{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/45741"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/45741","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Functional validation of a novel technique for assembling high density polyimide cochlear implants","abstract":"It has been hypothesized that increasing the number of active sites on a cochlear implant electrode array will enable the recipient to distinguish a higher number of pitch precepts, thus creating a more natural sound. While DSP processing strategies for cochlear implants have evolved significantly to address this, technology for the actual electrode array has remained relatively constant and limits the number of physical electrodes possible. Previous work introduced the concept of using Thin-Film Array (TFA) technology to allow for much higher site densities, although the original devices proved unreliable during surgical insertion tests. This work presents a new method of combining polyimide-based TFA's with supporting silicone insertion platforms to create assembled electrode arrays that are a more viable option for surgical insertion. The electrical and mechanical properties of these assemblies are investigated with physical deformation tests and finite element analysis in COMSOL to quantify how they will perform upon insertion into the cochlea, and the preliminary results of a surgical insertion study into human cadaveric temporal bones will be discussed.","abstract_html":"It has been hypothesized that increasing the number of active sites on a cochlear implant electrode array will enable the recipient to distinguish a higher number of pitch precepts, thus creating a more natural sound. While DSP processing strategies for cochlear implants have evolved significantly to address this, technology for the actual electrode array has remained relatively constant and limits the number of physical electrodes possible. Previous work introduced the concept of using Thin-Film Array (TFA) technology to allow for much higher site densities, although the original devices proved unreliable during surgical insertion tests. This work presents a new method of combining polyimide-based TFA&#x27;s with supporting silicone insertion platforms to create assembled electrode arrays that are a more viable option for surgical insertion. The electrical and mechanical properties of these assemblies are investigated with physical deformation tests and finite element analysis in COMSOL to quantify how they will perform upon insertion into the cochlea, and the preliminary results of a surgical insertion study into human cadaveric temporal bones will be discussed.","abstract_has_math":false,"creators":["Sharpe, Alton Russell"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Electrical and Computer Engineering","school":null,"contributors":[],"advisors":["Bhatti, Pamela T."],"committee_chairs":[],"committee_members":["Burkholder, Thomas","Butera, Robert"],"year":2012,"date_issued":"2012-08-27","date_published":"2012-08-27","updated_at":"2026-11-19T06:03:10Z","subjects":["Cochlear implants","Thin film arrays","COMSOL modeling","Implants, Artificial","Finite element method","Finite element method Computer programs","Thin film devices","Thin films"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/45741","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/45741","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F45741","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Bhatti, Pamela T."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Burkholder, Thomas","Butera, Robert"]},{"key":"dc:contributor.department","label":"Department","values":["Electrical and Computer Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["School of Electrical and Computer Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Sharpe, Alton Russell"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2013-01-17T20:47:34Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2013-01-17T20:47:34Z"]},{"key":"dc:date.issued","label":"Date","values":["2012-08-27"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["de58a4f5-0f0d-4a2c-91f6-bae53faf8e56"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Master of Science in Bioengineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["5b7adef2-447c-4270-b9fc-846bd76f80f2","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["a5c9fe8c-5d03-4de6-a761-459fb2af0dea"]},{"key":"dc:type","label":"Dc Type","values":["Text","Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Cochlear implants","Thin film arrays","COMSOL modeling"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Implants, Artificial","Finite element method","Finite element method Computer programs","Thin film devices","Thin films"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/45741"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["It has been hypothesized that increasing the number of active sites on a cochlear implant electrode array will enable the recipient to distinguish a higher number of pitch precepts, thus creating a more natural sound. While DSP processing strategies for cochlear implants have evolved significantly to address this, technology for the actual electrode array has remained relatively constant and limits the number of physical electrodes possible. Previous work introduced the concept of using Thin-Film Array (TFA) technology to allow for much higher site densities, although the original devices proved unreliable during surgical insertion tests. This work presents a new method of combining polyimide-based TFA's with supporting silicone insertion platforms to create assembled electrode arrays that are a more viable option for surgical insertion. The electrical and mechanical properties of these assemblies are investigated with physical deformation tests and finite element analysis in COMSOL to quantify how they will perform upon insertion into the cochlea, and the preliminary results of a surgical insertion study into human cadaveric temporal bones will be discussed."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["MS"]},{"key":"dc:title","label":"Title","values":["Functional validation of a novel technique for assembling high density polyimide cochlear implants"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Bhatti, Pamela T."],"dc:contributor.committeemember":["Burkholder, Thomas","Butera, Robert"],"dc:contributor.department":["Electrical and Computer Engineering"],"dc:contributor.other":["School of Electrical and Computer Engineering","College of Engineering"],"dc:creator":["Sharpe, Alton Russell"],"dc:date.accessioned":["2013-01-17T20:47:34Z"],"dc:date.available":["2013-01-17T20:47:34Z"],"dc:date.issued":["2012-08-27"],"dc:description.abstract":["It has been hypothesized that increasing the number of active sites on a cochlear implant electrode array will enable the recipient to distinguish a higher number of pitch precepts, thus creating a more natural sound. While DSP processing strategies for cochlear implants have evolved significantly to address this, technology for the actual electrode array has remained relatively constant and limits the number of physical electrodes possible. Previous work introduced the concept of using Thin-Film Array (TFA) technology to allow for much higher site densities, although the original devices proved unreliable during surgical insertion tests. This work presents a new method of combining polyimide-based TFA's with supporting silicone insertion platforms to create assembled electrode arrays that are a more viable option for surgical insertion. The electrical and mechanical properties of these assemblies are investigated with physical deformation tests and finite element analysis in COMSOL to quantify how they will perform upon insertion into the cochlea, and the preliminary results of a surgical insertion study into human cadaveric temporal bones will be discussed."],"dc:description.degree":["MS"],"dc:identifier.uri":["http://hdl.handle.net/1853/45741"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["de58a4f5-0f0d-4a2c-91f6-bae53faf8e56"],"dc:relation.ispartofseries":["Master of Science in Bioengineering"],"dc:relation.orgunit":["5b7adef2-447c-4270-b9fc-846bd76f80f2","7c022d60-21d5-497c-b552-95e489a06569"],"dc:relation.seriesentity":["a5c9fe8c-5d03-4de6-a761-459fb2af0dea"],"dc:subject":["Cochlear implants","Thin film arrays","COMSOL modeling"],"dc:subject.lcsh":["Implants, Artificial","Finite element method","Finite element method Computer programs","Thin film devices","Thin films"],"dc:title":["Functional validation of a novel technique for assembling high density polyimide cochlear implants"],"dc:type":["Text","Thesis"],"dspace:entity.type":["Publication"]},"updated_at":"2026-11-19T06:03:10Z"}