{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/45787"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/45787","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Energy-efficient digital design of reliable, low-throughput wireless biomedical systems","abstract":"The main objective of this research is to improve the energy efficiency of low throughput wireless biomedical systems by employing digital design techniques. The power consumed in conventional wireless EEG (biomedical) systems is dominated by digital microcontroller and the radio frequency (RF) transceiver. To reduce the power associated with the digital processor, data compression can reduce the volume of data transmitted. An adaptive data compression algorithm has been proposed to ensure accurate representations of critical epileptic signals, while also preserving the overall power. Further advances in power reduction are also presented by designing a custom baseband processor for data compression. A functional system has been hardware verified and ASIC optimized to reduce the power by over 9X compared to existing methods. The optimized processor can operate at 32MHz with a near threshold supply of 0.5V in a conventional 45nm technology. While attempting to reach high frequencies in the near threshold regime, the probability of timing violations can reduce the robustness of the system. To further optimize the implementation, a low voltage clock tree design has been investigated to improve the reliability of the digital processor. By implementing the proposed clock tree design methodology, the digital processor can improve its robustness (by reducing the probability of timing violations) while reducing the overall power by more than 5 percent. Future work suggests examining new architectures for low-throughput processing and investigating the proposed systems' potential for a multi-channel EEG implementation.","abstract_html":"The main objective of this research is to improve the energy efficiency of low throughput wireless biomedical systems by employing digital design techniques. The power consumed in conventional wireless EEG (biomedical) systems is dominated by digital microcontroller and the radio frequency (RF) transceiver. To reduce the power associated with the digital processor, data compression can reduce the volume of data transmitted. An adaptive data compression algorithm has been proposed to ensure accurate representations of critical epileptic signals, while also preserving the overall power. Further advances in power reduction are also presented by designing a custom baseband processor for data compression. A functional system has been hardware verified and ASIC optimized to reduce the power by over 9X compared to existing methods. The optimized processor can operate at 32MHz with a near threshold supply of 0.5V in a conventional 45nm technology. While attempting to reach high frequencies in the near threshold regime, the probability of timing violations can reduce the robustness of the system. To further optimize the implementation, a low voltage clock tree design has been investigated to improve the reliability of the digital processor. By implementing the proposed clock tree design methodology, the digital processor can improve its robustness (by reducing the probability of timing violations) while reducing the overall power by more than 5 percent. Future work suggests examining new architectures for low-throughput processing and investigating the proposed systems&#x27; potential for a multi-channel EEG implementation.","abstract_has_math":false,"creators":["Tolbert, Jeremy Reynard"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Electrical and Computer Engineering","school":null,"contributors":[],"advisors":["Mukhopadhyay, Saibal"],"committee_chairs":[],"committee_members":["Ghovanloo, Maysam","Kim, Hyesoon","Lee, Hsien-Hsin","Lim, Sung Kyu"],"year":2012,"date_issued":"2012-08-24","date_published":"2012-08-24","updated_at":"2026-11-19T04:13:11Z","subjects":["EEG","Digital design","Subthreshold","Low power","Data compression","Energy-efficiency","Wireless systems","Medical electronics","Energy consumption","Data compression (Computer science)","Electroencephalography"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/45787","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/45787","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F45787","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Mukhopadhyay, Saibal"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Ghovanloo, Maysam","Kim, Hyesoon","Lee, Hsien-Hsin","Lim, Sung Kyu"]},{"key":"dc:contributor.department","label":"Department","values":["Electrical and Computer Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["School of Electrical and Computer Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Tolbert, Jeremy Reynard"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2013-01-17T21:04:46Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2013-01-17T21:04:46Z"]},{"key":"dc:date.issued","label":"Date","values":["2012-08-24"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["62df0580-589a-4599-98af-88783123945a"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Doctor of Philosophy with a Major in Electrical and Computer Engineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["5b7adef2-447c-4270-b9fc-846bd76f80f2","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["3890cd56-8ecf-424b-8074-8f5ebd8dbe15"]},{"key":"dc:type","label":"Dc Type","values":["Text","Dissertation"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["EEG","Digital design","Subthreshold","Low power","Data compression","Energy-efficiency","Wireless systems"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Medical electronics","Energy consumption","Data compression (Computer science)","Electroencephalography"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/45787"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The main objective of this research is to improve the energy efficiency of low throughput wireless biomedical systems by employing digital design techniques. The power consumed in conventional wireless EEG (biomedical) systems is dominated by digital microcontroller and the radio frequency (RF) transceiver. To reduce the power associated with the digital processor, data compression can reduce the volume of data transmitted. An adaptive data compression algorithm has been proposed to ensure accurate representations of critical epileptic signals, while also preserving the overall power. Further advances in power reduction are also presented by designing a custom baseband processor for data compression. A functional system has been hardware verified and ASIC optimized to reduce the power by over 9X compared to existing methods. The optimized processor can operate at 32MHz with a near threshold supply of 0.5V in a conventional 45nm technology. While attempting to reach high frequencies in the near threshold regime, the probability of timing violations can reduce the robustness of the system. To further optimize the implementation, a low voltage clock tree design has been investigated to improve the reliability of the digital processor. By implementing the proposed clock tree design methodology, the digital processor can improve its robustness (by reducing the probability of timing violations) while reducing the overall power by more than 5 percent. Future work suggests examining new architectures for low-throughput processing and investigating the proposed systems' potential for a multi-channel EEG implementation."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["PhD"]},{"key":"dc:title","label":"Title","values":["Energy-efficient digital design of reliable, low-throughput wireless biomedical systems"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Mukhopadhyay, Saibal"],"dc:contributor.committeemember":["Ghovanloo, Maysam","Kim, Hyesoon","Lee, Hsien-Hsin","Lim, Sung Kyu"],"dc:contributor.department":["Electrical and Computer Engineering"],"dc:contributor.other":["School of Electrical and Computer Engineering","College of Engineering"],"dc:creator":["Tolbert, Jeremy Reynard"],"dc:date.accessioned":["2013-01-17T21:04:46Z"],"dc:date.available":["2013-01-17T21:04:46Z"],"dc:date.issued":["2012-08-24"],"dc:description.abstract":["The main objective of this research is to improve the energy efficiency of low throughput wireless biomedical systems by employing digital design techniques. The power consumed in conventional wireless EEG (biomedical) systems is dominated by digital microcontroller and the radio frequency (RF) transceiver. To reduce the power associated with the digital processor, data compression can reduce the volume of data transmitted. An adaptive data compression algorithm has been proposed to ensure accurate representations of critical epileptic signals, while also preserving the overall power. Further advances in power reduction are also presented by designing a custom baseband processor for data compression. A functional system has been hardware verified and ASIC optimized to reduce the power by over 9X compared to existing methods. The optimized processor can operate at 32MHz with a near threshold supply of 0.5V in a conventional 45nm technology. While attempting to reach high frequencies in the near threshold regime, the probability of timing violations can reduce the robustness of the system. To further optimize the implementation, a low voltage clock tree design has been investigated to improve the reliability of the digital processor. By implementing the proposed clock tree design methodology, the digital processor can improve its robustness (by reducing the probability of timing violations) while reducing the overall power by more than 5 percent. Future work suggests examining new architectures for low-throughput processing and investigating the proposed systems' potential for a multi-channel EEG implementation."],"dc:description.degree":["PhD"],"dc:identifier.uri":["http://hdl.handle.net/1853/45787"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["62df0580-589a-4599-98af-88783123945a"],"dc:relation.ispartofseries":["Doctor of Philosophy with a Major in Electrical and Computer Engineering"],"dc:relation.orgunit":["5b7adef2-447c-4270-b9fc-846bd76f80f2","7c022d60-21d5-497c-b552-95e489a06569"],"dc:relation.seriesentity":["3890cd56-8ecf-424b-8074-8f5ebd8dbe15"],"dc:subject":["EEG","Digital design","Subthreshold","Low power","Data compression","Energy-efficiency","Wireless systems"],"dc:subject.lcsh":["Medical electronics","Energy consumption","Data compression (Computer science)","Electroencephalography"],"dc:title":["Energy-efficient digital design of reliable, low-throughput wireless biomedical systems"],"dc:type":["Text","Dissertation"],"dspace:entity.type":["Publication"]},"updated_at":"2026-11-19T04:13:11Z"}