{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/45842"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/45842","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Investigation of noise in hospital emergency departments","abstract":"The hospital sound environment is complex. Emergency Departments (EDs), in particular, have proven to be hectic work environments populated with diverse sound sources. Medical equipment, alarms, and communication events generate noise that can interfere with staff concentration and communication. In this study, sound measurements and analyses were conducted in six hospitals total: three civilian hospitals in Atlanta, Georgia and Dublin, Ohio, as well as three Washington, DC-area hospitals in the Military Health System (MHS). The equivalent, minimum, and maximum sound pressure levels were recorded over twenty-four hours in several locations in each ED, with shorter 15-30 minute measurements performed in other areas. Acoustic descriptors, such as spectral content, level distributions, and speech intelligibility were examined. The perception of these acoustic qualities by hospital staff was also evaluated through subjective surveys. It was found that noise levels in both work areas and patient rooms were excessive. Additionally, speech intelligibility measurements and survey results show that background noise presents a significant obstacle in effective communication between staff members and patients. Compared to previous studies, this study looks at a wider range of acoustic metrics and the corresponding perceptions of staff in order to form a more precise and accurate depiction of the ED sound environment.","abstract_html":"The hospital sound environment is complex. Emergency Departments (EDs), in particular, have proven to be hectic work environments populated with diverse sound sources. Medical equipment, alarms, and communication events generate noise that can interfere with staff concentration and communication. In this study, sound measurements and analyses were conducted in six hospitals total: three civilian hospitals in Atlanta, Georgia and Dublin, Ohio, as well as three Washington, DC-area hospitals in the Military Health System (MHS). The equivalent, minimum, and maximum sound pressure levels were recorded over twenty-four hours in several locations in each ED, with shorter 15-30 minute measurements performed in other areas. Acoustic descriptors, such as spectral content, level distributions, and speech intelligibility were examined. The perception of these acoustic qualities by hospital staff was also evaluated through subjective surveys. It was found that noise levels in both work areas and patient rooms were excessive. Additionally, speech intelligibility measurements and survey results show that background noise presents a significant obstacle in effective communication between staff members and patients. Compared to previous studies, this study looks at a wider range of acoustic metrics and the corresponding perceptions of staff in order to form a more precise and accurate depiction of the ED sound environment.","abstract_has_math":false,"creators":["Mahapatra, Arun Kiran"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["Ryherd, Erica E."],"committee_chairs":[],"committee_members":["Ackerman, Jeremy","Sabra, Karim"],"year":2011,"date_issued":"2011-11-08","date_published":"2011-11-08","updated_at":"2026-11-19T05:52:50Z","subjects":["Perception of noise","Passive room impulse response","Speech intelligibility","Impulse response","Background noise","Emergency department","Occurrence rate","Noise control","Noise","Sound Measurement","Auditory perception","Auditory scene analysis"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/45842","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/45842","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F45842","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Ryherd, Erica E."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Ackerman, Jeremy","Sabra, Karim"]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["George W. Woodruff School of Mechanical Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Mahapatra, Arun Kiran"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2013-01-17T21:46:37Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2013-01-17T21:46:37Z"]},{"key":"dc:date.issued","label":"Date","values":["2011-11-08"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Master of Science in Mechanical Engineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["c01ff908-c25f-439b-bf10-a074ed886bb7","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["028ba2d8-6c6e-4f8a-a480-51b555d14e9d"]},{"key":"dc:type","label":"Dc Type","values":["Text","Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Perception of noise","Passive room impulse response","Speech intelligibility","Impulse response","Background noise","Emergency department","Occurrence rate"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Noise control","Noise","Sound Measurement","Auditory perception","Auditory scene analysis"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/45842"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The hospital sound environment is complex. Emergency Departments (EDs), in particular, have proven to be hectic work environments populated with diverse sound sources. Medical equipment, alarms, and communication events generate noise that can interfere with staff concentration and communication. In this study, sound measurements and analyses were conducted in six hospitals total: three civilian hospitals in Atlanta, Georgia and Dublin, Ohio, as well as three Washington, DC-area hospitals in the Military Health System (MHS). The equivalent, minimum, and maximum sound pressure levels were recorded over twenty-four hours in several locations in each ED, with shorter 15-30 minute measurements performed in other areas. Acoustic descriptors, such as spectral content, level distributions, and speech intelligibility were examined. The perception of these acoustic qualities by hospital staff was also evaluated through subjective surveys. It was found that noise levels in both work areas and patient rooms were excessive. Additionally, speech intelligibility measurements and survey results show that background noise presents a significant obstacle in effective communication between staff members and patients. Compared to previous studies, this study looks at a wider range of acoustic metrics and the corresponding perceptions of staff in order to form a more precise and accurate depiction of the ED sound environment."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["MS"]},{"key":"dc:title","label":"Title","values":["Investigation of noise in hospital emergency departments"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Ryherd, Erica E."],"dc:contributor.committeemember":["Ackerman, Jeremy","Sabra, Karim"],"dc:contributor.department":["Mechanical Engineering"],"dc:contributor.other":["George W. Woodruff School of Mechanical Engineering","College of Engineering"],"dc:creator":["Mahapatra, Arun Kiran"],"dc:date.accessioned":["2013-01-17T21:46:37Z"],"dc:date.available":["2013-01-17T21:46:37Z"],"dc:date.issued":["2011-11-08"],"dc:description.abstract":["The hospital sound environment is complex. Emergency Departments (EDs), in particular, have proven to be hectic work environments populated with diverse sound sources. Medical equipment, alarms, and communication events generate noise that can interfere with staff concentration and communication. In this study, sound measurements and analyses were conducted in six hospitals total: three civilian hospitals in Atlanta, Georgia and Dublin, Ohio, as well as three Washington, DC-area hospitals in the Military Health System (MHS). The equivalent, minimum, and maximum sound pressure levels were recorded over twenty-four hours in several locations in each ED, with shorter 15-30 minute measurements performed in other areas. Acoustic descriptors, such as spectral content, level distributions, and speech intelligibility were examined. The perception of these acoustic qualities by hospital staff was also evaluated through subjective surveys. It was found that noise levels in both work areas and patient rooms were excessive. Additionally, speech intelligibility measurements and survey results show that background noise presents a significant obstacle in effective communication between staff members and patients. Compared to previous studies, this study looks at a wider range of acoustic metrics and the corresponding perceptions of staff in order to form a more precise and accurate depiction of the ED sound environment."],"dc:description.degree":["MS"],"dc:identifier.uri":["http://hdl.handle.net/1853/45842"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.ispartofseries":["Master of Science in Mechanical Engineering"],"dc:relation.orgunit":["c01ff908-c25f-439b-bf10-a074ed886bb7","7c022d60-21d5-497c-b552-95e489a06569"],"dc:relation.seriesentity":["028ba2d8-6c6e-4f8a-a480-51b555d14e9d"],"dc:subject":["Perception of noise","Passive room impulse response","Speech intelligibility","Impulse response","Background noise","Emergency department","Occurrence rate"],"dc:subject.lcsh":["Noise control","Noise","Sound Measurement","Auditory perception","Auditory scene analysis"],"dc:title":["Investigation of noise in hospital emergency departments"],"dc:type":["Text","Thesis"],"dspace:entity.type":["Publication"]},"updated_at":"2026-11-19T05:52:50Z"}