{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/28091"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/28091","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Evaluation of high strength lightweight concrete precast, prestressed bridge girders","abstract":"This thesis evaluates the use of High Strength Lightweight Concrete (HSLW) in bridge girders for the I-85 Ramp \"B\" Bridge crossing SR-34 in Cowetta County, Georgia. This bridge consisted of four spans; all girders were constructed using lightweight expanded slate aggregate. Spans 2 and 3 had a design strength of 10,000 psi, and span 2 was chosen for this research. The BT-54 girders were 107 ft 11½ inches in length. The prestressing strands used in these girders were 0.6 in diameter, grade 270, low relaxation strands. Material properties and member properties were tested. All 5 girders of span 2 were instrumented with vibrating wire strain gages at midspan, as well as with DEMEC inserts for transfer length measurements and with a deflection measurement system. Transfer length measurements found the transfer length of the girders to be 23% less than the values suggested by AASHTO and ACI equations. The deflection measurements showed 4.26 inches of camber at 56-days while the girders were stored at Standard Concrete Products. The camber measurements matched theoretical predictions within 5%. Mechanical property tests found the concrete to be within all design requirements. A stiffness, load test was performed on each of the 5 girders at Standard Concrete Products. The average stiffness value of 8.428 x 106 kip ft2 is recommend for use by GDOT engineers in designing the deck and road profile. This thesis discusses all short term findings from construction to the end of storage. A later report will address long term issues such as creep and shrinkage, as well as the performance of the girders as part of the bridge.","abstract_html":"This thesis evaluates the use of High Strength Lightweight Concrete (HSLW) in bridge girders for the I-85 Ramp &quot;B&quot; Bridge crossing SR-34 in Cowetta County, Georgia. This bridge consisted of four spans; all girders were constructed using lightweight expanded slate aggregate. Spans 2 and 3 had a design strength of 10,000 psi, and span 2 was chosen for this research. The BT-54 girders were 107 ft 11½ inches in length. The prestressing strands used in these girders were 0.6 in diameter, grade 270, low relaxation strands. Material properties and member properties were tested. All 5 girders of span 2 were instrumented with vibrating wire strain gages at midspan, as well as with DEMEC inserts for transfer length measurements and with a deflection measurement system. Transfer length measurements found the transfer length of the girders to be 23% less than the values suggested by AASHTO and ACI equations. The deflection measurements showed 4.26 inches of camber at 56-days while the girders were stored at Standard Concrete Products. The camber measurements matched theoretical predictions within 5%. Mechanical property tests found the concrete to be within all design requirements. A stiffness, load test was performed on each of the 5 girders at Standard Concrete Products. The average stiffness value of 8.428 x 106 kip ft2 is recommend for use by GDOT engineers in designing the deck and road profile. This thesis discusses all short term findings from construction to the end of storage. A later report will address long term issues such as creep and shrinkage, as well as the performance of the girders as part of the bridge.","abstract_has_math":false,"creators":["Dunbeck, Jennifer"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Civil and Environmental Engineering","school":null,"contributors":[],"advisors":["Kahn, Lawrence F."],"committee_chairs":[],"committee_members":["Castrodale, Reid","Kurtis, Kimberly"],"year":2009,"date_issued":"2009-04-08","date_published":"2009-04-08","updated_at":"2026-11-19T05:49:53Z","subjects":["Prestressed","Precast","Concrete","High strength","Lightweight","Girders","Bridges","High strength concrete","Lightweight concrete"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/28091","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/28091","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F28091","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Kahn, Lawrence F."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Castrodale, Reid","Kurtis, Kimberly"]},{"key":"dc:contributor.department","label":"Department","values":["Civil and Environmental Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["School of Civil and Environmental Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Dunbeck, Jennifer"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2009-06-08T18:43:35Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2009-06-08T18:43:35Z"]},{"key":"dc:date.issued","label":"Date","values":["2009-04-08"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["88639fad-d3ae-4867-9e7a-7c9e6d2ecc7c","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:type","label":"Dc Type","values":["Text","Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Prestressed","Precast","Concrete","High strength","Lightweight"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Girders","Bridges","High strength concrete","Lightweight concrete"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/28091"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This thesis evaluates the use of High Strength Lightweight Concrete (HSLW) in bridge girders for the I-85 Ramp \"B\" Bridge crossing SR-34 in Cowetta County, Georgia. This bridge consisted of four spans; all girders were constructed using lightweight expanded slate aggregate. Spans 2 and 3 had a design strength of 10,000 psi, and span 2 was chosen for this research. The BT-54 girders were 107 ft 11½ inches in length. The prestressing strands used in these girders were 0.6 in diameter, grade 270, low relaxation strands. Material properties and member properties were tested. All 5 girders of span 2 were instrumented with vibrating wire strain gages at midspan, as well as with DEMEC inserts for transfer length measurements and with a deflection measurement system. Transfer length measurements found the transfer length of the girders to be 23% less than the values suggested by AASHTO and ACI equations. The deflection measurements showed 4.26 inches of camber at 56-days while the girders were stored at Standard Concrete Products. The camber measurements matched theoretical predictions within 5%. Mechanical property tests found the concrete to be within all design requirements. A stiffness, load test was performed on each of the 5 girders at Standard Concrete Products. The average stiffness value of 8.428 x 106 kip ft2 is recommend for use by GDOT engineers in designing the deck and road profile. This thesis discusses all short term findings from construction to the end of storage. A later report will address long term issues such as creep and shrinkage, as well as the performance of the girders as part of the bridge."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.S."]},{"key":"dc:title","label":"Title","values":["Evaluation of high strength lightweight concrete precast, prestressed bridge girders"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Kahn, Lawrence F."],"dc:contributor.committeemember":["Castrodale, Reid","Kurtis, Kimberly"],"dc:contributor.department":["Civil and Environmental Engineering"],"dc:contributor.other":["School of Civil and Environmental Engineering","College of Engineering"],"dc:creator":["Dunbeck, Jennifer"],"dc:date.accessioned":["2009-06-08T18:43:35Z"],"dc:date.available":["2009-06-08T18:43:35Z"],"dc:date.issued":["2009-04-08"],"dc:description.abstract":["This thesis evaluates the use of High Strength Lightweight Concrete (HSLW) in bridge girders for the I-85 Ramp \"B\" Bridge crossing SR-34 in Cowetta County, Georgia. This bridge consisted of four spans; all girders were constructed using lightweight expanded slate aggregate. Spans 2 and 3 had a design strength of 10,000 psi, and span 2 was chosen for this research. The BT-54 girders were 107 ft 11½ inches in length. The prestressing strands used in these girders were 0.6 in diameter, grade 270, low relaxation strands. Material properties and member properties were tested. All 5 girders of span 2 were instrumented with vibrating wire strain gages at midspan, as well as with DEMEC inserts for transfer length measurements and with a deflection measurement system. Transfer length measurements found the transfer length of the girders to be 23% less than the values suggested by AASHTO and ACI equations. The deflection measurements showed 4.26 inches of camber at 56-days while the girders were stored at Standard Concrete Products. The camber measurements matched theoretical predictions within 5%. Mechanical property tests found the concrete to be within all design requirements. A stiffness, load test was performed on each of the 5 girders at Standard Concrete Products. The average stiffness value of 8.428 x 106 kip ft2 is recommend for use by GDOT engineers in designing the deck and road profile. This thesis discusses all short term findings from construction to the end of storage. A later report will address long term issues such as creep and shrinkage, as well as the performance of the girders as part of the bridge."],"dc:description.degree":["M.S."],"dc:identifier.uri":["http://hdl.handle.net/1853/28091"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.orgunit":["88639fad-d3ae-4867-9e7a-7c9e6d2ecc7c","7c022d60-21d5-497c-b552-95e489a06569"],"dc:subject":["Prestressed","Precast","Concrete","High strength","Lightweight"],"dc:subject.lcsh":["Girders","Bridges","High strength concrete","Lightweight concrete"],"dc:title":["Evaluation of high strength lightweight concrete precast, prestressed bridge girders"],"dc:type":["Text","Thesis"],"dspace:entity.type":["Publication"]},"updated_at":"2026-11-19T05:49:53Z"}