{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/24803"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/24803","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Hemodynamic investigation of the liver using magnetic resonance imaging and computational fluid dynamics","abstract":"Cirrhosis is a leading cause of death in the United States and has severe and costly complications. Because of the clinical significance of cirrhosis, it is important that noninvasive methods be developed to detect cirrhosis early and to monitor its progression with advancing liver disease. Previous studies on portal venous hemodynamics have been performed mainly with ultrasound with mixed results. Magnetic Resonance Imaging offers several advantages over ultrasound including acquisition of both high quality anatomical and hemodynamic information. Phase-Contrast MR was used to gather velocity data for the portal venous system. Methods were developed to perform registration, segmentation and isolation of the portal vein geometries and velocity data. Computational Fluid Dynamics was also employed to further investigate the flow within the portal vein. Velocity data for the portal vein, superior mesenteric vein, splenic vein and the right or left portal vein was acquired in varying numbers for both data sets. Even with the limited number of subjects a few parameters were significant. Patients with cirrhosis had a significantly increased portal vein area and a significantly decreased average velocity per liver volume and velocity variance. Patients with cirrhosis had a significantly increased splenic vein area and average flow rate per liver volume. While these results are preliminary due to small sample size, they are promising and require further investigation and more subjects including varying stages of disease.","abstract_html":"Cirrhosis is a leading cause of death in the United States and has severe and costly complications. Because of the clinical significance of cirrhosis, it is important that noninvasive methods be developed to detect cirrhosis early and to monitor its progression with advancing liver disease. Previous studies on portal venous hemodynamics have been performed mainly with ultrasound with mixed results. Magnetic Resonance Imaging offers several advantages over ultrasound including acquisition of both high quality anatomical and hemodynamic information. Phase-Contrast MR was used to gather velocity data for the portal venous system. Methods were developed to perform registration, segmentation and isolation of the portal vein geometries and velocity data. Computational Fluid Dynamics was also employed to further investigate the flow within the portal vein. Velocity data for the portal vein, superior mesenteric vein, splenic vein and the right or left portal vein was acquired in varying numbers for both data sets. Even with the limited number of subjects a few parameters were significant. Patients with cirrhosis had a significantly increased portal vein area and a significantly decreased average velocity per liver volume and velocity variance. Patients with cirrhosis had a significantly increased splenic vein area and average flow rate per liver volume. While these results are preliminary due to small sample size, they are promising and require further investigation and more subjects including varying stages of disease.","abstract_has_math":false,"creators":["George, Stephanie Marie"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Biomedical Engineering","school":null,"contributors":[],"advisors":["Giddens, Don P."],"committee_chairs":[],"committee_members":["Heffron, Thomas","Martin, Diego","Oshinski, John","Vito, Raymond"],"year":2008,"date_issued":"2008-07-02","date_published":"2008-07-02","updated_at":"2026-11-19T04:00:07Z","subjects":["Portal vein","Computational fluid dynamics","Magnetic resonance imaging","Cirrhosis","Hemodynamics","Liver Cirrhosis"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/24803","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/24803","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F24803","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Giddens, Don P."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Heffron, Thomas","Martin, Diego","Oshinski, John","Vito, Raymond"]},{"key":"dc:contributor.department","label":"Department","values":["Biomedical Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Wallace H. Coulter Department of Biomedical Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["George, Stephanie Marie"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2008-09-17T19:53:11Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2008-09-17T19:53:11Z"]},{"key":"dc:date.issued","label":"Date","values":["2008-07-02"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Doctor of Philosophy with a Major in Biomedical Engineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["da59be3c-3d0a-41da-91b9-ebe2ecc83b66","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["d85f9f1b-b2b5-4bca-81af-4515c5281e54"]},{"key":"dc:type","label":"Dc Type","values":["Text","Dissertation"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Portal vein","Computational fluid dynamics","Magnetic resonance imaging","Cirrhosis"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Hemodynamics","Magnetic resonance imaging","Computational fluid dynamics","Liver Cirrhosis"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/24803"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Cirrhosis is a leading cause of death in the United States and has severe and costly complications. Because of the clinical significance of cirrhosis, it is important that noninvasive methods be developed to detect cirrhosis early and to monitor its progression with advancing liver disease. Previous studies on portal venous hemodynamics have been performed mainly with ultrasound with mixed results. Magnetic Resonance Imaging offers several advantages over ultrasound including acquisition of both high quality anatomical and hemodynamic information. Phase-Contrast MR was used to gather velocity data for the portal venous system. Methods were developed to perform registration, segmentation and isolation of the portal vein geometries and velocity data. Computational Fluid Dynamics was also employed to further investigate the flow within the portal vein. Velocity data for the portal vein, superior mesenteric vein, splenic vein and the right or left portal vein was acquired in varying numbers for both data sets. Even with the limited number of subjects a few parameters were significant. Patients with cirrhosis had a significantly increased portal vein area and a significantly decreased average velocity per liver volume and velocity variance. Patients with cirrhosis had a significantly increased splenic vein area and average flow rate per liver volume. While these results are preliminary due to small sample size, they are promising and require further investigation and more subjects including varying stages of disease."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph.D."]},{"key":"dc:title","label":"Title","values":["Hemodynamic investigation of the liver using magnetic resonance imaging and computational fluid dynamics"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Giddens, Don P."],"dc:contributor.committeemember":["Heffron, Thomas","Martin, Diego","Oshinski, John","Vito, Raymond"],"dc:contributor.department":["Biomedical Engineering"],"dc:contributor.other":["Wallace H. Coulter Department of Biomedical Engineering","College of Engineering"],"dc:creator":["George, Stephanie Marie"],"dc:date.accessioned":["2008-09-17T19:53:11Z"],"dc:date.available":["2008-09-17T19:53:11Z"],"dc:date.issued":["2008-07-02"],"dc:description.abstract":["Cirrhosis is a leading cause of death in the United States and has severe and costly complications. Because of the clinical significance of cirrhosis, it is important that noninvasive methods be developed to detect cirrhosis early and to monitor its progression with advancing liver disease. Previous studies on portal venous hemodynamics have been performed mainly with ultrasound with mixed results. Magnetic Resonance Imaging offers several advantages over ultrasound including acquisition of both high quality anatomical and hemodynamic information. Phase-Contrast MR was used to gather velocity data for the portal venous system. Methods were developed to perform registration, segmentation and isolation of the portal vein geometries and velocity data. Computational Fluid Dynamics was also employed to further investigate the flow within the portal vein. Velocity data for the portal vein, superior mesenteric vein, splenic vein and the right or left portal vein was acquired in varying numbers for both data sets. Even with the limited number of subjects a few parameters were significant. Patients with cirrhosis had a significantly increased portal vein area and a significantly decreased average velocity per liver volume and velocity variance. Patients with cirrhosis had a significantly increased splenic vein area and average flow rate per liver volume. While these results are preliminary due to small sample size, they are promising and require further investigation and more subjects including varying stages of disease."],"dc:description.degree":["Ph.D."],"dc:identifier.uri":["http://hdl.handle.net/1853/24803"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.ispartofseries":["Doctor of Philosophy with a Major in Biomedical Engineering"],"dc:relation.orgunit":["da59be3c-3d0a-41da-91b9-ebe2ecc83b66","7c022d60-21d5-497c-b552-95e489a06569"],"dc:relation.seriesentity":["d85f9f1b-b2b5-4bca-81af-4515c5281e54"],"dc:subject":["Portal vein","Computational fluid dynamics","Magnetic resonance imaging","Cirrhosis"],"dc:subject.lcsh":["Hemodynamics","Magnetic resonance imaging","Computational fluid dynamics","Liver Cirrhosis"],"dc:title":["Hemodynamic investigation of the liver using magnetic resonance imaging and computational fluid dynamics"],"dc:type":["Text","Dissertation"],"dspace:entity.type":["Publication"]},"updated_at":"2026-11-19T04:00:07Z"}