{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/41080"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/41080","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Development of a polyvinyl alcohol cryogel covered stent","abstract":"Atherosclerosis is the number one cause of death in the United States and one of the most common treatments is the implantation of a stent. In order to eliminate the two most common complications - restenosis and thrombosis - a novel covered stent is investigated. A covered stent membrane should be able to undergo large stretch, prevent restenosis, and be relatively non-thrombogenic. Polyvinyl alcohol (PVA) cryogels are examined as a candidate material for covered stent membranes. Mechanical testing included uniaxial tensile testing, puncture testing, and the fabrication and expansion of PVA cryogel covered stents. Uniaxial testing showed PVA cryogels to have sufficient ultimate stretch which was similar to bare metal stents during deployment. Puncture testing revealed that PVA cryogels are not likely to puncture in vivo. No tears were seen in the PVA cryogel membrane after expansion of the covered stents. Finite element analysis was used to determine a PVA cryogel membrane's effect on artery wall stress. PVA cryogel covered stents reduced both artery wall stress and tissue prolapse when compared to equivalent uncovered stents. Migration assays were used to determine if PVA cryogels are able to block the smooth muscle cell migration seen during restenosis. PVA cryogels significantly reduced cellular migration in modified Boyden chambers - suggesting that they would be able to prevent restenosis in vivo. Thrombogenicity was tested in vitro with a gravity-fed flow loop using porcine blood and in vivo with a sheep model. PVA cryogels were found to be less thrombogenic than polyester controls with the flow loop system. The sheep study demonstrated the feasibility of implanting PVA cryogel covered stents and good early patency. After explantation, the PVA cryogel membranes were intact - providing in vivo evidence for the durability of PVA cryogel covered stents. Overall, this work provides evidence that covered stents made with PVA cryogels are a feasible device in terms of their mechanics, ability to prevent restenosis, and low thrombogenicity. This work represents a major advancement in the development of PVA cryogel covered stents and provides necessary safety and feasibility data for future clinical trials.","abstract_html":"Atherosclerosis is the number one cause of death in the United States and one of the most common treatments is the implantation of a stent. In order to eliminate the two most common complications - restenosis and thrombosis - a novel covered stent is investigated. A covered stent membrane should be able to undergo large stretch, prevent restenosis, and be relatively non-thrombogenic. Polyvinyl alcohol (PVA) cryogels are examined as a candidate material for covered stent membranes. Mechanical testing included uniaxial tensile testing, puncture testing, and the fabrication and expansion of PVA cryogel covered stents. Uniaxial testing showed PVA cryogels to have sufficient ultimate stretch which was similar to bare metal stents during deployment. Puncture testing revealed that PVA cryogels are not likely to puncture in vivo. No tears were seen in the PVA cryogel membrane after expansion of the covered stents. Finite element analysis was used to determine a PVA cryogel membrane&#x27;s effect on artery wall stress. PVA cryogel covered stents reduced both artery wall stress and tissue prolapse when compared to equivalent uncovered stents. Migration assays were used to determine if PVA cryogels are able to block the smooth muscle cell migration seen during restenosis. PVA cryogels significantly reduced cellular migration in modified Boyden chambers - suggesting that they would be able to prevent restenosis in vivo. Thrombogenicity was tested in vitro with a gravity-fed flow loop using porcine blood and in vivo with a sheep model. PVA cryogels were found to be less thrombogenic than polyester controls with the flow loop system. The sheep study demonstrated the feasibility of implanting PVA cryogel covered stents and good early patency. After explantation, the PVA cryogel membranes were intact - providing in vivo evidence for the durability of PVA cryogel covered stents. Overall, this work provides evidence that covered stents made with PVA cryogels are a feasible device in terms of their mechanics, ability to prevent restenosis, and low thrombogenicity. This work represents a major advancement in the development of PVA cryogel covered stents and provides necessary safety and feasibility data for future clinical trials.","abstract_has_math":false,"creators":["Weaver, Jason David"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Biomedical Engineering","school":null,"contributors":[],"advisors":["Taylor, W. Robert","Ku, David N."],"committee_chairs":[],"committee_members":["Chaikof, Elliot L.","Finn, Aloke V.","Gleason, Rudolph L.","McIntire, Larry V."],"year":2010,"date_issued":"2010-05-12","date_published":"2010-05-12","updated_at":"2026-11-19T04:03:22Z","subjects":["Covered stent","Polyvinyl alcohol cryogel","Restenosis","Thrombosis","Mechanics","Atherosclerosis","Biomedical materials","Biomedical materials Research"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/41080","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/41080","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F41080","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Taylor, W. Robert","Ku, David N."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Chaikof, Elliot L.","Finn, Aloke V.","Gleason, Rudolph L.","McIntire, Larry V."]},{"key":"dc:contributor.department","label":"Department","values":["Biomedical Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Wallace H. Coulter Department of Biomedical Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Weaver, Jason David"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2011-09-22T17:47:21Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2011-09-22T17:47:21Z"]},{"key":"dc:date.issued","label":"Date","values":["2010-05-12"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["61ce23da-1f00-4546-85ff-bf6b236680eb","fcccb519-e993-4e74-80be-d919b82c6af4"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Doctor of Philosophy with a Major in Biomedical Engineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["da59be3c-3d0a-41da-91b9-ebe2ecc83b66","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["d85f9f1b-b2b5-4bca-81af-4515c5281e54"]},{"key":"dc:type","label":"Dc Type","values":["Text","Dissertation"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Covered stent","Polyvinyl alcohol cryogel","Restenosis","Thrombosis","Mechanics"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Atherosclerosis","Biomedical materials","Biomedical materials Research"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/41080"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Atherosclerosis is the number one cause of death in the United States and one of the most common treatments is the implantation of a stent. In order to eliminate the two most common complications - restenosis and thrombosis - a novel covered stent is investigated. A covered stent membrane should be able to undergo large stretch, prevent restenosis, and be relatively non-thrombogenic. Polyvinyl alcohol (PVA) cryogels are examined as a candidate material for covered stent membranes. Mechanical testing included uniaxial tensile testing, puncture testing, and the fabrication and expansion of PVA cryogel covered stents. Uniaxial testing showed PVA cryogels to have sufficient ultimate stretch which was similar to bare metal stents during deployment. Puncture testing revealed that PVA cryogels are not likely to puncture in vivo. No tears were seen in the PVA cryogel membrane after expansion of the covered stents. Finite element analysis was used to determine a PVA cryogel membrane's effect on artery wall stress. PVA cryogel covered stents reduced both artery wall stress and tissue prolapse when compared to equivalent uncovered stents. Migration assays were used to determine if PVA cryogels are able to block the smooth muscle cell migration seen during restenosis. PVA cryogels significantly reduced cellular migration in modified Boyden chambers - suggesting that they would be able to prevent restenosis in vivo. Thrombogenicity was tested in vitro with a gravity-fed flow loop using porcine blood and in vivo with a sheep model. PVA cryogels were found to be less thrombogenic than polyester controls with the flow loop system. The sheep study demonstrated the feasibility of implanting PVA cryogel covered stents and good early patency. After explantation, the PVA cryogel membranes were intact - providing in vivo evidence for the durability of PVA cryogel covered stents. Overall, this work provides evidence that covered stents made with PVA cryogels are a feasible device in terms of their mechanics, ability to prevent restenosis, and low thrombogenicity. This work represents a major advancement in the development of PVA cryogel covered stents and provides necessary safety and feasibility data for future clinical trials."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph.D."]},{"key":"dc:title","label":"Title","values":["Development of a polyvinyl alcohol cryogel covered stent"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Taylor, W. Robert","Ku, David N."],"dc:contributor.committeemember":["Chaikof, Elliot L.","Finn, Aloke V.","Gleason, Rudolph L.","McIntire, Larry V."],"dc:contributor.department":["Biomedical Engineering"],"dc:contributor.other":["Wallace H. Coulter Department of Biomedical Engineering","College of Engineering"],"dc:creator":["Weaver, Jason David"],"dc:date.accessioned":["2011-09-22T17:47:21Z"],"dc:date.available":["2011-09-22T17:47:21Z"],"dc:date.issued":["2010-05-12"],"dc:description.abstract":["Atherosclerosis is the number one cause of death in the United States and one of the most common treatments is the implantation of a stent. In order to eliminate the two most common complications - restenosis and thrombosis - a novel covered stent is investigated. A covered stent membrane should be able to undergo large stretch, prevent restenosis, and be relatively non-thrombogenic. Polyvinyl alcohol (PVA) cryogels are examined as a candidate material for covered stent membranes. Mechanical testing included uniaxial tensile testing, puncture testing, and the fabrication and expansion of PVA cryogel covered stents. Uniaxial testing showed PVA cryogels to have sufficient ultimate stretch which was similar to bare metal stents during deployment. Puncture testing revealed that PVA cryogels are not likely to puncture in vivo. No tears were seen in the PVA cryogel membrane after expansion of the covered stents. Finite element analysis was used to determine a PVA cryogel membrane's effect on artery wall stress. PVA cryogel covered stents reduced both artery wall stress and tissue prolapse when compared to equivalent uncovered stents. Migration assays were used to determine if PVA cryogels are able to block the smooth muscle cell migration seen during restenosis. PVA cryogels significantly reduced cellular migration in modified Boyden chambers - suggesting that they would be able to prevent restenosis in vivo. Thrombogenicity was tested in vitro with a gravity-fed flow loop using porcine blood and in vivo with a sheep model. PVA cryogels were found to be less thrombogenic than polyester controls with the flow loop system. The sheep study demonstrated the feasibility of implanting PVA cryogel covered stents and good early patency. After explantation, the PVA cryogel membranes were intact - providing in vivo evidence for the durability of PVA cryogel covered stents. Overall, this work provides evidence that covered stents made with PVA cryogels are a feasible device in terms of their mechanics, ability to prevent restenosis, and low thrombogenicity. This work represents a major advancement in the development of PVA cryogel covered stents and provides necessary safety and feasibility data for future clinical trials."],"dc:description.degree":["Ph.D."],"dc:identifier.uri":["http://hdl.handle.net/1853/41080"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["61ce23da-1f00-4546-85ff-bf6b236680eb","fcccb519-e993-4e74-80be-d919b82c6af4"],"dc:relation.ispartofseries":["Doctor of Philosophy with a Major in Biomedical Engineering"],"dc:relation.orgunit":["da59be3c-3d0a-41da-91b9-ebe2ecc83b66","7c022d60-21d5-497c-b552-95e489a06569"],"dc:relation.seriesentity":["d85f9f1b-b2b5-4bca-81af-4515c5281e54"],"dc:subject":["Covered stent","Polyvinyl alcohol cryogel","Restenosis","Thrombosis","Mechanics"],"dc:subject.lcsh":["Atherosclerosis","Biomedical materials","Biomedical materials Research"],"dc:title":["Development of a polyvinyl alcohol cryogel covered stent"],"dc:type":["Text","Dissertation"],"dspace:entity.type":["Publication"]},"updated_at":"2026-11-19T04:03:22Z"}