaces of divertors in magnetic fusion reactors. A number of conceptual designs for plasma-facing components (PFC) use stationary and flowing liquid layers as a renewable first wall for reactor chambers to remove heat and shield solid surfaces from damaging radiation while maintaining acceptable plasma purity levels. Such liquid-protected PFC have the potential to make fusion more commercially attractive by increasing reactor lifetimes and decreasing failure rates. The results of this research will help identify the parameter ranges for successful operation of such protection schemes. This thesis investigates the thermocapillary behavior of axisymmetric horizontal liquid layers with initial heights from 0.27 to 3.0 mm. A negative radial temperature gradient is imposed at the bottom of the liquid layer. Experimental, numerical and asymptotic analyses were carried out for thin layers where buoyancy forces are negligible. A novel asymptotic solution for this axisymmetric geometry was derived from the previous two-dimensional long-wave analysis by Sen et al. (1982). A numerical simulation using the level contour reconstruction method was used to follow the evolution of the liquid-gas interface above an axisymmetric non-isothermal solid surface. Experimental validation of the theoretical and numerical studies was performed using silicone oils of various viscosities (μ = 0.48 × 10-2 9.6 × 10-2 N s/m2). Two measurement techniques, a needle contact method and laser-confocal displacement method, were employed to obtain height profiles for applied temperature differences up to 65°C. Finally, reflectance shadowgraphy was used to visualize free-surface deformation and classify flow regimes in thick layers, where the assumptions of negligible buoyancy and axisymmetric flow are no longer valid. The results of this investigation will allow designers to determine operating windows for successful implementation of liquid-protected PFC.","abstract_html":"Thin liquid layers have been proposed for heat extraction and protection of the solid surfaces of divertors in magnetic fusion reactors. A number of conceptual designs for plasma-facing components (PFC) use stationary and flowing liquid layers as a renewable first wall for reactor chambers to remove heat and shield solid surfaces from damaging radiation while maintaining acceptable plasma purity levels. Such liquid-protected PFC have the potential to make fusion more commercially attractive by increasing reactor lifetimes and decreasing failure rates. The results of this research will help identify the parameter ranges for successful operation of such protection schemes. This thesis investigates the thermocapillary behavior of axisymmetric horizontal liquid layers with initial heights from 0.27 to 3.0 mm. A negative radial temperature gradient is imposed at the bottom of the liquid layer. Experimental, numerical and asymptotic analyses were carried out for thin layers where buoyancy forces are negligible. A novel asymptotic solution for this axisymmetric geometry was derived from the previous two-dimensional long-wave analysis by Sen et al. (1982). A numerical simulation using the level contour reconstruction method was used to follow the evolution of the liquid-gas interface above an axisymmetric non-isothermal solid surface. Experimental validation of the theoretical and numerical studies was performed using silicone oils of various viscosities (μ = 0.48 × 10-2 9.6 × 10-2 N s/m2). Two measurement techniques, a needle contact method and laser-confocal displacement method, were employed to obtain height profiles for applied temperature differences up to 65°C. Finally, reflectance shadowgraphy was used to visualize free-surface deformation and classify flow regimes in thick layers, where the assumptions of negligible buoyancy and axisymmetric flow are no longer valid. The results of this investigation will allow designers to determine operating windows for successful implementation of liquid-protected PFC.","abstract_has_math":false,"creators":["Koehler, Timothy P."],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["Abdel-Khalik, Said I.","Yoda, Minami"],"committee_chairs":[],"committee_members":["Aidun, Cyrus K.","Karl Jacob","Roman Grigoriev","Ghiaasiaan, S. Mostafa"],"year":2007,"date_issued":"2007-10-02","date_published":"2007-10-02","updated_at":"2026-11-19T03:54:48Z","subjects":["Liquid protection","Fusion","Thin films","Thermocapillary","Rupture","Dry-out","Liquid films","Heat Convection","Fusion reactors"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/19837","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/19837","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F19837","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Abdel-Khalik, Said I.","Yoda, Minami"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Aidun, Cyrus K.","Karl Jacob","Roman Grigoriev","Ghiaasiaan, S. Mostafa"]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["George W. Woodruff School of Mechanical Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Koehler, Timothy P."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2008-02-07T18:43:29Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2008-02-07T18:43:29Z"]},{"key":"dc:date.issued","label":"Date","values":["2007-10-02"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["196f5fb4-8c6b-4b41-add5-06b1d33b971c","d318e6bc-95be-4fd2-bb0a-19fe480686df"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Doctor of Philosophy with a Major in Mechanical Engineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["c01ff908-c25f-439b-bf10-a074ed886bb7","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["a27a5c68-ea1b-411c-8430-0e28936f53d2"]},{"key":"dc:type","label":"Dc Type","values":["Text","Dissertation"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Liquid protection","Fusion","Thin films","Thermocapillary","Rupture","Dry-out"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Liquid films","Heat Convection","Fusion reactors"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/19837"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Thin liquid layers have been proposed for heat extraction and protection of the solid surfaces of divertors in magnetic fusion reactors. A number of conceptual designs for plasma-facing components (PFC) use stationary and flowing liquid layers as a renewable first wall for reactor chambers to remove heat and shield solid surfaces from damaging radiation while maintaining acceptable plasma purity levels. Such liquid-protected PFC have the potential to make fusion more commercially attractive by increasing reactor lifetimes and decreasing failure rates. The results of this research will help identify the parameter ranges for successful operation of such protection schemes. This thesis investigates the thermocapillary behavior of axisymmetric horizontal liquid layers with initial heights from 0.27 to 3.0 mm. A negative radial temperature gradient is imposed at the bottom of the liquid layer. Experimental, numerical and asymptotic analyses were carried out for thin layers where buoyancy forces are negligible. A novel asymptotic solution for this axisymmetric geometry was derived from the previous two-dimensional long-wave analysis by Sen et al. (1982). A numerical simulation using the level contour reconstruction method was used to follow the evolution of the liquid-gas interface above an axisymmetric non-isothermal solid surface. Experimental validation of the theoretical and numerical studies was performed using silicone oils of various viscosities (μ = 0.48 × 10-2 9.6 × 10-2 N s/m2). Two measurement techniques, a needle contact method and laser-confocal displacement method, were employed to obtain height profiles for applied temperature differences up to 65°C. Finally, reflectance shadowgraphy was used to visualize free-surface deformation and classify flow regimes in thick layers, where the assumptions of negligible buoyancy and axisymmetric flow are no longer valid. The results of this investigation will allow designers to determine operating windows for successful implementation of liquid-protected PFC."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph.D."]},{"key":"dc:title","label":"Title","values":["Experimental and Numerical Investigation of Thermocapillary Effects in Thin Liquid Layers"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Abdel-Khalik, Said I.","Yoda, Minami"],"dc:contributor.committeemember":["Aidun, Cyrus K.","Karl Jacob","Roman Grigoriev","Ghiaasiaan, S. Mostafa"],"dc:contributor.department":["Mechanical Engineering"],"dc:contributor.other":["George W. Woodruff School of Mechanical Engineering","College of Engineering"],"dc:creator":["Koehler, Timothy P."],"dc:date.accessioned":["2008-02-07T18:43:29Z"],"dc:date.available":["2008-02-07T18:43:29Z"],"dc:date.issued":["2007-10-02"],"dc:description.abstract":["Thin liquid layers have been proposed for heat extraction and protection of the solid surfaces of divertors in magnetic fusion reactors. A number of conceptual designs for plasma-facing components (PFC) use stationary and flowing liquid layers as a renewable first wall for reactor chambers to remove heat and shield solid surfaces from damaging radiation while maintaining acceptable plasma purity levels. Such liquid-protected PFC have the potential to make fusion more commercially attractive by increasing reactor lifetimes and decreasing failure rates. The results of this research will help identify the parameter ranges for successful operation of such protection schemes. This thesis investigates the thermocapillary behavior of axisymmetric horizontal liquid layers with initial heights from 0.27 to 3.0 mm. A negative radial temperature gradient is imposed at the bottom of the liquid layer. Experimental, numerical and asymptotic analyses were carried out for thin layers where buoyancy forces are negligible. A novel asymptotic solution for this axisymmetric geometry was derived from the previous two-dimensional long-wave analysis by Sen et al. (1982). A numerical simulation using the level contour reconstruction method was used to follow the evolution of the liquid-gas interface above an axisymmetric non-isothermal solid surface. Experimental validation of the theoretical and numerical studies was performed using silicone oils of various viscosities (μ = 0.48 × 10-2 9.6 × 10-2 N s/m2). Two measurement techniques, a needle contact method and laser-confocal displacement method, were employed to obtain height profiles for applied temperature differences up to 65°C. Finally, reflectance shadowgraphy was used to visualize free-surface deformation and classify flow regimes in thick layers, where the assumptions of negligible buoyancy and axisymmetric flow are no longer valid. The results of this investigation will allow designers to determine operating windows for successful implementation of liquid-protected PFC."],"dc:description.degree":["Ph.D."],"dc:identifier.uri":["http://hdl.handle.net/1853/19837"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["196f5fb4-8c6b-4b41-add5-06b1d33b971c","d318e6bc-95be-4fd2-bb0a-19fe480686df"],"dc:relation.ispartofseries":["Doctor of Philosophy with a Major in Mechanical Engineering"],"dc:relation.orgunit":["c01ff908-c25f-439b-bf10-a074ed886bb7","7c022d60-21d5-497c-b552-95e489a06569"],"dc:relation.seriesentity":["a27a5c68-ea1b-411c-8430-0e28936f53d2"],"dc:subject":["Liquid protection","Fusion","Thin films","Thermocapillary","Rupture","Dry-out"],"dc:subject.lcsh":["Liquid films","Heat Convection","Fusion reactors"],"dc:title":["Experimental and Numerical Investigation of Thermocapillary Effects in Thin Liquid Layers"],"dc:type":["Text","Dissertation"],"dspace:entity.type":["Publication"]},"updated_at":"2026-11-19T03:54:48Z"}