{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/31696"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/31696","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"A Coarse Mesh Transport Method with general source treatment for medical physics","abstract":"The Coarse-Mesh Transport Method (COMET) is a method developed by the Computational Reactor and Medical Physics Group at Georgia Tech. Its original application was neutron transport for nuclear reactor modeling. COMET has since been shown to be effective for coupled photon-electron transport calculations where the goal is to determine the energy deposition of a photon beam. So far COMET can simulate a mono-directional, mono-energetic, spatially-flat photon beam. The goal of this thesis will be to extend COMET by adding a generalized source treatment. The new source will be able to simulate beams that vary in intensity as a function of position, angle, and energy. EGSnrc will be used to verify the accuracy of the new method for 3D photon kerma calculations.","abstract_html":"The Coarse-Mesh Transport Method (COMET) is a method developed by the Computational Reactor and Medical Physics Group at Georgia Tech. Its original application was neutron transport for nuclear reactor modeling. COMET has since been shown to be effective for coupled photon-electron transport calculations where the goal is to determine the energy deposition of a photon beam. So far COMET can simulate a mono-directional, mono-energetic, spatially-flat photon beam. The goal of this thesis will be to extend COMET by adding a generalized source treatment. The new source will be able to simulate beams that vary in intensity as a function of position, angle, and energy. EGSnrc will be used to verify the accuracy of the new method for 3D photon kerma calculations.","abstract_has_math":false,"creators":["Hayward, Robert M."],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Nuclear and Radiological Engineering","school":null,"contributors":[],"advisors":["Rahnema, Farzad"],"committee_chairs":[],"committee_members":["Wang, Chris","Zhang, Dingkang"],"year":2009,"date_issued":"2009-11-17","date_published":"2009-11-17","updated_at":"2026-11-19T05:17:02Z","subjects":["Photon transport","Dose calculation","Kerma calculation","Monte Carlo","Medical physics","Neutron transport theory","Nuclear reactors Mathematical models","Photon transport theory"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/31696","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/31696","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F31696","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Rahnema, Farzad"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Wang, Chris","Zhang, Dingkang"]},{"key":"dc:contributor.department","label":"Department","values":["Nuclear and Radiological Engineering","Medical Physics"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["George W. Woodruff School of Mechanical Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Hayward, Robert M."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2010-01-29T19:42:38Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2010-01-29T19:42:38Z"]},{"key":"dc:date.issued","label":"Date","values":["2009-11-17"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["1d96b222-d2f0-46d1-a0c7-4d1f9254dfab"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Master of Science in Medical Physics"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["c01ff908-c25f-439b-bf10-a074ed886bb7","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["3173665c-cfb8-400b-bcf7-8fbfc614e0fb"]},{"key":"dc:type","label":"Dc Type","values":["Text","Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Photon transport","Dose calculation","Kerma calculation","Monte Carlo"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Medical physics","Neutron transport theory","Nuclear reactors Mathematical models","Photon transport theory"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/31696"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The Coarse-Mesh Transport Method (COMET) is a method developed by the Computational Reactor and Medical Physics Group at Georgia Tech. Its original application was neutron transport for nuclear reactor modeling. COMET has since been shown to be effective for coupled photon-electron transport calculations where the goal is to determine the energy deposition of a photon beam. So far COMET can simulate a mono-directional, mono-energetic, spatially-flat photon beam. The goal of this thesis will be to extend COMET by adding a generalized source treatment. The new source will be able to simulate beams that vary in intensity as a function of position, angle, and energy. EGSnrc will be used to verify the accuracy of the new method for 3D photon kerma calculations."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.S."]},{"key":"dc:title","label":"Title","values":["A Coarse Mesh Transport Method with general source treatment for medical physics"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Rahnema, Farzad"],"dc:contributor.committeemember":["Wang, Chris","Zhang, Dingkang"],"dc:contributor.department":["Nuclear and Radiological Engineering","Medical Physics"],"dc:contributor.other":["George W. Woodruff School of Mechanical Engineering","College of Engineering"],"dc:creator":["Hayward, Robert M."],"dc:date.accessioned":["2010-01-29T19:42:38Z"],"dc:date.available":["2010-01-29T19:42:38Z"],"dc:date.issued":["2009-11-17"],"dc:description.abstract":["The Coarse-Mesh Transport Method (COMET) is a method developed by the Computational Reactor and Medical Physics Group at Georgia Tech. Its original application was neutron transport for nuclear reactor modeling. COMET has since been shown to be effective for coupled photon-electron transport calculations where the goal is to determine the energy deposition of a photon beam. So far COMET can simulate a mono-directional, mono-energetic, spatially-flat photon beam. The goal of this thesis will be to extend COMET by adding a generalized source treatment. The new source will be able to simulate beams that vary in intensity as a function of position, angle, and energy. EGSnrc will be used to verify the accuracy of the new method for 3D photon kerma calculations."],"dc:description.degree":["M.S."],"dc:identifier.uri":["http://hdl.handle.net/1853/31696"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["1d96b222-d2f0-46d1-a0c7-4d1f9254dfab"],"dc:relation.ispartofseries":["Master of Science in Medical Physics"],"dc:relation.orgunit":["c01ff908-c25f-439b-bf10-a074ed886bb7","7c022d60-21d5-497c-b552-95e489a06569"],"dc:relation.seriesentity":["3173665c-cfb8-400b-bcf7-8fbfc614e0fb"],"dc:subject":["Photon transport","Dose calculation","Kerma calculation","Monte Carlo"],"dc:subject.lcsh":["Medical physics","Neutron transport theory","Nuclear reactors Mathematical models","Photon transport theory"],"dc:title":["A Coarse Mesh Transport Method with general source treatment for medical physics"],"dc:type":["Text","Thesis"],"dspace:entity.type":["Publication"]},"updated_at":"2026-11-19T05:17:02Z"}