{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/37287"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/37287","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Advancements in high throughput protein profiling using surface enhanced laser desorption/ionization time of flight mass spectrometry","abstract":"Surface-enhanced laser desorption/ionization time-of-flight mass spectrometry (SELDI)is one of several proteomics technologies that can be used in biomarker discovery studies. Such studies often have the goal of finding protein markers that predict early onset of cancers such as cervical cancer. The reproducibility of SELDI has been shown to be an issue in the literature. There are numerous sources of error in a SELDI experiment starting with sample collection from patients to the signal processing steps used to estimate the protein mass and abundance values present in a sample. This dissertation is concerned with all aspects of signal processing related to SELDI's use in biomarker discovery projects. In chapter 2, we perform a comprehensive study of the most popular preprocessing algorithms available. Next, in chapter 3, we study the basic statistics of SELDI data acquisition. From here, we propose a quadratic variance measurement model for buffer+matrix only spectra. This model leads us to develop a modified Antoniadis-Sapatinas wavelet denoising algorithm that demonstrates superior performance when compared to MassSpecWavelet, one of the leading techniques for preprocessing SELDI data. In chapter 4, we show that the quadratic variance model 1) extends to real pooled cervical mucus QC data from a clinical study, 2) predicts behavior and reproducibility of peak heights, and 3) finds four times as many reproducible peaks as the vendor-supplied preprocessing programs. The quadratic variance measurement model for SELDI data is fundamental and promises to lead to improved techniques for analyzing the data from clinical studies using this instrument.","abstract_html":"Surface-enhanced laser desorption/ionization time-of-flight mass spectrometry (SELDI)is one of several proteomics technologies that can be used in biomarker discovery studies. Such studies often have the goal of finding protein markers that predict early onset of cancers such as cervical cancer. The reproducibility of SELDI has been shown to be an issue in the literature. There are numerous sources of error in a SELDI experiment starting with sample collection from patients to the signal processing steps used to estimate the protein mass and abundance values present in a sample. This dissertation is concerned with all aspects of signal processing related to SELDI&#x27;s use in biomarker discovery projects. In chapter 2, we perform a comprehensive study of the most popular preprocessing algorithms available. Next, in chapter 3, we study the basic statistics of SELDI data acquisition. From here, we propose a quadratic variance measurement model for buffer+matrix only spectra. This model leads us to develop a modified Antoniadis-Sapatinas wavelet denoising algorithm that demonstrates superior performance when compared to MassSpecWavelet, one of the leading techniques for preprocessing SELDI data. In chapter 4, we show that the quadratic variance model 1) extends to real pooled cervical mucus QC data from a clinical study, 2) predicts behavior and reproducibility of peak heights, and 3) finds four times as many reproducible peaks as the vendor-supplied preprocessing programs. The quadratic variance measurement model for SELDI data is fundamental and promises to lead to improved techniques for analyzing the data from clinical studies using this instrument.","abstract_has_math":false,"creators":["Emanuele, Vincent A., II"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Electrical and Computer Engineering","school":null,"contributors":[],"advisors":["Zhou, G. Tong"],"committee_chairs":[],"committee_members":["Fernandez, Facundo M.","Gurbaxani, Brian","Koblasz, Arthur","Ma, Xiaoli"],"year":2010,"date_issued":"2010-11-15","date_published":"2010-11-15","updated_at":"2026-11-19T05:08:08Z","subjects":["MALDI","SELDI","Peaks","Reproducibility","Matrix-assisted laser desorption-ionization","Mass spectrometry","Time-of-flight mass spectrometry"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/37287","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/37287","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F37287","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Zhou, G. Tong"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Fernandez, Facundo M.","Gurbaxani, Brian","Koblasz, Arthur","Ma, Xiaoli"]},{"key":"dc:contributor.department","label":"Department","values":["Electrical and Computer Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["School of Electrical and Computer Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Emanuele, Vincent A., II"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2011-03-04T21:04:53Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2011-03-04T21:04:53Z"]},{"key":"dc:date.issued","label":"Date","values":["2010-11-15"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["c02ccf1b-685f-47ca-a5ee-5996d39ede3d"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Doctor of Philosophy with a Major in Electrical and Computer Engineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["5b7adef2-447c-4270-b9fc-846bd76f80f2","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["3890cd56-8ecf-424b-8074-8f5ebd8dbe15"]},{"key":"dc:type","label":"Dc Type","values":["Text","Dissertation"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["MALDI","SELDI","Peaks","Reproducibility"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Matrix-assisted laser desorption-ionization","Mass spectrometry","Time-of-flight mass spectrometry"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/37287"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Surface-enhanced laser desorption/ionization time-of-flight mass spectrometry (SELDI)is one of several proteomics technologies that can be used in biomarker discovery studies. Such studies often have the goal of finding protein markers that predict early onset of cancers such as cervical cancer. The reproducibility of SELDI has been shown to be an issue in the literature. There are numerous sources of error in a SELDI experiment starting with sample collection from patients to the signal processing steps used to estimate the protein mass and abundance values present in a sample. This dissertation is concerned with all aspects of signal processing related to SELDI's use in biomarker discovery projects. In chapter 2, we perform a comprehensive study of the most popular preprocessing algorithms available. Next, in chapter 3, we study the basic statistics of SELDI data acquisition. From here, we propose a quadratic variance measurement model for buffer+matrix only spectra. This model leads us to develop a modified Antoniadis-Sapatinas wavelet denoising algorithm that demonstrates superior performance when compared to MassSpecWavelet, one of the leading techniques for preprocessing SELDI data. In chapter 4, we show that the quadratic variance model 1) extends to real pooled cervical mucus QC data from a clinical study, 2) predicts behavior and reproducibility of peak heights, and 3) finds four times as many reproducible peaks as the vendor-supplied preprocessing programs. The quadratic variance measurement model for SELDI data is fundamental and promises to lead to improved techniques for analyzing the data from clinical studies using this instrument."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph.D."]},{"key":"dc:title","label":"Title","values":["Advancements in high throughput protein profiling using surface enhanced laser desorption/ionization time of flight mass spectrometry"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Zhou, G. Tong"],"dc:contributor.committeemember":["Fernandez, Facundo M.","Gurbaxani, Brian","Koblasz, Arthur","Ma, Xiaoli"],"dc:contributor.department":["Electrical and Computer Engineering"],"dc:contributor.other":["School of Electrical and Computer Engineering","College of Engineering"],"dc:creator":["Emanuele, Vincent A., II"],"dc:date.accessioned":["2011-03-04T21:04:53Z"],"dc:date.available":["2011-03-04T21:04:53Z"],"dc:date.issued":["2010-11-15"],"dc:description.abstract":["Surface-enhanced laser desorption/ionization time-of-flight mass spectrometry (SELDI)is one of several proteomics technologies that can be used in biomarker discovery studies. Such studies often have the goal of finding protein markers that predict early onset of cancers such as cervical cancer. The reproducibility of SELDI has been shown to be an issue in the literature. There are numerous sources of error in a SELDI experiment starting with sample collection from patients to the signal processing steps used to estimate the protein mass and abundance values present in a sample. This dissertation is concerned with all aspects of signal processing related to SELDI's use in biomarker discovery projects. In chapter 2, we perform a comprehensive study of the most popular preprocessing algorithms available. Next, in chapter 3, we study the basic statistics of SELDI data acquisition. From here, we propose a quadratic variance measurement model for buffer+matrix only spectra. This model leads us to develop a modified Antoniadis-Sapatinas wavelet denoising algorithm that demonstrates superior performance when compared to MassSpecWavelet, one of the leading techniques for preprocessing SELDI data. In chapter 4, we show that the quadratic variance model 1) extends to real pooled cervical mucus QC data from a clinical study, 2) predicts behavior and reproducibility of peak heights, and 3) finds four times as many reproducible peaks as the vendor-supplied preprocessing programs. The quadratic variance measurement model for SELDI data is fundamental and promises to lead to improved techniques for analyzing the data from clinical studies using this instrument."],"dc:description.degree":["Ph.D."],"dc:identifier.uri":["http://hdl.handle.net/1853/37287"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["c02ccf1b-685f-47ca-a5ee-5996d39ede3d"],"dc:relation.ispartofseries":["Doctor of Philosophy with a Major in Electrical and Computer Engineering"],"dc:relation.orgunit":["5b7adef2-447c-4270-b9fc-846bd76f80f2","7c022d60-21d5-497c-b552-95e489a06569"],"dc:relation.seriesentity":["3890cd56-8ecf-424b-8074-8f5ebd8dbe15"],"dc:subject":["MALDI","SELDI","Peaks","Reproducibility"],"dc:subject.lcsh":["Matrix-assisted laser desorption-ionization","Mass spectrometry","Time-of-flight mass spectrometry"],"dc:title":["Advancements in high throughput protein profiling using surface enhanced laser desorption/ionization time of flight mass spectrometry"],"dc:type":["Text","Dissertation"],"dspace:entity.type":["Publication"]},"updated_at":"2026-11-19T05:08:08Z"}