{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/28193"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/28193","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Sensing array for coherence analysis of modulated aquatic chemical plumes","abstract":"An electrochemical sensor array can provide information about the spatial and temporal distribution of chemicals in liquid turbulent plumes. Planar laser induced fluorescence (PLIF) and amperometric sensor arrays were used to record signals from modulated chemical plumes released into a recirculating aquatic flume. Coherence analysis was applied to extract the frequency components contained in the sensor response. Effects due to release distance, modulation frequency, and array orientation were investigated. This study has demonstrated that frequency encoded information can be extracted from a turbulent chemical plume using an array of amperometric sensors with optimized three-dimensional geometry and tuning.","abstract_html":"An electrochemical sensor array can provide information about the spatial and temporal distribution of chemicals in liquid turbulent plumes. Planar laser induced fluorescence (PLIF) and amperometric sensor arrays were used to record signals from modulated chemical plumes released into a recirculating aquatic flume. Coherence analysis was applied to extract the frequency components contained in the sensor response. Effects due to release distance, modulation frequency, and array orientation were investigated. This study has demonstrated that frequency encoded information can be extracted from a turbulent chemical plume using an array of amperometric sensors with optimized three-dimensional geometry and tuning.","abstract_has_math":false,"creators":["Cantor, Ryan Segler"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Chemistry and Biochemistry","school":null,"contributors":[],"advisors":["Janata, Jiří"],"committee_chairs":[],"committee_members":["Lyon, L. Andrew","Weissburg, Marc"],"year":2009,"date_issued":"2009-04-08","date_published":"2009-04-08","updated_at":"2026-11-19T05:01:40Z","subjects":["Chemical plume tracking","Electrochemical sensor array","Chemical detectors","Plumes (Fluid dynamics)","Eddies","Aquatic sciences","Coherence (Optics)"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/28193","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/28193","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F28193","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Janata, Jiří"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Lyon, L. Andrew","Weissburg, Marc"]},{"key":"dc:contributor.department","label":"Department","values":["Chemistry and Biochemistry"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["School of Chemistry and Biochemistry","College of Sciences"]},{"key":"dc:creator","label":"Author","values":["Cantor, Ryan Segler"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2009-06-08T19:22:11Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2009-06-08T19:22:11Z"]},{"key":"dc:date.issued","label":"Date","values":["2009-04-08"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["bdd9601d-9df0-4a6e-90dc-5e5b222dcee3"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Master of Science in Chemistry"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["f1725b93-3ab8-4c47-a4c3-3596c03d6f1e","85042be6-2d68-4e07-b384-e1f908fae48a"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["8954817e-f914-4a18-bccd-8e0ecaf17c10"]},{"key":"dc:type","label":"Dc Type","values":["Text","Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Chemical plume tracking","Electrochemical sensor array"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Chemical detectors","Plumes (Fluid dynamics)","Eddies","Aquatic sciences","Coherence (Optics)"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/28193"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["An electrochemical sensor array can provide information about the spatial and temporal distribution of chemicals in liquid turbulent plumes. Planar laser induced fluorescence (PLIF) and amperometric sensor arrays were used to record signals from modulated chemical plumes released into a recirculating aquatic flume. Coherence analysis was applied to extract the frequency components contained in the sensor response. Effects due to release distance, modulation frequency, and array orientation were investigated. This study has demonstrated that frequency encoded information can be extracted from a turbulent chemical plume using an array of amperometric sensors with optimized three-dimensional geometry and tuning."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.S."]},{"key":"dc:title","label":"Title","values":["Sensing array for coherence analysis of modulated aquatic chemical plumes"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Janata, Jiří"],"dc:contributor.committeemember":["Lyon, L. Andrew","Weissburg, Marc"],"dc:contributor.department":["Chemistry and Biochemistry"],"dc:contributor.other":["School of Chemistry and Biochemistry","College of Sciences"],"dc:creator":["Cantor, Ryan Segler"],"dc:date.accessioned":["2009-06-08T19:22:11Z"],"dc:date.available":["2009-06-08T19:22:11Z"],"dc:date.issued":["2009-04-08"],"dc:description.abstract":["An electrochemical sensor array can provide information about the spatial and temporal distribution of chemicals in liquid turbulent plumes. Planar laser induced fluorescence (PLIF) and amperometric sensor arrays were used to record signals from modulated chemical plumes released into a recirculating aquatic flume. Coherence analysis was applied to extract the frequency components contained in the sensor response. Effects due to release distance, modulation frequency, and array orientation were investigated. This study has demonstrated that frequency encoded information can be extracted from a turbulent chemical plume using an array of amperometric sensors with optimized three-dimensional geometry and tuning."],"dc:description.degree":["M.S."],"dc:identifier.uri":["http://hdl.handle.net/1853/28193"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["bdd9601d-9df0-4a6e-90dc-5e5b222dcee3"],"dc:relation.ispartofseries":["Master of Science in Chemistry"],"dc:relation.orgunit":["f1725b93-3ab8-4c47-a4c3-3596c03d6f1e","85042be6-2d68-4e07-b384-e1f908fae48a"],"dc:relation.seriesentity":["8954817e-f914-4a18-bccd-8e0ecaf17c10"],"dc:subject":["Chemical plume tracking","Electrochemical sensor array"],"dc:subject.lcsh":["Chemical detectors","Plumes (Fluid dynamics)","Eddies","Aquatic sciences","Coherence (Optics)"],"dc:title":["Sensing array for coherence analysis of modulated aquatic chemical plumes"],"dc:type":["Text","Thesis"],"dspace:entity.type":["Publication"]},"updated_at":"2026-11-19T05:01:40Z"}