{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/29607"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/29607","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Multiobjective optimization of contaminant sensor locations in drinking water distribution systems using nodal importance concepts","abstract":"The monitoring of water distribution systems (WDSs) has been a very popular subject of study since the terrorist attacks of September 11, 2001, and the subsequent passing of laws motivating the study of WDS monitoring to provide system protection in the event of a terrorist attack. Inhibiting many WDS monitoring studies to date is the large amount of computational expense required to conduct meaningful studies, especially for larger WDSs that are of most interest. In this study, methods were developed to determine the \"importance\" of WDS nodes in being considered as locations for sensors used to monitor a WDS in order to make sensor placement optimization more efficient. Single-objective protection goals considered individually in optimization were maximizing detection likelihood, minimizing expected detection time, and minimizing expected contaminated demand volume. A multiobjective protection goal accounting for all three single-objective goals concurrently was also considered; the formulation of the multiobjective optimization problem was intended to minimize tradeoffs among individual protection goals. Sensor placement optimization was carried out with the Iterative Subset Search Method (ISSM) employing genetic algorithms developed in this work; ISSM used nodal importance rankings to search a small subset of nodes for the optimal solution initially then broadened the search incrementally until convergence to a best solution occurred. To demonstrate the effectiveness of the methods developed, sensor placement was performed according to each of the protection goals for three study systems--one small and two large--and a variety of attack conditions. Desirable sensor node solutions that provided for significant protection were found in all cases, and in many cases sensor placement results were comparable to or better than those of other works. Nodal importance narrowed the search for optimal sensor nodes to a relatively small proportion of WDS nodes in most cases.","abstract_html":"The monitoring of water distribution systems (WDSs) has been a very popular subject of study since the terrorist attacks of September 11, 2001, and the subsequent passing of laws motivating the study of WDS monitoring to provide system protection in the event of a terrorist attack. Inhibiting many WDS monitoring studies to date is the large amount of computational expense required to conduct meaningful studies, especially for larger WDSs that are of most interest. In this study, methods were developed to determine the &quot;importance&quot; of WDS nodes in being considered as locations for sensors used to monitor a WDS in order to make sensor placement optimization more efficient. Single-objective protection goals considered individually in optimization were maximizing detection likelihood, minimizing expected detection time, and minimizing expected contaminated demand volume. A multiobjective protection goal accounting for all three single-objective goals concurrently was also considered; the formulation of the multiobjective optimization problem was intended to minimize tradeoffs among individual protection goals. Sensor placement optimization was carried out with the Iterative Subset Search Method (ISSM) employing genetic algorithms developed in this work; ISSM used nodal importance rankings to search a small subset of nodes for the optimal solution initially then broadened the search incrementally until convergence to a best solution occurred. To demonstrate the effectiveness of the methods developed, sensor placement was performed according to each of the protection goals for three study systems--one small and two large--and a variety of attack conditions. Desirable sensor node solutions that provided for significant protection were found in all cases, and in many cases sensor placement results were comparable to or better than those of other works. Nodal importance narrowed the search for optimal sensor nodes to a relatively small proportion of WDS nodes in most cases.","abstract_has_math":false,"creators":["Rogers, Scott W."],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Civil and Environmental Engineering","school":null,"contributors":[],"advisors":["Aral, Mustafa M."],"committee_chairs":[],"committee_members":["Guan, Jiabao","Jang, Wonyong","Kim, Seong-Hee","Uzer, Turgay"],"year":2009,"date_issued":"2009-05-18","date_published":"2009-05-18","updated_at":"2026-11-19T05:50:56Z","subjects":["Water distribution systems","Monitoring","Nodal importance","Drinking water treatment units","Chemical detectors","Mathematical optimization"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/29607","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/29607","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F29607","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Aral, Mustafa M."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Guan, Jiabao","Jang, Wonyong","Kim, Seong-Hee","Uzer, Turgay"]},{"key":"dc:contributor.department","label":"Department","values":["Civil and Environmental Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["School of Civil and Environmental Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Rogers, Scott W."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2009-08-26T17:30:27Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2009-08-26T17:30:27Z"]},{"key":"dc:date.issued","label":"Date","values":["2009-05-18"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Doctor of Philosophy with a Major in Environmental Engineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["88639fad-d3ae-4867-9e7a-7c9e6d2ecc7c","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["917773af-f8cc-48f6-91c6-c6cae016a587"]},{"key":"dc:type","label":"Dc Type","values":["Text","Dissertation"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Water distribution systems","Monitoring","Nodal importance"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Drinking water treatment units","Chemical detectors","Mathematical optimization"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/29607"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The monitoring of water distribution systems (WDSs) has been a very popular subject of study since the terrorist attacks of September 11, 2001, and the subsequent passing of laws motivating the study of WDS monitoring to provide system protection in the event of a terrorist attack. Inhibiting many WDS monitoring studies to date is the large amount of computational expense required to conduct meaningful studies, especially for larger WDSs that are of most interest. In this study, methods were developed to determine the \"importance\" of WDS nodes in being considered as locations for sensors used to monitor a WDS in order to make sensor placement optimization more efficient. Single-objective protection goals considered individually in optimization were maximizing detection likelihood, minimizing expected detection time, and minimizing expected contaminated demand volume. A multiobjective protection goal accounting for all three single-objective goals concurrently was also considered; the formulation of the multiobjective optimization problem was intended to minimize tradeoffs among individual protection goals. Sensor placement optimization was carried out with the Iterative Subset Search Method (ISSM) employing genetic algorithms developed in this work; ISSM used nodal importance rankings to search a small subset of nodes for the optimal solution initially then broadened the search incrementally until convergence to a best solution occurred. To demonstrate the effectiveness of the methods developed, sensor placement was performed according to each of the protection goals for three study systems--one small and two large--and a variety of attack conditions. Desirable sensor node solutions that provided for significant protection were found in all cases, and in many cases sensor placement results were comparable to or better than those of other works. Nodal importance narrowed the search for optimal sensor nodes to a relatively small proportion of WDS nodes in most cases."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph.D."]},{"key":"dc:title","label":"Title","values":["Multiobjective optimization of contaminant sensor locations in drinking water distribution systems using nodal importance concepts"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Aral, Mustafa M."],"dc:contributor.committeemember":["Guan, Jiabao","Jang, Wonyong","Kim, Seong-Hee","Uzer, Turgay"],"dc:contributor.department":["Civil and Environmental Engineering"],"dc:contributor.other":["School of Civil and Environmental Engineering","College of Engineering"],"dc:creator":["Rogers, Scott W."],"dc:date.accessioned":["2009-08-26T17:30:27Z"],"dc:date.available":["2009-08-26T17:30:27Z"],"dc:date.issued":["2009-05-18"],"dc:description.abstract":["The monitoring of water distribution systems (WDSs) has been a very popular subject of study since the terrorist attacks of September 11, 2001, and the subsequent passing of laws motivating the study of WDS monitoring to provide system protection in the event of a terrorist attack. Inhibiting many WDS monitoring studies to date is the large amount of computational expense required to conduct meaningful studies, especially for larger WDSs that are of most interest. In this study, methods were developed to determine the \"importance\" of WDS nodes in being considered as locations for sensors used to monitor a WDS in order to make sensor placement optimization more efficient. Single-objective protection goals considered individually in optimization were maximizing detection likelihood, minimizing expected detection time, and minimizing expected contaminated demand volume. A multiobjective protection goal accounting for all three single-objective goals concurrently was also considered; the formulation of the multiobjective optimization problem was intended to minimize tradeoffs among individual protection goals. Sensor placement optimization was carried out with the Iterative Subset Search Method (ISSM) employing genetic algorithms developed in this work; ISSM used nodal importance rankings to search a small subset of nodes for the optimal solution initially then broadened the search incrementally until convergence to a best solution occurred. To demonstrate the effectiveness of the methods developed, sensor placement was performed according to each of the protection goals for three study systems--one small and two large--and a variety of attack conditions. Desirable sensor node solutions that provided for significant protection were found in all cases, and in many cases sensor placement results were comparable to or better than those of other works. Nodal importance narrowed the search for optimal sensor nodes to a relatively small proportion of WDS nodes in most cases."],"dc:description.degree":["Ph.D."],"dc:identifier.uri":["http://hdl.handle.net/1853/29607"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.ispartofseries":["Doctor of Philosophy with a Major in Environmental Engineering"],"dc:relation.orgunit":["88639fad-d3ae-4867-9e7a-7c9e6d2ecc7c","7c022d60-21d5-497c-b552-95e489a06569"],"dc:relation.seriesentity":["917773af-f8cc-48f6-91c6-c6cae016a587"],"dc:subject":["Water distribution systems","Monitoring","Nodal importance"],"dc:subject.lcsh":["Drinking water treatment units","Chemical detectors","Mathematical optimization"],"dc:title":["Multiobjective optimization of contaminant sensor locations in drinking water distribution systems using nodal importance concepts"],"dc:type":["Text","Dissertation"],"dspace:entity.type":["Publication"]},"updated_at":"2026-11-19T05:50:56Z"}