{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/4882"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/4882","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"A Mechanical Fluid Assessment of Anatomical Models of the Total Cavopulmonary Connection (TCPC)","abstract":"BACKGROUND: Understanding the hemodynamics of the total cavopulmonary connection (TCPC) may lead to further optimization of the connection design and surgical planning, which in turn may lead to improved surgical outcome. While most experimental and numerical investigations have mainly focused on somewhat simplified geometries, the investigation of the flow field of true TCPC configurations is necessary for a true understanding. METHODS: This study details a manufacturing methodology yielding more accurate in vitro models that would provide a better understanding of the TCPC hemodynamics and adequate data for the validation of anatomical CFD simulations. This approach is illustrated on two different TCPC templates: an intra-atrial TCPC with a single superior vena cava (SVC) and a bilateral SVC with an extra-cardiac conduit. Power loss, flow visualization, digital particle image velocimetry (DPIV) flow measurements as well as computational fluid dynamics simulations are performed to characterize the anatomic flow structure. Additional parametric glass models of the TCPC were manufactured to help understand the fluid dynamics of the anatomical models and support the computational model validation effort. RESULTS/CONCLUSIONS: Both anatomic configurations revealed very different fluid dynamics underlining once again the need for at least one comprehensive experimental campaign per TCPC template for a good understanding of the flow phenomena. The absence of caval offset in the anatomical intra-atrial model resulted in important flow turbulence, which was enhanced by the large connection area and yielded high pressure drops and power losses. On the other hand, the bilateral SVC, which featured a smooth extra-cardiac conduit and wider vessels, led to power losses that were one order of magnitude lower than those of the anatomic intra-atrial model and a smooth flow field with lower levels of instability. The simplified glass models demonstrated that the diameter of the connecting vessels and of the pulmonary arteries in particular, was a parameter of prime importance. Finally, this study also reports on a combined experimental and numerical validation methodology, suggesting a cautious approach for the straightforward use of available CFD tools and pointing out the need for developing high resolution CFD techniques specifically tailored to tackle the complexities of cardiovascular flows.","abstract_html":"BACKGROUND: Understanding the hemodynamics of the total cavopulmonary connection (TCPC) may lead to further optimization of the connection design and surgical planning, which in turn may lead to improved surgical outcome. While most experimental and numerical investigations have mainly focused on somewhat simplified geometries, the investigation of the flow field of true TCPC configurations is necessary for a true understanding. METHODS: This study details a manufacturing methodology yielding more accurate in vitro models that would provide a better understanding of the TCPC hemodynamics and adequate data for the validation of anatomical CFD simulations. This approach is illustrated on two different TCPC templates: an intra-atrial TCPC with a single superior vena cava (SVC) and a bilateral SVC with an extra-cardiac conduit. Power loss, flow visualization, digital particle image velocimetry (DPIV) flow measurements as well as computational fluid dynamics simulations are performed to characterize the anatomic flow structure. Additional parametric glass models of the TCPC were manufactured to help understand the fluid dynamics of the anatomical models and support the computational model validation effort. RESULTS/CONCLUSIONS: Both anatomic configurations revealed very different fluid dynamics underlining once again the need for at least one comprehensive experimental campaign per TCPC template for a good understanding of the flow phenomena. The absence of caval offset in the anatomical intra-atrial model resulted in important flow turbulence, which was enhanced by the large connection area and yielded high pressure drops and power losses. On the other hand, the bilateral SVC, which featured a smooth extra-cardiac conduit and wider vessels, led to power losses that were one order of magnitude lower than those of the anatomic intra-atrial model and a smooth flow field with lower levels of instability. The simplified glass models demonstrated that the diameter of the connecting vessels and of the pulmonary arteries in particular, was a parameter of prime importance. Finally, this study also reports on a combined experimental and numerical validation methodology, suggesting a cautious approach for the straightforward use of available CFD tools and pointing out the need for developing high resolution CFD techniques specifically tailored to tackle the complexities of cardiovascular flows.","abstract_has_math":false,"creators":["de Julien de Zelicourt, Diane Alicia"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Biomedical Engineering","school":null,"contributors":[],"advisors":["Yoganathan, Ajit P."],"committee_chairs":[],"committee_members":["Don Giddens","Shiva Sharma"],"year":2004,"date_issued":"2004-12-09","date_published":"2004-12-09","updated_at":"2026-11-19T03:57:19Z","subjects":["Intra-atrial","Extra-cardiac","Bilateral SVC","In vitro experiments","TCPC","Fontan","DPIV","Power losses"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/4882","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/4882","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F4882","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Yoganathan, Ajit P."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Don Giddens","Shiva Sharma"]},{"key":"dc:contributor.department","label":"Department","values":["Biomedical Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Wallace H. Coulter Department of Biomedical Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["de Julien de Zelicourt, Diane Alicia"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2005-03-01T19:38:06Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2005-03-01T19:38:06Z"]},{"key":"dc:date.issued","label":"Date","values":["2004-12-09"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["6a910742-4bed-4ba6-b03d-f92e4c915a00"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Master of Science in Bioengineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["da59be3c-3d0a-41da-91b9-ebe2ecc83b66","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["a5c9fe8c-5d03-4de6-a761-459fb2af0dea"]},{"key":"dc:type","label":"Dc Type","values":["Text","Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Intra-atrial","Extra-cardiac","Bilateral SVC","In vitro experiments","TCPC","Fontan","DPIV","Power losses"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/4882"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["BACKGROUND: Understanding the hemodynamics of the total cavopulmonary connection (TCPC) may lead to further optimization of the connection design and surgical planning, which in turn may lead to improved surgical outcome. While most experimental and numerical investigations have mainly focused on somewhat simplified geometries, the investigation of the flow field of true TCPC configurations is necessary for a true understanding. METHODS: This study details a manufacturing methodology yielding more accurate in vitro models that would provide a better understanding of the TCPC hemodynamics and adequate data for the validation of anatomical CFD simulations. This approach is illustrated on two different TCPC templates: an intra-atrial TCPC with a single superior vena cava (SVC) and a bilateral SVC with an extra-cardiac conduit. Power loss, flow visualization, digital particle image velocimetry (DPIV) flow measurements as well as computational fluid dynamics simulations are performed to characterize the anatomic flow structure. Additional parametric glass models of the TCPC were manufactured to help understand the fluid dynamics of the anatomical models and support the computational model validation effort. RESULTS/CONCLUSIONS: Both anatomic configurations revealed very different fluid dynamics underlining once again the need for at least one comprehensive experimental campaign per TCPC template for a good understanding of the flow phenomena. The absence of caval offset in the anatomical intra-atrial model resulted in important flow turbulence, which was enhanced by the large connection area and yielded high pressure drops and power losses. On the other hand, the bilateral SVC, which featured a smooth extra-cardiac conduit and wider vessels, led to power losses that were one order of magnitude lower than those of the anatomic intra-atrial model and a smooth flow field with lower levels of instability. The simplified glass models demonstrated that the diameter of the connecting vessels and of the pulmonary arteries in particular, was a parameter of prime importance. Finally, this study also reports on a combined experimental and numerical validation methodology, suggesting a cautious approach for the straightforward use of available CFD tools and pointing out the need for developing high resolution CFD techniques specifically tailored to tackle the complexities of cardiovascular flows."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.S."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["83739 bytes","43198 bytes","1396937 bytes","146950 bytes","112991 bytes","188297 bytes","151904 bytes","161682 bytes","12287922 bytes"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["video/quicktime","application/pdf"]},{"key":"dc:title","label":"Title","values":["A Mechanical Fluid Assessment of Anatomical Models of the Total Cavopulmonary Connection (TCPC)"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Yoganathan, Ajit P."],"dc:contributor.committeemember":["Don Giddens","Shiva Sharma"],"dc:contributor.department":["Biomedical Engineering"],"dc:contributor.other":["Wallace H. Coulter Department of Biomedical Engineering","College of Engineering"],"dc:creator":["de Julien de Zelicourt, Diane Alicia"],"dc:date.accessioned":["2005-03-01T19:38:06Z"],"dc:date.available":["2005-03-01T19:38:06Z"],"dc:date.issued":["2004-12-09"],"dc:description.abstract":["BACKGROUND: Understanding the hemodynamics of the total cavopulmonary connection (TCPC) may lead to further optimization of the connection design and surgical planning, which in turn may lead to improved surgical outcome. While most experimental and numerical investigations have mainly focused on somewhat simplified geometries, the investigation of the flow field of true TCPC configurations is necessary for a true understanding. METHODS: This study details a manufacturing methodology yielding more accurate in vitro models that would provide a better understanding of the TCPC hemodynamics and adequate data for the validation of anatomical CFD simulations. This approach is illustrated on two different TCPC templates: an intra-atrial TCPC with a single superior vena cava (SVC) and a bilateral SVC with an extra-cardiac conduit. Power loss, flow visualization, digital particle image velocimetry (DPIV) flow measurements as well as computational fluid dynamics simulations are performed to characterize the anatomic flow structure. Additional parametric glass models of the TCPC were manufactured to help understand the fluid dynamics of the anatomical models and support the computational model validation effort. RESULTS/CONCLUSIONS: Both anatomic configurations revealed very different fluid dynamics underlining once again the need for at least one comprehensive experimental campaign per TCPC template for a good understanding of the flow phenomena. The absence of caval offset in the anatomical intra-atrial model resulted in important flow turbulence, which was enhanced by the large connection area and yielded high pressure drops and power losses. On the other hand, the bilateral SVC, which featured a smooth extra-cardiac conduit and wider vessels, led to power losses that were one order of magnitude lower than those of the anatomic intra-atrial model and a smooth flow field with lower levels of instability. The simplified glass models demonstrated that the diameter of the connecting vessels and of the pulmonary arteries in particular, was a parameter of prime importance. Finally, this study also reports on a combined experimental and numerical validation methodology, suggesting a cautious approach for the straightforward use of available CFD tools and pointing out the need for developing high resolution CFD techniques specifically tailored to tackle the complexities of cardiovascular flows."],"dc:description.degree":["M.S."],"dc:format.extent":["83739 bytes","43198 bytes","1396937 bytes","146950 bytes","112991 bytes","188297 bytes","151904 bytes","161682 bytes","12287922 bytes"],"dc:format.mimetype":["video/quicktime","application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1853/4882"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["6a910742-4bed-4ba6-b03d-f92e4c915a00"],"dc:relation.ispartofseries":["Master of Science in Bioengineering"],"dc:relation.orgunit":["da59be3c-3d0a-41da-91b9-ebe2ecc83b66","7c022d60-21d5-497c-b552-95e489a06569"],"dc:relation.seriesentity":["a5c9fe8c-5d03-4de6-a761-459fb2af0dea"],"dc:subject":["Intra-atrial","Extra-cardiac","Bilateral SVC","In vitro experiments","TCPC","Fontan","DPIV","Power losses"],"dc:title":["A Mechanical Fluid Assessment of Anatomical Models of the Total Cavopulmonary Connection (TCPC)"],"dc:type":["Text","Thesis"],"dspace:entity.type":["Publication"]},"updated_at":"2026-11-19T03:57:19Z"}