{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/4890"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/4890","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Measurement of Finned-Tube Heat Exchanger Performance","abstract":"Finned-tube heat exchangers are predominantly used in space conditioning systems, as well as other applications requiring heat exchange between two fluids. One important widespread use is in residential air conditioning systems. These residential cooling systems influence the peak demand on the U.S. national electrical system, which occurs on the hot summer afternoons, and thereby sets the requirement for the expensive infrastructure requirement of the nations power plant and electrical distribution system. In addition to this peak demand, these residential air conditioners are major energy users that dominate residential electrical costs and environmental impact. The design of finned-tube heat exchangers requires the selection of over a dozen design parameters by the designer. The refrigerant side flow and heat transfer characteristics inside the tubes have been thoroughly studied. However, the air side flow around the tube bundle and through the fin gaps is much more complex and depends on over a dozen design parameters. Therefore, experimental measurement of the air side performance is needed. First this study built an experimental system and developed methodology for measuring the air side heat transfer and pressure drop characteristics of fin tube heat exchangers. This capability was then used to continue the goal of expanding and clarifying the present knowledge and understanding of air side performance to enable the air conditioner system designer in verifying an optimum fin tube condenser design. In this study eight fin tube heat exchangers were tested over an air flow face velocity range of 5 ?? ft/s (675-1600cfm). The raw data were reduced to the desired heat transfer and friction data, j and f factors. This reduced heat transfer and friction data was plotted versus Reynolds number and compared. The effect of fin spacing, the number of rows and fin enhancement were all investigated. The heat transfer and friction data were also plotted and compared with various correlations available from open literature. The overall accuracy of each correlation to predict experimental data was calculated. Correlations by C.C. Wang (1998b, 1999) showed the best agreement with the data. Wangs correlations (1998b, 1999) were modified to fit the current studys data.","abstract_html":"Finned-tube heat exchangers are predominantly used in space conditioning systems, as well as other applications requiring heat exchange between two fluids. One important widespread use is in residential air conditioning systems. These residential cooling systems influence the peak demand on the U.S. national electrical system, which occurs on the hot summer afternoons, and thereby sets the requirement for the expensive infrastructure requirement of the nations power plant and electrical distribution system. In addition to this peak demand, these residential air conditioners are major energy users that dominate residential electrical costs and environmental impact. The design of finned-tube heat exchangers requires the selection of over a dozen design parameters by the designer. The refrigerant side flow and heat transfer characteristics inside the tubes have been thoroughly studied. However, the air side flow around the tube bundle and through the fin gaps is much more complex and depends on over a dozen design parameters. Therefore, experimental measurement of the air side performance is needed. First this study built an experimental system and developed methodology for measuring the air side heat transfer and pressure drop characteristics of fin tube heat exchangers. This capability was then used to continue the goal of expanding and clarifying the present knowledge and understanding of air side performance to enable the air conditioner system designer in verifying an optimum fin tube condenser design. In this study eight fin tube heat exchangers were tested over an air flow face velocity range of 5 ?? ft/s (675-1600cfm). The raw data were reduced to the desired heat transfer and friction data, j and f factors. This reduced heat transfer and friction data was plotted versus Reynolds number and compared. The effect of fin spacing, the number of rows and fin enhancement were all investigated. The heat transfer and friction data were also plotted and compared with various correlations available from open literature. The overall accuracy of each correlation to predict experimental data was calculated. Correlations by C.C. Wang (1998b, 1999) showed the best agreement with the data. Wangs correlations (1998b, 1999) were modified to fit the current studys data.","abstract_has_math":false,"creators":["Taylor, Creed"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["Shelton, Samuel V."],"committee_chairs":[],"committee_members":["Jeter, Sheldon M.","Garimella, Srinivas"],"year":2004,"date_issued":"2004-12-01","date_published":"2004-12-01","updated_at":"2026-11-19T05:02:15Z","subjects":["Heat Exchanger","Finned-Tube","Heat Transmission Testing","Tubes Fluid dynamics Testing","Air conditioning Design and construction","Heat exchangers Testing"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/4890","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/4890","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F4890","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Shelton, Samuel V."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Jeter, Sheldon M.","Garimella, Srinivas"]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["George W. Woodruff School of Mechanical Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Taylor, Creed"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2005-03-01T19:39:11Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2005-03-01T19:39:11Z"]},{"key":"dc:date.issued","label":"Date","values":["2004-12-01"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Master of Science in Mechanical Engineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["c01ff908-c25f-439b-bf10-a074ed886bb7","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["028ba2d8-6c6e-4f8a-a480-51b555d14e9d"]},{"key":"dc:type","label":"Dc Type","values":["Text","Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Heat Exchanger","Finned-Tube"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Heat Transmission Testing","Tubes Fluid dynamics Testing","Air conditioning Design and construction","Heat exchangers Testing"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/4890"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Finned-tube heat exchangers are predominantly used in space conditioning systems, as well as other applications requiring heat exchange between two fluids. One important widespread use is in residential air conditioning systems. These residential cooling systems influence the peak demand on the U.S. national electrical system, which occurs on the hot summer afternoons, and thereby sets the requirement for the expensive infrastructure requirement of the nations power plant and electrical distribution system. In addition to this peak demand, these residential air conditioners are major energy users that dominate residential electrical costs and environmental impact. The design of finned-tube heat exchangers requires the selection of over a dozen design parameters by the designer. The refrigerant side flow and heat transfer characteristics inside the tubes have been thoroughly studied. However, the air side flow around the tube bundle and through the fin gaps is much more complex and depends on over a dozen design parameters. Therefore, experimental measurement of the air side performance is needed. First this study built an experimental system and developed methodology for measuring the air side heat transfer and pressure drop characteristics of fin tube heat exchangers. This capability was then used to continue the goal of expanding and clarifying the present knowledge and understanding of air side performance to enable the air conditioner system designer in verifying an optimum fin tube condenser design. In this study eight fin tube heat exchangers were tested over an air flow face velocity range of 5 ?? ft/s (675-1600cfm). The raw data were reduced to the desired heat transfer and friction data, j and f factors. This reduced heat transfer and friction data was plotted versus Reynolds number and compared. The effect of fin spacing, the number of rows and fin enhancement were all investigated. The heat transfer and friction data were also plotted and compared with various correlations available from open literature. The overall accuracy of each correlation to predict experimental data was calculated. Correlations by C.C. Wang (1998b, 1999) showed the best agreement with the data. Wangs correlations (1998b, 1999) were modified to fit the current studys data."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.S."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["2570717 bytes"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Measurement of Finned-Tube Heat Exchanger Performance"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Shelton, Samuel V."],"dc:contributor.committeemember":["Jeter, Sheldon M.","Garimella, Srinivas"],"dc:contributor.department":["Mechanical Engineering"],"dc:contributor.other":["George W. Woodruff School of Mechanical Engineering","College of Engineering"],"dc:creator":["Taylor, Creed"],"dc:date.accessioned":["2005-03-01T19:39:11Z"],"dc:date.available":["2005-03-01T19:39:11Z"],"dc:date.issued":["2004-12-01"],"dc:description.abstract":["Finned-tube heat exchangers are predominantly used in space conditioning systems, as well as other applications requiring heat exchange between two fluids. One important widespread use is in residential air conditioning systems. These residential cooling systems influence the peak demand on the U.S. national electrical system, which occurs on the hot summer afternoons, and thereby sets the requirement for the expensive infrastructure requirement of the nations power plant and electrical distribution system. In addition to this peak demand, these residential air conditioners are major energy users that dominate residential electrical costs and environmental impact. The design of finned-tube heat exchangers requires the selection of over a dozen design parameters by the designer. The refrigerant side flow and heat transfer characteristics inside the tubes have been thoroughly studied. However, the air side flow around the tube bundle and through the fin gaps is much more complex and depends on over a dozen design parameters. Therefore, experimental measurement of the air side performance is needed. First this study built an experimental system and developed methodology for measuring the air side heat transfer and pressure drop characteristics of fin tube heat exchangers. This capability was then used to continue the goal of expanding and clarifying the present knowledge and understanding of air side performance to enable the air conditioner system designer in verifying an optimum fin tube condenser design. In this study eight fin tube heat exchangers were tested over an air flow face velocity range of 5 ?? ft/s (675-1600cfm). The raw data were reduced to the desired heat transfer and friction data, j and f factors. This reduced heat transfer and friction data was plotted versus Reynolds number and compared. The effect of fin spacing, the number of rows and fin enhancement were all investigated. The heat transfer and friction data were also plotted and compared with various correlations available from open literature. The overall accuracy of each correlation to predict experimental data was calculated. Correlations by C.C. Wang (1998b, 1999) showed the best agreement with the data. Wangs correlations (1998b, 1999) were modified to fit the current studys data."],"dc:description.degree":["M.S."],"dc:format.extent":["2570717 bytes"],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1853/4890"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.ispartofseries":["Master of Science in Mechanical Engineering"],"dc:relation.orgunit":["c01ff908-c25f-439b-bf10-a074ed886bb7","7c022d60-21d5-497c-b552-95e489a06569"],"dc:relation.seriesentity":["028ba2d8-6c6e-4f8a-a480-51b555d14e9d"],"dc:subject":["Heat Exchanger","Finned-Tube"],"dc:subject.lcsh":["Heat Transmission Testing","Tubes Fluid dynamics Testing","Air conditioning Design and construction","Heat exchangers Testing"],"dc:title":["Measurement of Finned-Tube Heat Exchanger Performance"],"dc:type":["Text","Thesis"],"dspace:entity.type":["Publication"]},"updated_at":"2026-11-19T05:02:15Z"}