{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/44816"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/44816","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Pulse height tally response expansion method for application in detector problems","abstract":"A pulse height tally response expansion (PHRE) method is developed for detectors. By expanding the incident flux at the detector window/surface, a set of response functions is constructed via Monte Carlo estimators for pulse height tallies. B-spline functions are selected to perform the expansion of the response functions as well as for the expansion of the incident flux in photon energy. The method is verified for several incident flux spectra on a CsI(Na) detector. Results are compared to the solutions generated using direct Monte Carlo calculations. It is found that the method is several orders faster than MCNP5 while maintaining paralleled accuracy.","abstract_html":"A pulse height tally response expansion (PHRE) method is developed for detectors. By expanding the incident flux at the detector window/surface, a set of response functions is constructed via Monte Carlo estimators for pulse height tallies. B-spline functions are selected to perform the expansion of the response functions as well as for the expansion of the incident flux in photon energy. The method is verified for several incident flux spectra on a CsI(Na) detector. Results are compared to the solutions generated using direct Monte Carlo calculations. It is found that the method is several orders faster than MCNP5 while maintaining paralleled accuracy.","abstract_has_math":false,"creators":["Zipperer, Travis Jonathan"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Nuclear and Radiological Engineering","school":null,"contributors":[],"advisors":["Rahnema, Farzad"],"committee_chairs":[],"committee_members":["Sjoden, Glenn","Zhang, Dingkang"],"year":2011,"date_issued":"2011-07-07","date_published":"2011-07-07","updated_at":"2026-11-19T05:59:11Z","subjects":["Response functions","Radiation detectors","Monte Carlo method","Pulse height analyzers","Nuclear physics"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/44816","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/44816","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F44816","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Rahnema, Farzad"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Sjoden, Glenn","Zhang, Dingkang"]},{"key":"dc:contributor.department","label":"Department","values":["Nuclear and Radiological Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["George W. Woodruff School of Mechanical Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Zipperer, Travis Jonathan"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-09-20T18:20:30Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-09-20T18:20:30Z"]},{"key":"dc:date.issued","label":"Date","values":["2011-07-07"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["1d96b222-d2f0-46d1-a0c7-4d1f9254dfab"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Master of Science in Nuclear Engineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["c01ff908-c25f-439b-bf10-a074ed886bb7","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["b2977479-131d-4733-a5d5-cadc72a6fad2"]},{"key":"dc:type","label":"Dc Type","values":["Text","Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Response functions","Radiation detectors","Monte Carlo method"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Pulse height analyzers","Nuclear physics","Monte Carlo method"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/44816"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A pulse height tally response expansion (PHRE) method is developed for detectors. By expanding the incident flux at the detector window/surface, a set of response functions is constructed via Monte Carlo estimators for pulse height tallies. B-spline functions are selected to perform the expansion of the response functions as well as for the expansion of the incident flux in photon energy. The method is verified for several incident flux spectra on a CsI(Na) detector. Results are compared to the solutions generated using direct Monte Carlo calculations. It is found that the method is several orders faster than MCNP5 while maintaining paralleled accuracy."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["MS"]},{"key":"dc:title","label":"Title","values":["Pulse height tally response expansion method for application in detector problems"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Rahnema, Farzad"],"dc:contributor.committeemember":["Sjoden, Glenn","Zhang, Dingkang"],"dc:contributor.department":["Nuclear and Radiological Engineering"],"dc:contributor.other":["George W. Woodruff School of Mechanical Engineering","College of Engineering"],"dc:creator":["Zipperer, Travis Jonathan"],"dc:date.accessioned":["2012-09-20T18:20:30Z"],"dc:date.available":["2012-09-20T18:20:30Z"],"dc:date.issued":["2011-07-07"],"dc:description.abstract":["A pulse height tally response expansion (PHRE) method is developed for detectors. By expanding the incident flux at the detector window/surface, a set of response functions is constructed via Monte Carlo estimators for pulse height tallies. B-spline functions are selected to perform the expansion of the response functions as well as for the expansion of the incident flux in photon energy. The method is verified for several incident flux spectra on a CsI(Na) detector. Results are compared to the solutions generated using direct Monte Carlo calculations. It is found that the method is several orders faster than MCNP5 while maintaining paralleled accuracy."],"dc:description.degree":["MS"],"dc:identifier.uri":["http://hdl.handle.net/1853/44816"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["1d96b222-d2f0-46d1-a0c7-4d1f9254dfab"],"dc:relation.ispartofseries":["Master of Science in Nuclear Engineering"],"dc:relation.orgunit":["c01ff908-c25f-439b-bf10-a074ed886bb7","7c022d60-21d5-497c-b552-95e489a06569"],"dc:relation.seriesentity":["b2977479-131d-4733-a5d5-cadc72a6fad2"],"dc:subject":["Response functions","Radiation detectors","Monte Carlo method"],"dc:subject.lcsh":["Pulse height analyzers","Nuclear physics","Monte Carlo method"],"dc:title":["Pulse height tally response expansion method for application in detector problems"],"dc:type":["Text","Thesis"],"dspace:entity.type":["Publication"]},"updated_at":"2026-11-19T05:59:11Z"}