{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/33807"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/33807","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"A multi-stack framework in magnetic resonance imaging","abstract":"Magnetic resonance imaging (MRI) is the preferred imaging modality for visualization of intracranial soft tissues. Surgical planning, and increasingly surgical navigation, use high resolution 3-D patient-specific structural maps of the brain. However, the process of MRI is a multi-parameter tomographic technique where high resolution imagery competes against high contrast and reasonable acquisition times. Resolution enhancement techniques based on super-resolution are particularly well suited in solving the problems of resolution when high contrast with reasonable times for MRI acquisitions are needed. Super-resolution is the concept of reconstructing a high resolution image from a set of low-resolution images taken at dierent viewpoints or foci. The MRI encoding techniques that produce high resolution imagery are often sub-optimal for the desired contrast needed for visualization of some structures in the brain. A novel super-resolution reconstruction framework for MRI is proposed in this thesis. Its purpose is to produce images of both high resolution and high contrast desirable for image-guided minimally invasive brain surgery. The input data are multiple 2-D multi-slice Inversion Recovery MRI scans acquired at orientations with regular angular spacing rotated around a common axis. Inspired by the computed tomography domain, the reconstruction is a 3-D volume of isotropic high resolution, where the inversion process resembles a projection reconstruction problem. Iterative algorithms for reconstruction are based on the projection onto convex sets formalism. Results demonstrate resolution enhancement in simulated phantom studies, and in ex- and in-vivo human brain scans, carried out on clinical scanners. In addition, a novel motion correction method is applied to volume registration using an iterative technique in which super-resolution reconstruction is estimated in a given iteration following motion correction in the preceding iteration. A comparison study of our method with previously published methods in super-resolution shows favorable characteristics of the proposed approach.","abstract_html":"Magnetic resonance imaging (MRI) is the preferred imaging modality for visualization of intracranial soft tissues. Surgical planning, and increasingly surgical navigation, use high resolution 3-D patient-specific structural maps of the brain. However, the process of MRI is a multi-parameter tomographic technique where high resolution imagery competes against high contrast and reasonable acquisition times. Resolution enhancement techniques based on super-resolution are particularly well suited in solving the problems of resolution when high contrast with reasonable times for MRI acquisitions are needed. Super-resolution is the concept of reconstructing a high resolution image from a set of low-resolution images taken at dierent viewpoints or foci. The MRI encoding techniques that produce high resolution imagery are often sub-optimal for the desired contrast needed for visualization of some structures in the brain. A novel super-resolution reconstruction framework for MRI is proposed in this thesis. Its purpose is to produce images of both high resolution and high contrast desirable for image-guided minimally invasive brain surgery. The input data are multiple 2-D multi-slice Inversion Recovery MRI scans acquired at orientations with regular angular spacing rotated around a common axis. Inspired by the computed tomography domain, the reconstruction is a 3-D volume of isotropic high resolution, where the inversion process resembles a projection reconstruction problem. Iterative algorithms for reconstruction are based on the projection onto convex sets formalism. Results demonstrate resolution enhancement in simulated phantom studies, and in ex- and in-vivo human brain scans, carried out on clinical scanners. In addition, a novel motion correction method is applied to volume registration using an iterative technique in which super-resolution reconstruction is estimated in a given iteration following motion correction in the preceding iteration. A comparison study of our method with previously published methods in super-resolution shows favorable characteristics of the proposed approach.","abstract_has_math":false,"creators":["Shilling, Richard Zethward"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Electrical and Computer Engineering","school":null,"contributors":[],"advisors":["Mersereau, Russell M.","Brummer, Marijn E."],"committee_chairs":[],"committee_members":["Aaron D. Lanterman","Allen Tannenbaum","John Oshinski","Justin Romberg"],"year":2009,"date_issued":"2009-04-02","date_published":"2009-04-02","updated_at":"2026-11-19T05:06:05Z","subjects":["Image processing","Inverse problems","Super-resolution","Image reconstruction","MRI","Magnetic resonance imaging","High resolution imaging","Time","Contrast-enhanced magnetic resonance imaging","Tomography"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/33807","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/33807","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F33807","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Mersereau, Russell M.","Brummer, Marijn E."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Aaron D. Lanterman","Allen Tannenbaum","John Oshinski","Justin Romberg"]},{"key":"dc:contributor.department","label":"Department","values":["Electrical and Computer Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["School of Electrical and Computer Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Shilling, Richard Zethward"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2010-06-10T15:10:06Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2010-06-10T15:10:06Z"]},{"key":"dc:date.issued","label":"Date","values":["2009-04-02"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Doctor of Philosophy with a Major in Electrical and Computer Engineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["5b7adef2-447c-4270-b9fc-846bd76f80f2","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["3890cd56-8ecf-424b-8074-8f5ebd8dbe15"]},{"key":"dc:type","label":"Dc Type","values":["Text","Dissertation"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Image processing","Inverse problems","Super-resolution","Image reconstruction","MRI"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Magnetic resonance imaging","High resolution imaging","Time","Contrast-enhanced magnetic resonance imaging","Image reconstruction","Tomography"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/33807"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Magnetic resonance imaging (MRI) is the preferred imaging modality for visualization of intracranial soft tissues. Surgical planning, and increasingly surgical navigation, use high resolution 3-D patient-specific structural maps of the brain. However, the process of MRI is a multi-parameter tomographic technique where high resolution imagery competes against high contrast and reasonable acquisition times. Resolution enhancement techniques based on super-resolution are particularly well suited in solving the problems of resolution when high contrast with reasonable times for MRI acquisitions are needed. Super-resolution is the concept of reconstructing a high resolution image from a set of low-resolution images taken at dierent viewpoints or foci. The MRI encoding techniques that produce high resolution imagery are often sub-optimal for the desired contrast needed for visualization of some structures in the brain. A novel super-resolution reconstruction framework for MRI is proposed in this thesis. Its purpose is to produce images of both high resolution and high contrast desirable for image-guided minimally invasive brain surgery. The input data are multiple 2-D multi-slice Inversion Recovery MRI scans acquired at orientations with regular angular spacing rotated around a common axis. Inspired by the computed tomography domain, the reconstruction is a 3-D volume of isotropic high resolution, where the inversion process resembles a projection reconstruction problem. Iterative algorithms for reconstruction are based on the projection onto convex sets formalism. Results demonstrate resolution enhancement in simulated phantom studies, and in ex- and in-vivo human brain scans, carried out on clinical scanners. In addition, a novel motion correction method is applied to volume registration using an iterative technique in which super-resolution reconstruction is estimated in a given iteration following motion correction in the preceding iteration. A comparison study of our method with previously published methods in super-resolution shows favorable characteristics of the proposed approach."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph.D."]},{"key":"dc:title","label":"Title","values":["A multi-stack framework in magnetic resonance imaging"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Mersereau, Russell M.","Brummer, Marijn E."],"dc:contributor.committeemember":["Aaron D. Lanterman","Allen Tannenbaum","John Oshinski","Justin Romberg"],"dc:contributor.department":["Electrical and Computer Engineering"],"dc:contributor.other":["School of Electrical and Computer Engineering","College of Engineering"],"dc:creator":["Shilling, Richard Zethward"],"dc:date.accessioned":["2010-06-10T15:10:06Z"],"dc:date.available":["2010-06-10T15:10:06Z"],"dc:date.issued":["2009-04-02"],"dc:description.abstract":["Magnetic resonance imaging (MRI) is the preferred imaging modality for visualization of intracranial soft tissues. Surgical planning, and increasingly surgical navigation, use high resolution 3-D patient-specific structural maps of the brain. However, the process of MRI is a multi-parameter tomographic technique where high resolution imagery competes against high contrast and reasonable acquisition times. Resolution enhancement techniques based on super-resolution are particularly well suited in solving the problems of resolution when high contrast with reasonable times for MRI acquisitions are needed. Super-resolution is the concept of reconstructing a high resolution image from a set of low-resolution images taken at dierent viewpoints or foci. The MRI encoding techniques that produce high resolution imagery are often sub-optimal for the desired contrast needed for visualization of some structures in the brain. A novel super-resolution reconstruction framework for MRI is proposed in this thesis. Its purpose is to produce images of both high resolution and high contrast desirable for image-guided minimally invasive brain surgery. The input data are multiple 2-D multi-slice Inversion Recovery MRI scans acquired at orientations with regular angular spacing rotated around a common axis. Inspired by the computed tomography domain, the reconstruction is a 3-D volume of isotropic high resolution, where the inversion process resembles a projection reconstruction problem. Iterative algorithms for reconstruction are based on the projection onto convex sets formalism. Results demonstrate resolution enhancement in simulated phantom studies, and in ex- and in-vivo human brain scans, carried out on clinical scanners. In addition, a novel motion correction method is applied to volume registration using an iterative technique in which super-resolution reconstruction is estimated in a given iteration following motion correction in the preceding iteration. A comparison study of our method with previously published methods in super-resolution shows favorable characteristics of the proposed approach."],"dc:description.degree":["Ph.D."],"dc:identifier.uri":["http://hdl.handle.net/1853/33807"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.ispartofseries":["Doctor of Philosophy with a Major in Electrical and Computer Engineering"],"dc:relation.orgunit":["5b7adef2-447c-4270-b9fc-846bd76f80f2","7c022d60-21d5-497c-b552-95e489a06569"],"dc:relation.seriesentity":["3890cd56-8ecf-424b-8074-8f5ebd8dbe15"],"dc:subject":["Image processing","Inverse problems","Super-resolution","Image reconstruction","MRI"],"dc:subject.lcsh":["Magnetic resonance imaging","High resolution imaging","Time","Contrast-enhanced magnetic resonance imaging","Image reconstruction","Tomography"],"dc:title":["A multi-stack framework in magnetic resonance imaging"],"dc:type":["Text","Dissertation"],"dspace:entity.type":["Publication"]},"updated_at":"2026-11-19T05:06:05Z"}