{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/41073"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/41073","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Characterization of modified neutron fields with americium-beryllium and californium-252 sources","abstract":"There are a variety of uses for reference neutron fields including detector response and dosimeter studies. The Georgia Institute of Technology has a 252Cf spontaneous fission source and an AmBe (α, n) source available for use in its research programs. In addition, it has iron, lead, beryllium, tantalum, heavy water, and polyethylene spheres to modify the neutron energy distributions from these neutron sources. This research characterized the neutron leakage spectra from the source inside spherical shells using a Bonner sphere spectrometer. All the neutron fields measured were also computed with a Monte Carlo code to determine the neutron fluence rate and ambient dose equivalent rate. The comparison of experimental data and calculations are used to provide further insight into the neutron spectra as modified by the spheres. The characterization of these modified sources will provide data to assist in using the resulting neutron fields in other research activities. To measure each neutron field combination, one of the two sources was placed in the center of an attenuating sphere. The neutron field was first measured at a variety of source-to-detector distances with a Bonner Sphere System. The spectrometer measurements, specifically the count rates of the different Bonner spheres, as a function of distance from the source is fitted to obtain corrections for room-scatter and air-scatter of neutrons using the Eisenhauer, Schwartz, and Johnson method. Using these corrections, the count rates free of room return is obtained at 1 m from the source and unfolded using the BUMS software to obtain the reported fluence and dose equivalent rates. These results are compared to those generated by the Monte Carlo Neutral Particle (MCNP) code. Models were made in MCNP for each of the source and moderating sphere combinations. The neutron fluence and dose rates were tallied during the MCNP simulation. The unfolded experimental data and the MCNP calculations showed good agreement for most of source-attenuating sphere combinations, thereby reinforcing the experimental results.","abstract_html":"There are a variety of uses for reference neutron fields including detector response and dosimeter studies. The Georgia Institute of Technology has a 252Cf spontaneous fission source and an AmBe (α, n) source available for use in its research programs. In addition, it has iron, lead, beryllium, tantalum, heavy water, and polyethylene spheres to modify the neutron energy distributions from these neutron sources. This research characterized the neutron leakage spectra from the source inside spherical shells using a Bonner sphere spectrometer. All the neutron fields measured were also computed with a Monte Carlo code to determine the neutron fluence rate and ambient dose equivalent rate. The comparison of experimental data and calculations are used to provide further insight into the neutron spectra as modified by the spheres. The characterization of these modified sources will provide data to assist in using the resulting neutron fields in other research activities. To measure each neutron field combination, one of the two sources was placed in the center of an attenuating sphere. The neutron field was first measured at a variety of source-to-detector distances with a Bonner Sphere System. The spectrometer measurements, specifically the count rates of the different Bonner spheres, as a function of distance from the source is fitted to obtain corrections for room-scatter and air-scatter of neutrons using the Eisenhauer, Schwartz, and Johnson method. Using these corrections, the count rates free of room return is obtained at 1 m from the source and unfolded using the BUMS software to obtain the reported fluence and dose equivalent rates. These results are compared to those generated by the Monte Carlo Neutral Particle (MCNP) code. Models were made in MCNP for each of the source and moderating sphere combinations. The neutron fluence and dose rates were tallied during the MCNP simulation. The unfolded experimental data and the MCNP calculations showed good agreement for most of source-attenuating sphere combinations, thereby reinforcing the experimental results.","abstract_has_math":false,"creators":["Exline, Peter Riley"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["Hertel, Nolan E."],"committee_chairs":[],"committee_members":["Shannon, Michael","Wang, C-K Chris"],"year":2011,"date_issued":"2011-05-23","date_published":"2011-05-23","updated_at":"2026-11-19T03:53:32Z","subjects":["Neutron","Neutron fields","BSS","MCNP","Americium","Californium","Neutron detection","Characterization","Detection","Neutron irradiation","Radioactive substances Detection"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/41073","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/41073","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F41073","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Hertel, Nolan E."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Shannon, Michael","Wang, C-K Chris"]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["George W. Woodruff School of Mechanical Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Exline, Peter Riley"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2011-09-22T17:47:19Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2011-09-22T17:47:19Z"]},{"key":"dc:date.issued","label":"Date","values":["2011-05-23"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["26003284-0ae0-4887-a127-917eb8923925"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Master of Science in Nuclear Engineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["c01ff908-c25f-439b-bf10-a074ed886bb7","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["b2977479-131d-4733-a5d5-cadc72a6fad2"]},{"key":"dc:type","label":"Dc Type","values":["Text","Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Neutron","Neutron fields","BSS","MCNP","Americium","Californium","Neutron detection","Characterization","Detection"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Neutron irradiation","Radioactive substances Detection"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/41073"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["There are a variety of uses for reference neutron fields including detector response and dosimeter studies. The Georgia Institute of Technology has a 252Cf spontaneous fission source and an AmBe (α, n) source available for use in its research programs. In addition, it has iron, lead, beryllium, tantalum, heavy water, and polyethylene spheres to modify the neutron energy distributions from these neutron sources. This research characterized the neutron leakage spectra from the source inside spherical shells using a Bonner sphere spectrometer. All the neutron fields measured were also computed with a Monte Carlo code to determine the neutron fluence rate and ambient dose equivalent rate. The comparison of experimental data and calculations are used to provide further insight into the neutron spectra as modified by the spheres. The characterization of these modified sources will provide data to assist in using the resulting neutron fields in other research activities. To measure each neutron field combination, one of the two sources was placed in the center of an attenuating sphere. The neutron field was first measured at a variety of source-to-detector distances with a Bonner Sphere System. The spectrometer measurements, specifically the count rates of the different Bonner spheres, as a function of distance from the source is fitted to obtain corrections for room-scatter and air-scatter of neutrons using the Eisenhauer, Schwartz, and Johnson method. Using these corrections, the count rates free of room return is obtained at 1 m from the source and unfolded using the BUMS software to obtain the reported fluence and dose equivalent rates. These results are compared to those generated by the Monte Carlo Neutral Particle (MCNP) code. Models were made in MCNP for each of the source and moderating sphere combinations. The neutron fluence and dose rates were tallied during the MCNP simulation. The unfolded experimental data and the MCNP calculations showed good agreement for most of source-attenuating sphere combinations, thereby reinforcing the experimental results."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.S."]},{"key":"dc:title","label":"Title","values":["Characterization of modified neutron fields with americium-beryllium and californium-252 sources"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Hertel, Nolan E."],"dc:contributor.committeemember":["Shannon, Michael","Wang, C-K Chris"],"dc:contributor.department":["Mechanical Engineering"],"dc:contributor.other":["George W. Woodruff School of Mechanical Engineering","College of Engineering"],"dc:creator":["Exline, Peter Riley"],"dc:date.accessioned":["2011-09-22T17:47:19Z"],"dc:date.available":["2011-09-22T17:47:19Z"],"dc:date.issued":["2011-05-23"],"dc:description.abstract":["There are a variety of uses for reference neutron fields including detector response and dosimeter studies. The Georgia Institute of Technology has a 252Cf spontaneous fission source and an AmBe (α, n) source available for use in its research programs. In addition, it has iron, lead, beryllium, tantalum, heavy water, and polyethylene spheres to modify the neutron energy distributions from these neutron sources. This research characterized the neutron leakage spectra from the source inside spherical shells using a Bonner sphere spectrometer. All the neutron fields measured were also computed with a Monte Carlo code to determine the neutron fluence rate and ambient dose equivalent rate. The comparison of experimental data and calculations are used to provide further insight into the neutron spectra as modified by the spheres. The characterization of these modified sources will provide data to assist in using the resulting neutron fields in other research activities. To measure each neutron field combination, one of the two sources was placed in the center of an attenuating sphere. The neutron field was first measured at a variety of source-to-detector distances with a Bonner Sphere System. The spectrometer measurements, specifically the count rates of the different Bonner spheres, as a function of distance from the source is fitted to obtain corrections for room-scatter and air-scatter of neutrons using the Eisenhauer, Schwartz, and Johnson method. Using these corrections, the count rates free of room return is obtained at 1 m from the source and unfolded using the BUMS software to obtain the reported fluence and dose equivalent rates. These results are compared to those generated by the Monte Carlo Neutral Particle (MCNP) code. Models were made in MCNP for each of the source and moderating sphere combinations. The neutron fluence and dose rates were tallied during the MCNP simulation. The unfolded experimental data and the MCNP calculations showed good agreement for most of source-attenuating sphere combinations, thereby reinforcing the experimental results."],"dc:description.degree":["M.S."],"dc:identifier.uri":["http://hdl.handle.net/1853/41073"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["26003284-0ae0-4887-a127-917eb8923925"],"dc:relation.ispartofseries":["Master of Science in Nuclear Engineering"],"dc:relation.orgunit":["c01ff908-c25f-439b-bf10-a074ed886bb7","7c022d60-21d5-497c-b552-95e489a06569"],"dc:relation.seriesentity":["b2977479-131d-4733-a5d5-cadc72a6fad2"],"dc:subject":["Neutron","Neutron fields","BSS","MCNP","Americium","Californium","Neutron detection","Characterization","Detection"],"dc:subject.lcsh":["Neutron irradiation","Radioactive substances Detection"],"dc:title":["Characterization of modified neutron fields with americium-beryllium and californium-252 sources"],"dc:type":["Text","Thesis"],"dspace:entity.type":["Publication"]},"updated_at":"2026-11-19T03:53:32Z"}