{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/44857"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/44857","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Laser-induced fluorescence measurements of dual plumes and comparison of laser-induced fluorescence and conductivity probe measurements","abstract":"The laser-induced fluorescence (LIF) technique is used to visualize and quantify the concentration field around a conductivity probe. The LIF data are compared to the signal collected by the conductivity probe. The objective is to compare the signal of the contact-sensor to the \"ground-truth\" measurement of the LIF data. Detailed comparison of the temporal response and the peak detection are presented. In addition, a proof-of-concept of a two-color LIF technique is presented using Rhodamine 6G paired with an Argon-ion laser and simultaneously Oxazine 725 paired with a Krypton-ion laser. Optical filters on two digital cameras isolate the emitted light from these respective laser/dye combinations. The objective is to provide detailed quantitation of two over-lapping (non-reactive)chemical plumes.","abstract_html":"The laser-induced fluorescence (LIF) technique is used to visualize and quantify the concentration field around a conductivity probe. The LIF data are compared to the signal collected by the conductivity probe. The objective is to compare the signal of the contact-sensor to the &quot;ground-truth&quot; measurement of the LIF data. Detailed comparison of the temporal response and the peak detection are presented. In addition, a proof-of-concept of a two-color LIF technique is presented using Rhodamine 6G paired with an Argon-ion laser and simultaneously Oxazine 725 paired with a Krypton-ion laser. Optical filters on two digital cameras isolate the emitted light from these respective laser/dye combinations. The objective is to provide detailed quantitation of two over-lapping (non-reactive)chemical plumes.","abstract_has_math":false,"creators":["Chrzan, Joseph Coleman"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Civil and Environmental Engineering","school":null,"contributors":[],"advisors":["Webster, Donald R."],"committee_chairs":[],"committee_members":["Roberts, Philip","Weissburg, Marc"],"year":2012,"date_issued":"2012-07-10","date_published":"2012-07-10","updated_at":"2026-11-19T06:00:38Z","subjects":["Conductivity probe","Fluorescence","Lif","Plif","Plumes (Fluid dynamics)"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/44857","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/44857","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F44857","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Webster, Donald R."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Roberts, Philip","Weissburg, Marc"]},{"key":"dc:contributor.department","label":"Department","values":["Civil and Environmental Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["School of Civil and Environmental Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Chrzan, Joseph Coleman"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-09-20T18:22:18Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-09-20T18:22:18Z"]},{"key":"dc:date.issued","label":"Date","values":["2012-07-10"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["d69f5efb-5a6a-4324-b538-55bc6b7ba279"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["88639fad-d3ae-4867-9e7a-7c9e6d2ecc7c","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:type","label":"Dc Type","values":["Text","Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Conductivity probe","Fluorescence","Lif","Plif"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Plumes (Fluid dynamics)"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/44857"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The laser-induced fluorescence (LIF) technique is used to visualize and quantify the concentration field around a conductivity probe. The LIF data are compared to the signal collected by the conductivity probe. The objective is to compare the signal of the contact-sensor to the \"ground-truth\" measurement of the LIF data. Detailed comparison of the temporal response and the peak detection are presented. In addition, a proof-of-concept of a two-color LIF technique is presented using Rhodamine 6G paired with an Argon-ion laser and simultaneously Oxazine 725 paired with a Krypton-ion laser. Optical filters on two digital cameras isolate the emitted light from these respective laser/dye combinations. The objective is to provide detailed quantitation of two over-lapping (non-reactive)chemical plumes."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["MS"]},{"key":"dc:title","label":"Title","values":["Laser-induced fluorescence measurements of dual plumes and comparison of laser-induced fluorescence and conductivity probe measurements"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Webster, Donald R."],"dc:contributor.committeemember":["Roberts, Philip","Weissburg, Marc"],"dc:contributor.department":["Civil and Environmental Engineering"],"dc:contributor.other":["School of Civil and Environmental Engineering","College of Engineering"],"dc:creator":["Chrzan, Joseph Coleman"],"dc:date.accessioned":["2012-09-20T18:22:18Z"],"dc:date.available":["2012-09-20T18:22:18Z"],"dc:date.issued":["2012-07-10"],"dc:description.abstract":["The laser-induced fluorescence (LIF) technique is used to visualize and quantify the concentration field around a conductivity probe. The LIF data are compared to the signal collected by the conductivity probe. The objective is to compare the signal of the contact-sensor to the \"ground-truth\" measurement of the LIF data. Detailed comparison of the temporal response and the peak detection are presented. In addition, a proof-of-concept of a two-color LIF technique is presented using Rhodamine 6G paired with an Argon-ion laser and simultaneously Oxazine 725 paired with a Krypton-ion laser. Optical filters on two digital cameras isolate the emitted light from these respective laser/dye combinations. The objective is to provide detailed quantitation of two over-lapping (non-reactive)chemical plumes."],"dc:description.degree":["MS"],"dc:identifier.uri":["http://hdl.handle.net/1853/44857"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["d69f5efb-5a6a-4324-b538-55bc6b7ba279"],"dc:relation.orgunit":["88639fad-d3ae-4867-9e7a-7c9e6d2ecc7c","7c022d60-21d5-497c-b552-95e489a06569"],"dc:subject":["Conductivity probe","Fluorescence","Lif","Plif"],"dc:subject.lcsh":["Plumes (Fluid dynamics)"],"dc:title":["Laser-induced fluorescence measurements of dual plumes and comparison of laser-induced fluorescence and conductivity probe measurements"],"dc:type":["Text","Thesis"],"dspace:entity.type":["Publication"]},"updated_at":"2026-11-19T06:00:38Z"}