{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/24794"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/24794","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Characterization of air voids in fresh cement paste through ultrasonic nondestructive testing","abstract":"The objective of this research is the pursuit of a better characterization method for the air voids - particularly air-entrained voids - in fresh cement-based materials through the use of ultrasonics. The use of air-entraining agents (AEA's) to incorporate a stable network of air voids into fresh cement paste is common practice in the concrete industry. These particular air voids significantly improve durability of hardened cement paste through mitigation of stresses associated with freezing and thawing cycles. It is understood that the performance of entrained air voids in cement paste is dependent on their size and distribution, or spacing factor. However, conventional methods for qualifying air content, such as the Pressure, Volume, and Gravimetric Methods, only measure total air volume and cannot assess size or spacing. In this investigation, using matched pairs of transducers, ultrasonic pulses were transmitted through fresh cement paste specimens (0.0\\% up to 0.6\\% AEA by weight of cement). The received signals were recorded every five minutes during the first six hours and then every fifteen minutes thereafter. Analysis shows strong distinctions between specimens with and those without the AEA. Further research is needed into the distinctions among specimens with the AEA. However, the data suggest correlations between Vicat setting times, heat of hydration, and autogenous strain and ultrasonic metrics such as pulse velocity and peak frequency of the signal. The findings of this research should be most appropriate as a foundation for an inversion process and improved air-entrainment detection methods.","abstract_html":"The objective of this research is the pursuit of a better characterization method for the air voids - particularly air-entrained voids - in fresh cement-based materials through the use of ultrasonics. The use of air-entraining agents (AEA&#x27;s) to incorporate a stable network of air voids into fresh cement paste is common practice in the concrete industry. These particular air voids significantly improve durability of hardened cement paste through mitigation of stresses associated with freezing and thawing cycles. It is understood that the performance of entrained air voids in cement paste is dependent on their size and distribution, or spacing factor. However, conventional methods for qualifying air content, such as the Pressure, Volume, and Gravimetric Methods, only measure total air volume and cannot assess size or spacing. In this investigation, using matched pairs of transducers, ultrasonic pulses were transmitted through fresh cement paste specimens (0.0\\% up to 0.6\\% AEA by weight of cement). The received signals were recorded every five minutes during the first six hours and then every fifteen minutes thereafter. Analysis shows strong distinctions between specimens with and those without the AEA. Further research is needed into the distinctions among specimens with the AEA. However, the data suggest correlations between Vicat setting times, heat of hydration, and autogenous strain and ultrasonic metrics such as pulse velocity and peak frequency of the signal. The findings of this research should be most appropriate as a foundation for an inversion process and improved air-entrainment detection methods.","abstract_has_math":false,"creators":["Kmack, Richard Matthew"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Civil and Environmental Engineering","school":null,"contributors":[],"advisors":["Jacobs, Laurence J.","Kurtis, Kimberly E."],"committee_chairs":[],"committee_members":["DesRoches, Reginald"],"year":2008,"date_issued":"2008-07-10","date_published":"2008-07-10","updated_at":"2026-11-19T05:10:29Z","subjects":["Air-entrainment","Hydration","Paste","Cement","Cement Microstructure","Nondestructive testing","Ultrasonic testing","Cement Air entrainment"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/24794","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/24794","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F24794","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Jacobs, Laurence J.","Kurtis, Kimberly E."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["DesRoches, Reginald"]},{"key":"dc:contributor.department","label":"Department","values":["Civil and Environmental Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["School of Civil and Environmental Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Kmack, Richard Matthew"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2008-09-17T19:52:36Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2008-09-17T19:52:36Z"]},{"key":"dc:date.issued","label":"Date","values":["2008-07-10"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["5af40958-ece2-4a76-b071-5ba4c6d99d80","8c2a7a5c-9e70-4569-a98f-801c6d9e37be"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Master of Science in Engineering Science and Mechanics"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["88639fad-d3ae-4867-9e7a-7c9e6d2ecc7c","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["7a332c00-0af4-4db0-8d23-dbf522cc0e99"]},{"key":"dc:type","label":"Dc Type","values":["Text","Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Air-entrainment","Hydration","Paste","Cement"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Cement Microstructure","Nondestructive testing","Ultrasonic testing","Cement Air entrainment"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/24794"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The objective of this research is the pursuit of a better characterization method for the air voids - particularly air-entrained voids - in fresh cement-based materials through the use of ultrasonics. The use of air-entraining agents (AEA's) to incorporate a stable network of air voids into fresh cement paste is common practice in the concrete industry. These particular air voids significantly improve durability of hardened cement paste through mitigation of stresses associated with freezing and thawing cycles. It is understood that the performance of entrained air voids in cement paste is dependent on their size and distribution, or spacing factor. However, conventional methods for qualifying air content, such as the Pressure, Volume, and Gravimetric Methods, only measure total air volume and cannot assess size or spacing. In this investigation, using matched pairs of transducers, ultrasonic pulses were transmitted through fresh cement paste specimens (0.0\\% up to 0.6\\% AEA by weight of cement). The received signals were recorded every five minutes during the first six hours and then every fifteen minutes thereafter. Analysis shows strong distinctions between specimens with and those without the AEA. Further research is needed into the distinctions among specimens with the AEA. However, the data suggest correlations between Vicat setting times, heat of hydration, and autogenous strain and ultrasonic metrics such as pulse velocity and peak frequency of the signal. The findings of this research should be most appropriate as a foundation for an inversion process and improved air-entrainment detection methods."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.S."]},{"key":"dc:title","label":"Title","values":["Characterization of air voids in fresh cement paste through ultrasonic nondestructive testing"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Jacobs, Laurence J.","Kurtis, Kimberly E."],"dc:contributor.committeemember":["DesRoches, Reginald"],"dc:contributor.department":["Civil and Environmental Engineering"],"dc:contributor.other":["School of Civil and Environmental Engineering","College of Engineering"],"dc:creator":["Kmack, Richard Matthew"],"dc:date.accessioned":["2008-09-17T19:52:36Z"],"dc:date.available":["2008-09-17T19:52:36Z"],"dc:date.issued":["2008-07-10"],"dc:description.abstract":["The objective of this research is the pursuit of a better characterization method for the air voids - particularly air-entrained voids - in fresh cement-based materials through the use of ultrasonics. The use of air-entraining agents (AEA's) to incorporate a stable network of air voids into fresh cement paste is common practice in the concrete industry. These particular air voids significantly improve durability of hardened cement paste through mitigation of stresses associated with freezing and thawing cycles. It is understood that the performance of entrained air voids in cement paste is dependent on their size and distribution, or spacing factor. However, conventional methods for qualifying air content, such as the Pressure, Volume, and Gravimetric Methods, only measure total air volume and cannot assess size or spacing. In this investigation, using matched pairs of transducers, ultrasonic pulses were transmitted through fresh cement paste specimens (0.0\\% up to 0.6\\% AEA by weight of cement). The received signals were recorded every five minutes during the first six hours and then every fifteen minutes thereafter. Analysis shows strong distinctions between specimens with and those without the AEA. Further research is needed into the distinctions among specimens with the AEA. However, the data suggest correlations between Vicat setting times, heat of hydration, and autogenous strain and ultrasonic metrics such as pulse velocity and peak frequency of the signal. The findings of this research should be most appropriate as a foundation for an inversion process and improved air-entrainment detection methods."],"dc:description.degree":["M.S."],"dc:identifier.uri":["http://hdl.handle.net/1853/24794"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["5af40958-ece2-4a76-b071-5ba4c6d99d80","8c2a7a5c-9e70-4569-a98f-801c6d9e37be"],"dc:relation.ispartofseries":["Master of Science in Engineering Science and Mechanics"],"dc:relation.orgunit":["88639fad-d3ae-4867-9e7a-7c9e6d2ecc7c","7c022d60-21d5-497c-b552-95e489a06569"],"dc:relation.seriesentity":["7a332c00-0af4-4db0-8d23-dbf522cc0e99"],"dc:subject":["Air-entrainment","Hydration","Paste","Cement"],"dc:subject.lcsh":["Cement Microstructure","Nondestructive testing","Ultrasonic testing","Cement Air entrainment"],"dc:title":["Characterization of air voids in fresh cement paste through ultrasonic nondestructive testing"],"dc:type":["Text","Thesis"],"dspace:entity.type":["Publication"]},"updated_at":"2026-11-19T05:10:29Z"}