{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/24674"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/24674","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Atomic force microscopy study of nano-confined liquids","abstract":"In this thesis, we investigate the structural and dynamical properties of nano-confined liquids by means of a new AFM-based technique that has the ability to measure normal force, lateral force, and the distance between the AFM tip and the sample simultaneously. Thanks to the mechanical stability of our apparatus, a judicious choice, and a new mechanical drift analysis, we are able to measure the tip-sample distance with sub-angstrom resolution, all the way down to the last liquid layer.","abstract_html":"In this thesis, we investigate the structural and dynamical properties of nano-confined liquids by means of a new AFM-based technique that has the ability to measure normal force, lateral force, and the distance between the AFM tip and the sample simultaneously. Thanks to the mechanical stability of our apparatus, a judicious choice, and a new mechanical drift analysis, we are able to measure the tip-sample distance with sub-angstrom resolution, all the way down to the last liquid layer.","abstract_has_math":false,"creators":["Li, Tai-De"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Physics","school":null,"contributors":[],"advisors":["Riedo, Elisa"],"committee_chairs":[],"committee_members":["Davidovic, Dragomir","Goldman, Daniel I.","Landman, Uzi","Lyon, L. Andrew"],"year":2008,"date_issued":"2008-08-19","date_published":"2008-08-19","updated_at":"2026-11-19T04:14:06Z","subjects":["AFM","Nano-confiend liquids","Tribology","Rheology","Nanoelectromechanical systems","Nanostructured materials","Fluid dynamics","Fluid mechanics"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/24674","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/24674","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F24674","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Riedo, Elisa"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Davidovic, Dragomir","Goldman, Daniel I.","Landman, Uzi","Lyon, L. Andrew"]},{"key":"dc:contributor.department","label":"Department","values":["Physics"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["College of Sciences","School of Physics"]},{"key":"dc:creator","label":"Author","values":["Li, Tai-De"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2008-09-17T19:29:03Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2008-09-17T19:29:03Z"]},{"key":"dc:date.issued","label":"Date","values":["2008-08-19"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Doctor of Philosophy with a Major in Physics"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["85042be6-2d68-4e07-b384-e1f908fae48a","2ba39017-11f1-40f4-9bc5-66f17b8f1539"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["c1062152-d026-4fb3-84db-ceedbfbbbf56"]},{"key":"dc:type","label":"Dc Type","values":["Text","Dissertation"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["AFM","Nano-confiend liquids","Tribology","Rheology"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Nanoelectromechanical systems","Nanostructured materials","Fluid dynamics","Fluid mechanics"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/24674"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["In this thesis, we investigate the structural and dynamical properties of nano-confined liquids by means of a new AFM-based technique that has the ability to measure normal force, lateral force, and the distance between the AFM tip and the sample simultaneously. Thanks to the mechanical stability of our apparatus, a judicious choice, and a new mechanical drift analysis, we are able to measure the tip-sample distance with sub-angstrom resolution, all the way down to the last liquid layer."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph.D."]},{"key":"dc:title","label":"Title","values":["Atomic force microscopy study of nano-confined liquids"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Riedo, Elisa"],"dc:contributor.committeemember":["Davidovic, Dragomir","Goldman, Daniel I.","Landman, Uzi","Lyon, L. Andrew"],"dc:contributor.department":["Physics"],"dc:contributor.other":["College of Sciences","School of Physics"],"dc:creator":["Li, Tai-De"],"dc:date.accessioned":["2008-09-17T19:29:03Z"],"dc:date.available":["2008-09-17T19:29:03Z"],"dc:date.issued":["2008-08-19"],"dc:description.abstract":["In this thesis, we investigate the structural and dynamical properties of nano-confined liquids by means of a new AFM-based technique that has the ability to measure normal force, lateral force, and the distance between the AFM tip and the sample simultaneously. Thanks to the mechanical stability of our apparatus, a judicious choice, and a new mechanical drift analysis, we are able to measure the tip-sample distance with sub-angstrom resolution, all the way down to the last liquid layer."],"dc:description.degree":["Ph.D."],"dc:identifier.uri":["http://hdl.handle.net/1853/24674"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.ispartofseries":["Doctor of Philosophy with a Major in Physics"],"dc:relation.orgunit":["85042be6-2d68-4e07-b384-e1f908fae48a","2ba39017-11f1-40f4-9bc5-66f17b8f1539"],"dc:relation.seriesentity":["c1062152-d026-4fb3-84db-ceedbfbbbf56"],"dc:subject":["AFM","Nano-confiend liquids","Tribology","Rheology"],"dc:subject.lcsh":["Nanoelectromechanical systems","Nanostructured materials","Fluid dynamics","Fluid mechanics"],"dc:title":["Atomic force microscopy study of nano-confined liquids"],"dc:type":["Text","Dissertation"],"dspace:entity.type":["Publication"]},"updated_at":"2026-11-19T04:14:06Z"}