{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/43745"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/43745","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Liquid-Salt-Cooled Reactor start-up with natural circulation under Loss-of-Offsite-Power (LOOP) conditions","abstract":"The Liquid-Salt-Cooled Very High-Temperature Reactor (LS-VHTR) was modeled using the neutronics analysis code SCALE6.0 and the thermal-hydraulics and kinetics modeling code RELAP5-3D with objective to devise, analyze, and evaluate the feasibility and stability of a start-up procedure for this reactor using natural circulation of the coolant and under the Loss Of Offsite Power (LOOP) conditions. This Generation IV reactor design has been studied by research facilities worldwide for almost a decade. While neutronics and thermal-hydraulics analyses have been previously performed to show the performance of the reactor during normal operation and for shutdown scenarios, no study has heretofore been published to examine the active or passive start-up of the reactor. The fuel temperature (Doppler) and coolant density coefficient of reactivity of the LS-VHTR were examined using the CSAS6 module of the SCALE6.0 code. Negative Doppler and coolant density feedback coefficients were calculated. Two initial RELAP5 simulations were run to obtain the steady-state conditions of the model and to predict the changes of the thermal-hydraulic parameters during the shutdown of the reactor. Next, a series of step reactivity additions to the core were simulated to determine how much reactivity can be inserted without jeopardizing safety and the stability of the core. Finally, a start-up procedure was developed, and the restart of the reactor with natural convection of the coolant was simulated. The results of the simulations demonstrated the potential of a passive start-up of the LS-VHTR.","abstract_html":"The Liquid-Salt-Cooled Very High-Temperature Reactor (LS-VHTR) was modeled using the neutronics analysis code SCALE6.0 and the thermal-hydraulics and kinetics modeling code RELAP5-3D with objective to devise, analyze, and evaluate the feasibility and stability of a start-up procedure for this reactor using natural circulation of the coolant and under the Loss Of Offsite Power (LOOP) conditions. This Generation IV reactor design has been studied by research facilities worldwide for almost a decade. While neutronics and thermal-hydraulics analyses have been previously performed to show the performance of the reactor during normal operation and for shutdown scenarios, no study has heretofore been published to examine the active or passive start-up of the reactor. The fuel temperature (Doppler) and coolant density coefficient of reactivity of the LS-VHTR were examined using the CSAS6 module of the SCALE6.0 code. Negative Doppler and coolant density feedback coefficients were calculated. Two initial RELAP5 simulations were run to obtain the steady-state conditions of the model and to predict the changes of the thermal-hydraulic parameters during the shutdown of the reactor. Next, a series of step reactivity additions to the core were simulated to determine how much reactivity can be inserted without jeopardizing safety and the stability of the core. Finally, a start-up procedure was developed, and the restart of the reactor with natural convection of the coolant was simulated. The results of the simulations demonstrated the potential of a passive start-up of the LS-VHTR.","abstract_has_math":false,"creators":["Gros, Emilien B."],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Nuclear and Radiological Engineering","school":null,"contributors":[],"advisors":["Petrovic, Bojan"],"committee_chairs":[],"committee_members":["Davor Grgic","Graydon Yoder","Scott Duncan","Garimella, Srinivas"],"year":2012,"date_issued":"2012-01-18","date_published":"2012-01-18","updated_at":"2026-11-19T05:08:37Z","subjects":["Liquid-salt","Reactor","Start-up","Loss of offsite power","Molten salt reactors","Nuclear power plants Power supply","Electric power failures"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/43745","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/43745","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F43745","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Petrovic, Bojan"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Davor Grgic","Graydon Yoder","Scott Duncan","Garimella, Srinivas"]},{"key":"dc:contributor.department","label":"Department","values":["Nuclear and Radiological Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["George W. Woodruff School of Mechanical Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Gros, Emilien B."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-06-06T16:50:59Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-06-06T16:50:59Z"]},{"key":"dc:date.issued","label":"Date","values":["2012-01-18"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["0f37df6e-3498-4ce4-96d4-6df34e533f87"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Master of Science in Nuclear Engineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["c01ff908-c25f-439b-bf10-a074ed886bb7","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["b2977479-131d-4733-a5d5-cadc72a6fad2"]},{"key":"dc:type","label":"Dc Type","values":["Text","Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Liquid-salt","Reactor","Start-up","Loss of offsite power"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Molten salt reactors","Nuclear power plants Power supply","Electric power failures"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/43745"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The Liquid-Salt-Cooled Very High-Temperature Reactor (LS-VHTR) was modeled using the neutronics analysis code SCALE6.0 and the thermal-hydraulics and kinetics modeling code RELAP5-3D with objective to devise, analyze, and evaluate the feasibility and stability of a start-up procedure for this reactor using natural circulation of the coolant and under the Loss Of Offsite Power (LOOP) conditions. This Generation IV reactor design has been studied by research facilities worldwide for almost a decade. While neutronics and thermal-hydraulics analyses have been previously performed to show the performance of the reactor during normal operation and for shutdown scenarios, no study has heretofore been published to examine the active or passive start-up of the reactor. The fuel temperature (Doppler) and coolant density coefficient of reactivity of the LS-VHTR were examined using the CSAS6 module of the SCALE6.0 code. Negative Doppler and coolant density feedback coefficients were calculated. Two initial RELAP5 simulations were run to obtain the steady-state conditions of the model and to predict the changes of the thermal-hydraulic parameters during the shutdown of the reactor. Next, a series of step reactivity additions to the core were simulated to determine how much reactivity can be inserted without jeopardizing safety and the stability of the core. Finally, a start-up procedure was developed, and the restart of the reactor with natural convection of the coolant was simulated. The results of the simulations demonstrated the potential of a passive start-up of the LS-VHTR."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["MS"]},{"key":"dc:title","label":"Title","values":["Liquid-Salt-Cooled Reactor start-up with natural circulation under Loss-of-Offsite-Power (LOOP) conditions"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Petrovic, Bojan"],"dc:contributor.committeemember":["Davor Grgic","Graydon Yoder","Scott Duncan","Garimella, Srinivas"],"dc:contributor.department":["Nuclear and Radiological Engineering"],"dc:contributor.other":["George W. Woodruff School of Mechanical Engineering","College of Engineering"],"dc:creator":["Gros, Emilien B."],"dc:date.accessioned":["2012-06-06T16:50:59Z"],"dc:date.available":["2012-06-06T16:50:59Z"],"dc:date.issued":["2012-01-18"],"dc:description.abstract":["The Liquid-Salt-Cooled Very High-Temperature Reactor (LS-VHTR) was modeled using the neutronics analysis code SCALE6.0 and the thermal-hydraulics and kinetics modeling code RELAP5-3D with objective to devise, analyze, and evaluate the feasibility and stability of a start-up procedure for this reactor using natural circulation of the coolant and under the Loss Of Offsite Power (LOOP) conditions. This Generation IV reactor design has been studied by research facilities worldwide for almost a decade. While neutronics and thermal-hydraulics analyses have been previously performed to show the performance of the reactor during normal operation and for shutdown scenarios, no study has heretofore been published to examine the active or passive start-up of the reactor. The fuel temperature (Doppler) and coolant density coefficient of reactivity of the LS-VHTR were examined using the CSAS6 module of the SCALE6.0 code. Negative Doppler and coolant density feedback coefficients were calculated. Two initial RELAP5 simulations were run to obtain the steady-state conditions of the model and to predict the changes of the thermal-hydraulic parameters during the shutdown of the reactor. Next, a series of step reactivity additions to the core were simulated to determine how much reactivity can be inserted without jeopardizing safety and the stability of the core. Finally, a start-up procedure was developed, and the restart of the reactor with natural convection of the coolant was simulated. The results of the simulations demonstrated the potential of a passive start-up of the LS-VHTR."],"dc:description.degree":["MS"],"dc:identifier.uri":["http://hdl.handle.net/1853/43745"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["0f37df6e-3498-4ce4-96d4-6df34e533f87"],"dc:relation.ispartofseries":["Master of Science in Nuclear Engineering"],"dc:relation.orgunit":["c01ff908-c25f-439b-bf10-a074ed886bb7","7c022d60-21d5-497c-b552-95e489a06569"],"dc:relation.seriesentity":["b2977479-131d-4733-a5d5-cadc72a6fad2"],"dc:subject":["Liquid-salt","Reactor","Start-up","Loss of offsite power"],"dc:subject.lcsh":["Molten salt reactors","Nuclear power plants Power supply","Electric power failures"],"dc:title":["Liquid-Salt-Cooled Reactor start-up with natural circulation under Loss-of-Offsite-Power (LOOP) conditions"],"dc:type":["Text","Thesis"],"dspace:entity.type":["Publication"]},"updated_at":"2026-11-19T05:08:37Z"}