{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/26495"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/26495","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Determining fixation stability of amd patients using predictive eye estimation regression","abstract":"Patients with macular degeneration (MD) often fixate with a preferred retinal locus (PRL). Eye movements made while fixating with the PRL (in MD patients) has been observed to be maladaptive compared to those made while fixating with the fovea (normal sighted individuals). For example, in MD patients, PRL eye movements negatively affect fixation stability and re-fixation precision; consequently creating difficulty in reading and limits to their execution of other everyday activities. Abnormal eye movements from the PRL affect research on the physiological adaptations to MD. Specifically, previous research on cortical reorganization using functional magnetic resonance imaging (fMRI), indicates a critical need to accurately determine a MD patient's point of gaze in order to better infer existence of cortical reorganization. Unfortunately, standard MR compatible hardware eye-tracking systems do not work well with these patients. Their reduction in fixation stability often overwhelms the tracking algorithms used by these systems. This research investigates the use of an existing magnetic resonance imaging (MRI) based technique called Predictive Eye Estimation Regression (PEER) to determine the point of gaze of MD patients and thus control for fixation instability. PEER makes use of the fluctuations in the MR signal caused by eye movements to identify position of gaze. Engineering adaptations such as temporal resolution and brain coverage were applied to tailor PEER to MD patients. Also participants were evaluated on different fixation protocols and the results compared to that of the micro-perimeter MP-1 to test the efficacy of PEER. The fixation stability results obtained from PEER were similar to that obtained from the eye tracking results of the micro-perimeter MP-1. However, PEER's point of gaze estimations was different from the MP-1's in the fixation tests. The difference in this result cannot be concluded to be specific to PEER. In order to resolve this issue, advancements to PEER by the inclusion of an eye tracker in the scanner to run concurrently with PEER could provide more evidence of PEER's reliability. In addition, increasing the diversity of AMD patients in terms of the different scotoma types will help provide a better estimate of PEER flexibility and robustness.","abstract_html":"Patients with macular degeneration (MD) often fixate with a preferred retinal locus (PRL). Eye movements made while fixating with the PRL (in MD patients) has been observed to be maladaptive compared to those made while fixating with the fovea (normal sighted individuals). For example, in MD patients, PRL eye movements negatively affect fixation stability and re-fixation precision; consequently creating difficulty in reading and limits to their execution of other everyday activities. Abnormal eye movements from the PRL affect research on the physiological adaptations to MD. Specifically, previous research on cortical reorganization using functional magnetic resonance imaging (fMRI), indicates a critical need to accurately determine a MD patient&#x27;s point of gaze in order to better infer existence of cortical reorganization. Unfortunately, standard MR compatible hardware eye-tracking systems do not work well with these patients. Their reduction in fixation stability often overwhelms the tracking algorithms used by these systems. This research investigates the use of an existing magnetic resonance imaging (MRI) based technique called Predictive Eye Estimation Regression (PEER) to determine the point of gaze of MD patients and thus control for fixation instability. PEER makes use of the fluctuations in the MR signal caused by eye movements to identify position of gaze. Engineering adaptations such as temporal resolution and brain coverage were applied to tailor PEER to MD patients. Also participants were evaluated on different fixation protocols and the results compared to that of the micro-perimeter MP-1 to test the efficacy of PEER. The fixation stability results obtained from PEER were similar to that obtained from the eye tracking results of the micro-perimeter MP-1. However, PEER&#x27;s point of gaze estimations was different from the MP-1&#x27;s in the fixation tests. The difference in this result cannot be concluded to be specific to PEER. In order to resolve this issue, advancements to PEER by the inclusion of an eye tracker in the scanner to run concurrently with PEER could provide more evidence of PEER&#x27;s reliability. In addition, increasing the diversity of AMD patients in terms of the different scotoma types will help provide a better estimate of PEER flexibility and robustness.","abstract_has_math":false,"creators":["Adelore, Temilade Adediwura"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Biomedical Engineering","school":null,"contributors":[],"advisors":["Schumacher, Eric H."],"committee_chairs":[],"committee_members":["Shella Keilholz","Stephen LaConte"],"year":2008,"date_issued":"2008-08-20","date_published":"2008-08-20","updated_at":"2026-11-19T06:01:03Z","subjects":["AMD (Age-related macular degeneration)","PEER (Predictive Eye Estimation Regression)","SVM (Support Vector Machine)","Retinal degeneration","Adaptation (Physiology)","Visual perception","Gaze","Eye Movements"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/26495","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/26495","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F26495","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Schumacher, Eric H."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Shella Keilholz","Stephen LaConte"]},{"key":"dc:contributor.department","label":"Department","values":["Biomedical Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Wallace H. Coulter Department of Biomedical Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Adelore, Temilade Adediwura"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2009-01-22T15:40:29Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2009-01-22T15:40:29Z"]},{"key":"dc:date.issued","label":"Date","values":["2008-08-20"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["c89f8e95-a923-4e01-b7b8-16cb56f7d99f"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Master of Science in Biomedical Engineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["da59be3c-3d0a-41da-91b9-ebe2ecc83b66","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["f9608e55-1fc9-4f5c-bc9b-027467e51c31"]},{"key":"dc:type","label":"Dc Type","values":["Text","Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["AMD (Age-related macular degeneration)","PEER (Predictive Eye Estimation Regression)","SVM (Support Vector Machine)"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Retinal degeneration","Adaptation (Physiology)","Visual perception","Gaze","Eye Movements"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/26495"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Patients with macular degeneration (MD) often fixate with a preferred retinal locus (PRL). Eye movements made while fixating with the PRL (in MD patients) has been observed to be maladaptive compared to those made while fixating with the fovea (normal sighted individuals). For example, in MD patients, PRL eye movements negatively affect fixation stability and re-fixation precision; consequently creating difficulty in reading and limits to their execution of other everyday activities. Abnormal eye movements from the PRL affect research on the physiological adaptations to MD. Specifically, previous research on cortical reorganization using functional magnetic resonance imaging (fMRI), indicates a critical need to accurately determine a MD patient's point of gaze in order to better infer existence of cortical reorganization. Unfortunately, standard MR compatible hardware eye-tracking systems do not work well with these patients. Their reduction in fixation stability often overwhelms the tracking algorithms used by these systems. This research investigates the use of an existing magnetic resonance imaging (MRI) based technique called Predictive Eye Estimation Regression (PEER) to determine the point of gaze of MD patients and thus control for fixation instability. PEER makes use of the fluctuations in the MR signal caused by eye movements to identify position of gaze. Engineering adaptations such as temporal resolution and brain coverage were applied to tailor PEER to MD patients. Also participants were evaluated on different fixation protocols and the results compared to that of the micro-perimeter MP-1 to test the efficacy of PEER. The fixation stability results obtained from PEER were similar to that obtained from the eye tracking results of the micro-perimeter MP-1. However, PEER's point of gaze estimations was different from the MP-1's in the fixation tests. The difference in this result cannot be concluded to be specific to PEER. In order to resolve this issue, advancements to PEER by the inclusion of an eye tracker in the scanner to run concurrently with PEER could provide more evidence of PEER's reliability. In addition, increasing the diversity of AMD patients in terms of the different scotoma types will help provide a better estimate of PEER flexibility and robustness."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.S."]},{"key":"dc:title","label":"Title","values":["Determining fixation stability of amd patients using predictive eye estimation regression"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Schumacher, Eric H."],"dc:contributor.committeemember":["Shella Keilholz","Stephen LaConte"],"dc:contributor.department":["Biomedical Engineering"],"dc:contributor.other":["Wallace H. Coulter Department of Biomedical Engineering","College of Engineering"],"dc:creator":["Adelore, Temilade Adediwura"],"dc:date.accessioned":["2009-01-22T15:40:29Z"],"dc:date.available":["2009-01-22T15:40:29Z"],"dc:date.issued":["2008-08-20"],"dc:description.abstract":["Patients with macular degeneration (MD) often fixate with a preferred retinal locus (PRL). Eye movements made while fixating with the PRL (in MD patients) has been observed to be maladaptive compared to those made while fixating with the fovea (normal sighted individuals). For example, in MD patients, PRL eye movements negatively affect fixation stability and re-fixation precision; consequently creating difficulty in reading and limits to their execution of other everyday activities. Abnormal eye movements from the PRL affect research on the physiological adaptations to MD. Specifically, previous research on cortical reorganization using functional magnetic resonance imaging (fMRI), indicates a critical need to accurately determine a MD patient's point of gaze in order to better infer existence of cortical reorganization. Unfortunately, standard MR compatible hardware eye-tracking systems do not work well with these patients. Their reduction in fixation stability often overwhelms the tracking algorithms used by these systems. This research investigates the use of an existing magnetic resonance imaging (MRI) based technique called Predictive Eye Estimation Regression (PEER) to determine the point of gaze of MD patients and thus control for fixation instability. PEER makes use of the fluctuations in the MR signal caused by eye movements to identify position of gaze. Engineering adaptations such as temporal resolution and brain coverage were applied to tailor PEER to MD patients. Also participants were evaluated on different fixation protocols and the results compared to that of the micro-perimeter MP-1 to test the efficacy of PEER. The fixation stability results obtained from PEER were similar to that obtained from the eye tracking results of the micro-perimeter MP-1. However, PEER's point of gaze estimations was different from the MP-1's in the fixation tests. The difference in this result cannot be concluded to be specific to PEER. In order to resolve this issue, advancements to PEER by the inclusion of an eye tracker in the scanner to run concurrently with PEER could provide more evidence of PEER's reliability. In addition, increasing the diversity of AMD patients in terms of the different scotoma types will help provide a better estimate of PEER flexibility and robustness."],"dc:description.degree":["M.S."],"dc:identifier.uri":["http://hdl.handle.net/1853/26495"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["c89f8e95-a923-4e01-b7b8-16cb56f7d99f"],"dc:relation.ispartofseries":["Master of Science in Biomedical Engineering"],"dc:relation.orgunit":["da59be3c-3d0a-41da-91b9-ebe2ecc83b66","7c022d60-21d5-497c-b552-95e489a06569"],"dc:relation.seriesentity":["f9608e55-1fc9-4f5c-bc9b-027467e51c31"],"dc:subject":["AMD (Age-related macular degeneration)","PEER (Predictive Eye Estimation Regression)","SVM (Support Vector Machine)"],"dc:subject.lcsh":["Retinal degeneration","Adaptation (Physiology)","Visual perception","Gaze","Eye Movements"],"dc:title":["Determining fixation stability of amd patients using predictive eye estimation regression"],"dc:type":["Text","Thesis"],"dspace:entity.type":["Publication"]},"updated_at":"2026-11-19T06:01:03Z"}