{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/33853"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/33853","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Atlanta PM₂. ₅, 1999-2008: asaca data trends, quality, and application to ion sensitivity analysis","abstract":"Beginning in March 1999 at Georgia Institute of Technology, the ASACA (Assessment of Spatial Aerosol Composition in Atlanta) program has provided PM₂. ₅ concentration and speciation using particle concentration monitoring in and around metropolitan Atlanta. Since 1999, three of the ASACA sites have collected PM₂. ₅ in an urban setting: Fort McPherson (FT, SW), South Dekalb (SD, SE), and Tucker (TU, NE). In January 2007, TU was retired and Fire Station 8 (FS8, NE) was employed as the new urban site. Starting in 2002, PM₂. ₅ concentrations have also been characterized at a rural site, Fort Yargo (YG). Water-soluble ionic species and carbonaceous species concentrations are collected daily on filters using a three-channel particulate composition monitor (PCM). From 1999 to 2008, average PM₂. ₅ concentrations range from 12.9 µg/m3 at YG to 15.4 µg/m3 at TU. Sulfate and organic matter are the main components of Atlanta PM, contributing around 26% and 31% respectively to PM mass. Overall ASACA data quality increased from around 5 in 1999 to a value of 9 in 2005. Seasonal PM data quality appears to be significantly affected by volatility of secondary aerosol species during warm months because ionic data quality regularly decreases in the summer. PM is more sensitive to total sulfate concentration than nitrate and ammonia year-round.","abstract_html":"Beginning in March 1999 at Georgia Institute of Technology, the ASACA (Assessment of Spatial Aerosol Composition in Atlanta) program has provided PM₂. ₅ concentration and speciation using particle concentration monitoring in and around metropolitan Atlanta. Since 1999, three of the ASACA sites have collected PM₂. ₅ in an urban setting: Fort McPherson (FT, SW), South Dekalb (SD, SE), and Tucker (TU, NE). In January 2007, TU was retired and Fire Station 8 (FS8, NE) was employed as the new urban site. Starting in 2002, PM₂. ₅ concentrations have also been characterized at a rural site, Fort Yargo (YG). Water-soluble ionic species and carbonaceous species concentrations are collected daily on filters using a three-channel particulate composition monitor (PCM). From 1999 to 2008, average PM₂. ₅ concentrations range from 12.9 µg/m3 at YG to 15.4 µg/m3 at TU. Sulfate and organic matter are the main components of Atlanta PM, contributing around 26% and 31% respectively to PM mass. Overall ASACA data quality increased from around 5 in 1999 to a value of 9 in 2005. Seasonal PM data quality appears to be significantly affected by volatility of secondary aerosol species during warm months because ionic data quality regularly decreases in the summer. PM is more sensitive to total sulfate concentration than nitrate and ammonia year-round.","abstract_has_math":false,"creators":["Trail, Marcus"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Civil and Environmental Engineering","school":null,"contributors":[],"advisors":["Russell, Armistead G."],"committee_chairs":[],"committee_members":["Bergin, Mike","Mulholland, Jim"],"year":2010,"date_issued":"2010-04-08","date_published":"2010-04-08","updated_at":"2026-11-19T05:05:37Z","subjects":["Air pollution","PM₂. ₅","Environmental monitoring","Air quality","Air Pollution Measurement"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/33853","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/33853","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F33853","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Russell, Armistead G."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Bergin, Mike","Mulholland, Jim"]},{"key":"dc:contributor.department","label":"Department","values":["Civil and Environmental Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["School of Civil and Environmental Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Trail, Marcus"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2010-06-10T15:22:35Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2010-06-10T15:22:35Z"]},{"key":"dc:date.issued","label":"Date","values":["2010-04-08"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["23a79925-40ae-449e-840e-644668649d00"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Master of Science in Environmental Engineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["88639fad-d3ae-4867-9e7a-7c9e6d2ecc7c","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["f5b37bd1-c9d4-4451-bce6-05997d946169"]},{"key":"dc:type","label":"Dc Type","values":["Text","Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Air pollution","PM₂. ₅"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Air Pollution","Environmental monitoring","Air quality","Air Pollution Measurement"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/33853"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Beginning in March 1999 at Georgia Institute of Technology, the ASACA (Assessment of Spatial Aerosol Composition in Atlanta) program has provided PM₂. ₅ concentration and speciation using particle concentration monitoring in and around metropolitan Atlanta. Since 1999, three of the ASACA sites have collected PM₂. ₅ in an urban setting: Fort McPherson (FT, SW), South Dekalb (SD, SE), and Tucker (TU, NE). In January 2007, TU was retired and Fire Station 8 (FS8, NE) was employed as the new urban site. Starting in 2002, PM₂. ₅ concentrations have also been characterized at a rural site, Fort Yargo (YG). Water-soluble ionic species and carbonaceous species concentrations are collected daily on filters using a three-channel particulate composition monitor (PCM). From 1999 to 2008, average PM₂. ₅ concentrations range from 12.9 µg/m3 at YG to 15.4 µg/m3 at TU. Sulfate and organic matter are the main components of Atlanta PM, contributing around 26% and 31% respectively to PM mass. Overall ASACA data quality increased from around 5 in 1999 to a value of 9 in 2005. Seasonal PM data quality appears to be significantly affected by volatility of secondary aerosol species during warm months because ionic data quality regularly decreases in the summer. PM is more sensitive to total sulfate concentration than nitrate and ammonia year-round."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.S."]},{"key":"dc:title","label":"Title","values":["Atlanta PM₂. ₅, 1999-2008: asaca data trends, quality, and application to ion sensitivity analysis"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Russell, Armistead G."],"dc:contributor.committeemember":["Bergin, Mike","Mulholland, Jim"],"dc:contributor.department":["Civil and Environmental Engineering"],"dc:contributor.other":["School of Civil and Environmental Engineering","College of Engineering"],"dc:creator":["Trail, Marcus"],"dc:date.accessioned":["2010-06-10T15:22:35Z"],"dc:date.available":["2010-06-10T15:22:35Z"],"dc:date.issued":["2010-04-08"],"dc:description.abstract":["Beginning in March 1999 at Georgia Institute of Technology, the ASACA (Assessment of Spatial Aerosol Composition in Atlanta) program has provided PM₂. ₅ concentration and speciation using particle concentration monitoring in and around metropolitan Atlanta. Since 1999, three of the ASACA sites have collected PM₂. ₅ in an urban setting: Fort McPherson (FT, SW), South Dekalb (SD, SE), and Tucker (TU, NE). In January 2007, TU was retired and Fire Station 8 (FS8, NE) was employed as the new urban site. Starting in 2002, PM₂. ₅ concentrations have also been characterized at a rural site, Fort Yargo (YG). Water-soluble ionic species and carbonaceous species concentrations are collected daily on filters using a three-channel particulate composition monitor (PCM). From 1999 to 2008, average PM₂. ₅ concentrations range from 12.9 µg/m3 at YG to 15.4 µg/m3 at TU. Sulfate and organic matter are the main components of Atlanta PM, contributing around 26% and 31% respectively to PM mass. Overall ASACA data quality increased from around 5 in 1999 to a value of 9 in 2005. Seasonal PM data quality appears to be significantly affected by volatility of secondary aerosol species during warm months because ionic data quality regularly decreases in the summer. PM is more sensitive to total sulfate concentration than nitrate and ammonia year-round."],"dc:description.degree":["M.S."],"dc:identifier.uri":["http://hdl.handle.net/1853/33853"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["23a79925-40ae-449e-840e-644668649d00"],"dc:relation.ispartofseries":["Master of Science in Environmental Engineering"],"dc:relation.orgunit":["88639fad-d3ae-4867-9e7a-7c9e6d2ecc7c","7c022d60-21d5-497c-b552-95e489a06569"],"dc:relation.seriesentity":["f5b37bd1-c9d4-4451-bce6-05997d946169"],"dc:subject":["Air pollution","PM₂. ₅"],"dc:subject.lcsh":["Air Pollution","Environmental monitoring","Air quality","Air Pollution Measurement"],"dc:title":["Atlanta PM₂. ₅, 1999-2008: asaca data trends, quality, and application to ion sensitivity analysis"],"dc:type":["Text","Thesis"],"dspace:entity.type":["Publication"]},"updated_at":"2026-11-19T05:05:37Z"}