{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/50224"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/50224","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"MRI methods for predicting response to cardiac resynchronization therapy","abstract":"Cardiac Resynchronization Therapy (CRT) is a treatment option for heart failure patients with ventricular dyssynchrony. CRT corrects for dyssynchrony by electrically stimulating the septal and lateral walls of the left ventricle (LV), forcing synchronous con- traction and improving cardiac output. Current selection criteria for CRT rely upon the QRS duration, measured from a surface electrocardiogram, as a marker of electrical dyssynchrony. Unfortunately, 30-40% of patients undergoing CRT fail to benefit from the treatment. A multitude of studies have shown that presence of mechanical dyssynchrony in the LV is an important factor in determining if a patient will benefit from CRT. Furthermore, recent evidence suggests that patient response can be improved by placing the LV pacing lead in the most dyssynchronous or latest contracting segment. The overall goal of this project was to develop methods that allow for accurate assessment and display of regional mechanical dyssynchrony throughout the LV and at the site of the LV pacing lead. To accomplish this goal, we developed a method for quantifying regional dyssynchrony from standard short-axis cine magnetic resonance (MR) images. To assess the effects of LV lead placement, we developed a registration method that allows us to project the LV lead location from dual-plane fluoroscopy onto MR measurements of cardiac function. By applying these techniques in patients undergoing CRT, we were able to investigate the relationship between regional dyssynchrony, LV pacing lead location, and CRT response.","abstract_html":"Cardiac Resynchronization Therapy (CRT) is a treatment option for heart failure patients with ventricular dyssynchrony. CRT corrects for dyssynchrony by electrically stimulating the septal and lateral walls of the left ventricle (LV), forcing synchronous con- traction and improving cardiac output. Current selection criteria for CRT rely upon the QRS duration, measured from a surface electrocardiogram, as a marker of electrical dyssynchrony. Unfortunately, 30-40% of patients undergoing CRT fail to benefit from the treatment. A multitude of studies have shown that presence of mechanical dyssynchrony in the LV is an important factor in determining if a patient will benefit from CRT. Furthermore, recent evidence suggests that patient response can be improved by placing the LV pacing lead in the most dyssynchronous or latest contracting segment. The overall goal of this project was to develop methods that allow for accurate assessment and display of regional mechanical dyssynchrony throughout the LV and at the site of the LV pacing lead. To accomplish this goal, we developed a method for quantifying regional dyssynchrony from standard short-axis cine magnetic resonance (MR) images. To assess the effects of LV lead placement, we developed a registration method that allows us to project the LV lead location from dual-plane fluoroscopy onto MR measurements of cardiac function. By applying these techniques in patients undergoing CRT, we were able to investigate the relationship between regional dyssynchrony, LV pacing lead location, and CRT response.","abstract_has_math":false,"creators":["Suever, Jonathan D."],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Doctoral","degree_discipline":null,"degree_department":"Biomedical Engineering (Joint GT/Emory Department)","school":null,"contributors":[],"advisors":["Oshinski, John N."],"committee_chairs":[],"committee_members":["Brummer, Marijn E.","Lloyd, Michael S.","Sechopoulos, Ioannis","Tang, Xiangyang","Yezzi, Anthony J."],"year":2013,"date_issued":"2013-08-02","date_published":"2013-08-02","updated_at":"2026-11-19T06:00:01Z","subjects":["Magnetic resonance imaging","Cardiac resynchronization therapy","Electrophysiology","Image processing","Heart failure","Heart Magnetic resonance imaging","Cardiac pacing","Electric stimulation","Congestive heart failure Treatment"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1853/50224","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1853/50224","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F50224","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Oshinski, John N."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Brummer, Marijn E.","Lloyd, Michael S.","Sechopoulos, Ioannis","Tang, Xiangyang","Yezzi, Anthony J."]},{"key":"dc:contributor.department","label":"Department","values":["Biomedical Engineering (Joint GT/Emory Department)"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Wallace H. Coulter Department of Biomedical Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Suever, Jonathan D."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-01-13T16:19:42Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-01-13T16:19:42Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2013-12"]},{"key":"dc:date.issued","label":"Date","values":["2013-08-02"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["December 2013"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2014-01-13T16:19:42Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["05472fe1-6d57-4489-af83-42115a3f55cc"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Doctor of Philosophy with a Major in Biomedical Engineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["da59be3c-3d0a-41da-91b9-ebe2ecc83b66","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["d85f9f1b-b2b5-4bca-81af-4515c5281e54"]},{"key":"dc:type","label":"Dc Type","values":["Text","Dissertation"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctoral"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Magnetic resonance imaging","Cardiac resynchronization therapy","Electrophysiology","Image processing"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Heart failure","Heart Magnetic resonance imaging","Cardiac pacing","Electric stimulation","Congestive heart failure Treatment"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/50224"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Cardiac Resynchronization Therapy (CRT) is a treatment option for heart failure patients with ventricular dyssynchrony. CRT corrects for dyssynchrony by electrically stimulating the septal and lateral walls of the left ventricle (LV), forcing synchronous con- traction and improving cardiac output. Current selection criteria for CRT rely upon the QRS duration, measured from a surface electrocardiogram, as a marker of electrical dyssynchrony. Unfortunately, 30-40% of patients undergoing CRT fail to benefit from the treatment. A multitude of studies have shown that presence of mechanical dyssynchrony in the LV is an important factor in determining if a patient will benefit from CRT. Furthermore, recent evidence suggests that patient response can be improved by placing the LV pacing lead in the most dyssynchronous or latest contracting segment. The overall goal of this project was to develop methods that allow for accurate assessment and display of regional mechanical dyssynchrony throughout the LV and at the site of the LV pacing lead. To accomplish this goal, we developed a method for quantifying regional dyssynchrony from standard short-axis cine magnetic resonance (MR) images. To assess the effects of LV lead placement, we developed a registration method that allows us to project the LV lead location from dual-plane fluoroscopy onto MR measurements of cardiac function. By applying these techniques in patients undergoing CRT, we were able to investigate the relationship between regional dyssynchrony, LV pacing lead location, and CRT response."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph.D."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["MRI methods for predicting response to cardiac resynchronization therapy"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Oshinski, John N."],"dc:contributor.committeemember":["Brummer, Marijn E.","Lloyd, Michael S.","Sechopoulos, Ioannis","Tang, Xiangyang","Yezzi, Anthony J."],"dc:contributor.department":["Biomedical Engineering (Joint GT/Emory Department)"],"dc:contributor.other":["Wallace H. Coulter Department of Biomedical Engineering","College of Engineering"],"dc:creator":["Suever, Jonathan D."],"dc:date.accessioned":["2014-01-13T16:19:42Z"],"dc:date.available":["2014-01-13T16:19:42Z"],"dc:date.created":["2013-12"],"dc:date.issued":["2013-08-02"],"dc:date.submitted":["December 2013"],"dc:date.updated":["2014-01-13T16:19:42Z"],"dc:description.abstract":["Cardiac Resynchronization Therapy (CRT) is a treatment option for heart failure patients with ventricular dyssynchrony. CRT corrects for dyssynchrony by electrically stimulating the septal and lateral walls of the left ventricle (LV), forcing synchronous con- traction and improving cardiac output. Current selection criteria for CRT rely upon the QRS duration, measured from a surface electrocardiogram, as a marker of electrical dyssynchrony. Unfortunately, 30-40% of patients undergoing CRT fail to benefit from the treatment. A multitude of studies have shown that presence of mechanical dyssynchrony in the LV is an important factor in determining if a patient will benefit from CRT. Furthermore, recent evidence suggests that patient response can be improved by placing the LV pacing lead in the most dyssynchronous or latest contracting segment. The overall goal of this project was to develop methods that allow for accurate assessment and display of regional mechanical dyssynchrony throughout the LV and at the site of the LV pacing lead. To accomplish this goal, we developed a method for quantifying regional dyssynchrony from standard short-axis cine magnetic resonance (MR) images. To assess the effects of LV lead placement, we developed a registration method that allows us to project the LV lead location from dual-plane fluoroscopy onto MR measurements of cardiac function. By applying these techniques in patients undergoing CRT, we were able to investigate the relationship between regional dyssynchrony, LV pacing lead location, and CRT response."],"dc:description.degree":["Ph.D."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1853/50224"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["05472fe1-6d57-4489-af83-42115a3f55cc"],"dc:relation.ispartofseries":["Doctor of Philosophy with a Major in Biomedical Engineering"],"dc:relation.orgunit":["da59be3c-3d0a-41da-91b9-ebe2ecc83b66","7c022d60-21d5-497c-b552-95e489a06569"],"dc:relation.seriesentity":["d85f9f1b-b2b5-4bca-81af-4515c5281e54"],"dc:subject":["Magnetic resonance imaging","Cardiac resynchronization therapy","Electrophysiology","Image processing"],"dc:subject.lcsh":["Heart failure","Heart Magnetic resonance imaging","Cardiac pacing","Electric stimulation","Congestive heart failure Treatment"],"dc:title":["MRI methods for predicting response to cardiac resynchronization therapy"],"dc:type":["Text","Dissertation"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Doctoral"]},"updated_at":"2026-11-19T06:00:01Z"}