{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/44924"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/44924","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Liquid-phase operation of mems resonators for biochemical sensing in point of care and embedded applications","abstract":"The purpose of this work is the development of MEMS-based resonant sensors for liquid-phase biochemical sensing applications. Specifically, the sensors developed here are aimed at embedded or point-of-sampling applications: (1) when there is not enough time to send a sample to a lab for analysis, (2) in resource-poor settings, (3) when collecting analyte and shipping it to a lab would damage the sample, or (4) for in-situ monitoring. To this end, a bulk micromachined resonant cantilever sensor and a surface micromachined sensor based on the spring-softening effect are investigated as transducer elements. The developed cantilever resonators are operated in an in-plane vibration mode to reduce fluid damping and mass loading by the surrounding fluid. The surface of the resonator is either coated with a chemically sensitive polymer film for chemical sensing or with a layer of protein or antibody for biosensor testing. Chemical tests for sensing volatile organic compounds using polymer-coated in-plane resonators in the liquid-phase give estimated limits of detection below 100 ppb. In addition, biosensor tests for the detection of anti-IgG yield estimated limits of detection around 100 ng/ml. In an attempt to further improve sensor reliability and to further lower the limits of detection, a second sensing concept has been investigated. The presented sensing scheme is capacitive with a resonator acting as an analog-to-digital converter. The resonator and the sensing capacitors are coupled via the spring softening effect. Through this mechanism a change in capacitance causes a shift in resonant frequency. Extensive device modeling has been performed and a process has been developed allowing for fabrication and on-chip packaging of these sensor structures. Initial mechanical characterization data show that the resonators do in fact vibrate.","abstract_html":"The purpose of this work is the development of MEMS-based resonant sensors for liquid-phase biochemical sensing applications. Specifically, the sensors developed here are aimed at embedded or point-of-sampling applications: (1) when there is not enough time to send a sample to a lab for analysis, (2) in resource-poor settings, (3) when collecting analyte and shipping it to a lab would damage the sample, or (4) for in-situ monitoring. To this end, a bulk micromachined resonant cantilever sensor and a surface micromachined sensor based on the spring-softening effect are investigated as transducer elements. The developed cantilever resonators are operated in an in-plane vibration mode to reduce fluid damping and mass loading by the surrounding fluid. The surface of the resonator is either coated with a chemically sensitive polymer film for chemical sensing or with a layer of protein or antibody for biosensor testing. Chemical tests for sensing volatile organic compounds using polymer-coated in-plane resonators in the liquid-phase give estimated limits of detection below 100 ppb. In addition, biosensor tests for the detection of anti-IgG yield estimated limits of detection around 100 ng/ml. In an attempt to further improve sensor reliability and to further lower the limits of detection, a second sensing concept has been investigated. The presented sensing scheme is capacitive with a resonator acting as an analog-to-digital converter. The resonator and the sensing capacitors are coupled via the spring softening effect. Through this mechanism a change in capacitance causes a shift in resonant frequency. Extensive device modeling has been performed and a process has been developed allowing for fabrication and on-chip packaging of these sensor structures. Initial mechanical characterization data show that the resonators do in fact vibrate.","abstract_has_math":false,"creators":["Beardslee, Luke Armitage"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Electrical and Computer Engineering","school":null,"contributors":[],"advisors":["Brand, Oliver"],"committee_chairs":[],"committee_members":["Allen, Mark","Bhatti, Pamela","Frazier, A. Bruno","Lu, Hang"],"year":2011,"date_issued":"2011-07-08","date_published":"2011-07-08","updated_at":"2026-11-19T04:53:54Z","subjects":["Biochemical sensors","Cantilevers","Resonators","Liquid-phase","Chemical sensors","Biosensors","Microelectromechanical systems"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/44924","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/44924","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F44924","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Brand, Oliver"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Allen, Mark","Bhatti, Pamela","Frazier, A. Bruno","Lu, Hang"]},{"key":"dc:contributor.department","label":"Department","values":["Electrical and Computer Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["School of Electrical and Computer Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Beardslee, Luke Armitage"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-09-20T18:24:15Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-09-20T18:24:15Z"]},{"key":"dc:date.issued","label":"Date","values":["2011-07-08"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["4c1c5d47-fca8-482d-87f5-992c88bd5631"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Doctor of Philosophy with a Major in Electrical and Computer Engineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["5b7adef2-447c-4270-b9fc-846bd76f80f2","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["3890cd56-8ecf-424b-8074-8f5ebd8dbe15"]},{"key":"dc:type","label":"Dc Type","values":["Text","Dissertation"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biochemical sensors","Cantilevers","Resonators","Liquid-phase","Chemical sensors","Biosensors"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Microelectromechanical systems"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/44924"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The purpose of this work is the development of MEMS-based resonant sensors for liquid-phase biochemical sensing applications. Specifically, the sensors developed here are aimed at embedded or point-of-sampling applications: (1) when there is not enough time to send a sample to a lab for analysis, (2) in resource-poor settings, (3) when collecting analyte and shipping it to a lab would damage the sample, or (4) for in-situ monitoring. To this end, a bulk micromachined resonant cantilever sensor and a surface micromachined sensor based on the spring-softening effect are investigated as transducer elements. The developed cantilever resonators are operated in an in-plane vibration mode to reduce fluid damping and mass loading by the surrounding fluid. The surface of the resonator is either coated with a chemically sensitive polymer film for chemical sensing or with a layer of protein or antibody for biosensor testing. Chemical tests for sensing volatile organic compounds using polymer-coated in-plane resonators in the liquid-phase give estimated limits of detection below 100 ppb. In addition, biosensor tests for the detection of anti-IgG yield estimated limits of detection around 100 ng/ml. In an attempt to further improve sensor reliability and to further lower the limits of detection, a second sensing concept has been investigated. The presented sensing scheme is capacitive with a resonator acting as an analog-to-digital converter. The resonator and the sensing capacitors are coupled via the spring softening effect. Through this mechanism a change in capacitance causes a shift in resonant frequency. Extensive device modeling has been performed and a process has been developed allowing for fabrication and on-chip packaging of these sensor structures. Initial mechanical characterization data show that the resonators do in fact vibrate."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["PhD"]},{"key":"dc:title","label":"Title","values":["Liquid-phase operation of mems resonators for biochemical sensing in point of care and embedded applications"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Brand, Oliver"],"dc:contributor.committeemember":["Allen, Mark","Bhatti, Pamela","Frazier, A. Bruno","Lu, Hang"],"dc:contributor.department":["Electrical and Computer Engineering"],"dc:contributor.other":["School of Electrical and Computer Engineering","College of Engineering"],"dc:creator":["Beardslee, Luke Armitage"],"dc:date.accessioned":["2012-09-20T18:24:15Z"],"dc:date.available":["2012-09-20T18:24:15Z"],"dc:date.issued":["2011-07-08"],"dc:description.abstract":["The purpose of this work is the development of MEMS-based resonant sensors for liquid-phase biochemical sensing applications. Specifically, the sensors developed here are aimed at embedded or point-of-sampling applications: (1) when there is not enough time to send a sample to a lab for analysis, (2) in resource-poor settings, (3) when collecting analyte and shipping it to a lab would damage the sample, or (4) for in-situ monitoring. To this end, a bulk micromachined resonant cantilever sensor and a surface micromachined sensor based on the spring-softening effect are investigated as transducer elements. The developed cantilever resonators are operated in an in-plane vibration mode to reduce fluid damping and mass loading by the surrounding fluid. The surface of the resonator is either coated with a chemically sensitive polymer film for chemical sensing or with a layer of protein or antibody for biosensor testing. Chemical tests for sensing volatile organic compounds using polymer-coated in-plane resonators in the liquid-phase give estimated limits of detection below 100 ppb. In addition, biosensor tests for the detection of anti-IgG yield estimated limits of detection around 100 ng/ml. In an attempt to further improve sensor reliability and to further lower the limits of detection, a second sensing concept has been investigated. The presented sensing scheme is capacitive with a resonator acting as an analog-to-digital converter. The resonator and the sensing capacitors are coupled via the spring softening effect. Through this mechanism a change in capacitance causes a shift in resonant frequency. Extensive device modeling has been performed and a process has been developed allowing for fabrication and on-chip packaging of these sensor structures. Initial mechanical characterization data show that the resonators do in fact vibrate."],"dc:description.degree":["PhD"],"dc:identifier.uri":["http://hdl.handle.net/1853/44924"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["4c1c5d47-fca8-482d-87f5-992c88bd5631"],"dc:relation.ispartofseries":["Doctor of Philosophy with a Major in Electrical and Computer Engineering"],"dc:relation.orgunit":["5b7adef2-447c-4270-b9fc-846bd76f80f2","7c022d60-21d5-497c-b552-95e489a06569"],"dc:relation.seriesentity":["3890cd56-8ecf-424b-8074-8f5ebd8dbe15"],"dc:subject":["Biochemical sensors","Cantilevers","Resonators","Liquid-phase","Chemical sensors","Biosensors"],"dc:subject.lcsh":["Microelectromechanical systems"],"dc:title":["Liquid-phase operation of mems resonators for biochemical sensing in point of care and embedded applications"],"dc:type":["Text","Dissertation"],"dspace:entity.type":["Publication"]},"updated_at":"2026-11-19T04:53:54Z"}