{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/28210"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/28210","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Evaluation of performance and maximum length of continuous decks in simple-span bridges","abstract":"The purpose of this research was to evaluate the performance history of continuous bridge decks in the State of Georgia, to determine why the current design detail works, to recommend a new design detail if necessary, and to recommend the maximum and/or optimum lengths of continuous bridge decks. The continuous bridge decks have continuous reinforcement over the junction of two edge beams with a construction joint for crack control. The current technical literature and current practices and design procedures were synthesized and summarized. GDOT maintenance reports were reviewed, and field evaluations were conducted to determine the performance of the continuous deck detail. The effects of bridge movement due to thermal strains, shrinkage, and live loads were considered in the analytical studies to better understand the demands placed on the GDOT continuous deck detail. A summary of the design and length recommendations was provided upon completion of the research.","abstract_html":"The purpose of this research was to evaluate the performance history of continuous bridge decks in the State of Georgia, to determine why the current design detail works, to recommend a new design detail if necessary, and to recommend the maximum and/or optimum lengths of continuous bridge decks. The continuous bridge decks have continuous reinforcement over the junction of two edge beams with a construction joint for crack control. The current technical literature and current practices and design procedures were synthesized and summarized. GDOT maintenance reports were reviewed, and field evaluations were conducted to determine the performance of the continuous deck detail. The effects of bridge movement due to thermal strains, shrinkage, and live loads were considered in the analytical studies to better understand the demands placed on the GDOT continuous deck detail. A summary of the design and length recommendations was provided upon completion of the research.","abstract_has_math":false,"creators":["Snedeker, Katherine O."],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Civil and Environmental Engineering","school":null,"contributors":[],"advisors":["White, Donald W.","Kahn, Lawrence F."],"committee_chairs":[],"committee_members":["Leon, Roberto T."],"year":2009,"date_issued":"2009-04-08","date_published":"2009-04-08","updated_at":"2026-11-19T05:57:00Z","subjects":["Continuous bridge deck","Jointless bridge deck","Link slab","Bridges Floors","Strains and stresses","Continuous bridges"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/28210","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/28210","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F28210","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["White, Donald W.","Kahn, Lawrence F."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Leon, Roberto T."]},{"key":"dc:contributor.department","label":"Department","values":["Civil and Environmental Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["School of Civil and Environmental Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Snedeker, Katherine O."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2009-06-08T19:28:43Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2009-06-08T19:28:43Z"]},{"key":"dc:date.issued","label":"Date","values":["2009-04-08"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["0a43b47e-12ae-4081-a3ef-bf6c5eef1ef3"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Master of Science in Civil Engineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["88639fad-d3ae-4867-9e7a-7c9e6d2ecc7c","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["451ac1ce-0dd6-43a5-8843-bae81fd68e33"]},{"key":"dc:type","label":"Dc Type","values":["Text","Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Continuous bridge deck","Jointless bridge deck","Link slab"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Bridges Floors","Strains and stresses","Continuous bridges"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/28210"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The purpose of this research was to evaluate the performance history of continuous bridge decks in the State of Georgia, to determine why the current design detail works, to recommend a new design detail if necessary, and to recommend the maximum and/or optimum lengths of continuous bridge decks. The continuous bridge decks have continuous reinforcement over the junction of two edge beams with a construction joint for crack control. The current technical literature and current practices and design procedures were synthesized and summarized. GDOT maintenance reports were reviewed, and field evaluations were conducted to determine the performance of the continuous deck detail. The effects of bridge movement due to thermal strains, shrinkage, and live loads were considered in the analytical studies to better understand the demands placed on the GDOT continuous deck detail. A summary of the design and length recommendations was provided upon completion of the research."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.S."]},{"key":"dc:title","label":"Title","values":["Evaluation of performance and maximum length of continuous decks in simple-span bridges"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["White, Donald W.","Kahn, Lawrence F."],"dc:contributor.committeemember":["Leon, Roberto T."],"dc:contributor.department":["Civil and Environmental Engineering"],"dc:contributor.other":["School of Civil and Environmental Engineering","College of Engineering"],"dc:creator":["Snedeker, Katherine O."],"dc:date.accessioned":["2009-06-08T19:28:43Z"],"dc:date.available":["2009-06-08T19:28:43Z"],"dc:date.issued":["2009-04-08"],"dc:description.abstract":["The purpose of this research was to evaluate the performance history of continuous bridge decks in the State of Georgia, to determine why the current design detail works, to recommend a new design detail if necessary, and to recommend the maximum and/or optimum lengths of continuous bridge decks. The continuous bridge decks have continuous reinforcement over the junction of two edge beams with a construction joint for crack control. The current technical literature and current practices and design procedures were synthesized and summarized. GDOT maintenance reports were reviewed, and field evaluations were conducted to determine the performance of the continuous deck detail. The effects of bridge movement due to thermal strains, shrinkage, and live loads were considered in the analytical studies to better understand the demands placed on the GDOT continuous deck detail. A summary of the design and length recommendations was provided upon completion of the research."],"dc:description.degree":["M.S."],"dc:identifier.uri":["http://hdl.handle.net/1853/28210"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["0a43b47e-12ae-4081-a3ef-bf6c5eef1ef3"],"dc:relation.ispartofseries":["Master of Science in Civil Engineering"],"dc:relation.orgunit":["88639fad-d3ae-4867-9e7a-7c9e6d2ecc7c","7c022d60-21d5-497c-b552-95e489a06569"],"dc:relation.seriesentity":["451ac1ce-0dd6-43a5-8843-bae81fd68e33"],"dc:subject":["Continuous bridge deck","Jointless bridge deck","Link slab"],"dc:subject.lcsh":["Bridges Floors","Strains and stresses","Continuous bridges"],"dc:title":["Evaluation of performance and maximum length of continuous decks in simple-span bridges"],"dc:type":["Text","Thesis"],"dspace:entity.type":["Publication"]},"updated_at":"2026-11-19T05:57:00Z"}