{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/44829"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/44829","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"A force and displacement self-sensing method for a mri compatible tweezer end effector","abstract":"This work describes a self-sensing technique for a piezoelectrically driven MRI-compatible tweezer style end effector, suitable for robot assisted, MRI guided surgery. Nested strain amplification mechanisms are used to amplify the displacement of the piezo actuators to practical levels for robotics. By using a hysteretic piezoelectric model and a two port network model for the compliant nested strain amplifiers, it is shown that force and displacement at the tweezer tip can be estimated if the input voltage and charge are measured. One piezo unit is used simultaneously as a sensor and an actuator, preserving the full actuation capability of the device. Experimental validation shows an average of 12% error between the self-sensed and true values.","abstract_html":"This work describes a self-sensing technique for a piezoelectrically driven MRI-compatible tweezer style end effector, suitable for robot assisted, MRI guided surgery. Nested strain amplification mechanisms are used to amplify the displacement of the piezo actuators to practical levels for robotics. By using a hysteretic piezoelectric model and a two port network model for the compliant nested strain amplifiers, it is shown that force and displacement at the tweezer tip can be estimated if the input voltage and charge are measured. One piezo unit is used simultaneously as a sensor and an actuator, preserving the full actuation capability of the device. Experimental validation shows an average of 12% error between the self-sensed and true values.","abstract_has_math":false,"creators":["McPherson, Timothy Steven"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["Ueda, Jun"],"committee_chairs":[],"committee_members":["Erturk, Alper","Ferri, Aldo"],"year":2012,"date_issued":"2012-07-05","date_published":"2012-07-05","updated_at":"2026-11-19T06:09:43Z","subjects":["Piezoelectric actuation","Self sensing","Robotics","MRI compatible","Surgical instruments and apparatus","Robotics in medicine","Computer-assisted surgery","Piezoelectricity","Surgical robots","Magnetic resonance imaging"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/44829","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/44829","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F44829","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Ueda, Jun"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Erturk, Alper","Ferri, Aldo"]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["George W. Woodruff School of Mechanical Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["McPherson, Timothy Steven"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-09-20T18:20:33Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-09-20T18:20:33Z"]},{"key":"dc:date.issued","label":"Date","values":["2012-07-05"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["7ff601c5-b262-4830-8a06-b75c55f5f1c8"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["c01ff908-c25f-439b-bf10-a074ed886bb7","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:type","label":"Dc Type","values":["Text","Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Piezoelectric actuation","Self sensing","Robotics","MRI compatible"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Surgical instruments and apparatus","Robotics in medicine","Computer-assisted surgery","Piezoelectricity","Surgical robots","Magnetic resonance imaging"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/44829"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This work describes a self-sensing technique for a piezoelectrically driven MRI-compatible tweezer style end effector, suitable for robot assisted, MRI guided surgery. Nested strain amplification mechanisms are used to amplify the displacement of the piezo actuators to practical levels for robotics. By using a hysteretic piezoelectric model and a two port network model for the compliant nested strain amplifiers, it is shown that force and displacement at the tweezer tip can be estimated if the input voltage and charge are measured. One piezo unit is used simultaneously as a sensor and an actuator, preserving the full actuation capability of the device. Experimental validation shows an average of 12% error between the self-sensed and true values."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["MS"]},{"key":"dc:title","label":"Title","values":["A force and displacement self-sensing method for a mri compatible tweezer end effector"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Ueda, Jun"],"dc:contributor.committeemember":["Erturk, Alper","Ferri, Aldo"],"dc:contributor.department":["Mechanical Engineering"],"dc:contributor.other":["George W. Woodruff School of Mechanical Engineering","College of Engineering"],"dc:creator":["McPherson, Timothy Steven"],"dc:date.accessioned":["2012-09-20T18:20:33Z"],"dc:date.available":["2012-09-20T18:20:33Z"],"dc:date.issued":["2012-07-05"],"dc:description.abstract":["This work describes a self-sensing technique for a piezoelectrically driven MRI-compatible tweezer style end effector, suitable for robot assisted, MRI guided surgery. Nested strain amplification mechanisms are used to amplify the displacement of the piezo actuators to practical levels for robotics. By using a hysteretic piezoelectric model and a two port network model for the compliant nested strain amplifiers, it is shown that force and displacement at the tweezer tip can be estimated if the input voltage and charge are measured. One piezo unit is used simultaneously as a sensor and an actuator, preserving the full actuation capability of the device. Experimental validation shows an average of 12% error between the self-sensed and true values."],"dc:description.degree":["MS"],"dc:identifier.uri":["http://hdl.handle.net/1853/44829"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["7ff601c5-b262-4830-8a06-b75c55f5f1c8"],"dc:relation.orgunit":["c01ff908-c25f-439b-bf10-a074ed886bb7","7c022d60-21d5-497c-b552-95e489a06569"],"dc:subject":["Piezoelectric actuation","Self sensing","Robotics","MRI compatible"],"dc:subject.lcsh":["Surgical instruments and apparatus","Robotics in medicine","Computer-assisted surgery","Piezoelectricity","Surgical robots","Magnetic resonance imaging"],"dc:title":["A force and displacement self-sensing method for a mri compatible tweezer end effector"],"dc:type":["Text","Thesis"],"dspace:entity.type":["Publication"]},"updated_at":"2026-11-19T06:09:43Z"}