{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/50335"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/50335","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Single-shot measurements of complex pulses using frequency-resolved optical gating","abstract":"Frequency-resolved optical gating (FROG) is the standard for measuring femtosecond laser pulses. It measures relatively simple pulses on a single-shot and complex pulses using multi-shot scanning and averaging. However, experience from intensity autocorrelation suggests that multi-shot measurements may suffer from a coherent artifact caused by instability in the laser source. In this thesis, the coherent artifacts present in modern pulse measurement techniques are examined and single-shot techniques for measuring complex pulse(s) are proposed and demonstrated. The study of the coherent artifact in this work shows that modern pulse measurement techniques also suffer from coherent artifacts and therefore single-shot measurements should be performed when possible. Here, two single-shot experimental setups are developed for different scenarios. First, an extension of FROG is developed to measure two unknown pulses simultaneously on a single-shot. This setup can measure pulses that have very different center wavelengths, spectral bandwidths, and complexities. Second, pulse-front tilt is incorporated to extend the temporal range of single-shot FROG to tens of picoseconds which traditionally can only be attained by multi-shot scanning. Finally, the pulse-front tilt setup is modified to perform a single-shot measurement of supercontinuum, one of the most difficult pulses to measure due to its long temporal range, broad spectral bandwidth, and low pulse energy.","abstract_html":"Frequency-resolved optical gating (FROG) is the standard for measuring femtosecond laser pulses. It measures relatively simple pulses on a single-shot and complex pulses using multi-shot scanning and averaging. However, experience from intensity autocorrelation suggests that multi-shot measurements may suffer from a coherent artifact caused by instability in the laser source. In this thesis, the coherent artifacts present in modern pulse measurement techniques are examined and single-shot techniques for measuring complex pulse(s) are proposed and demonstrated. The study of the coherent artifact in this work shows that modern pulse measurement techniques also suffer from coherent artifacts and therefore single-shot measurements should be performed when possible. Here, two single-shot experimental setups are developed for different scenarios. First, an extension of FROG is developed to measure two unknown pulses simultaneously on a single-shot. This setup can measure pulses that have very different center wavelengths, spectral bandwidths, and complexities. Second, pulse-front tilt is incorporated to extend the temporal range of single-shot FROG to tens of picoseconds which traditionally can only be attained by multi-shot scanning. Finally, the pulse-front tilt setup is modified to perform a single-shot measurement of supercontinuum, one of the most difficult pulses to measure due to its long temporal range, broad spectral bandwidth, and low pulse energy.","abstract_has_math":false,"creators":["Wong, Tsz Chun"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Doctoral","degree_discipline":null,"degree_department":"Physics","school":null,"contributors":[],"advisors":["Trebino, Rick"],"committee_chairs":[],"committee_members":["Curtis, Jennifer","Jiang, Zhigang","Buck, John","Adibi, Ali"],"year":2013,"date_issued":"2013-11-07","date_published":"2013-11-07","updated_at":"2026-11-19T04:51:38Z","subjects":["Ultrafast optics","Ultrafast measurement","Laser pulses, Ultrashort Measurement"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/50335","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/50335","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F50335","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Trebino, Rick"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Curtis, Jennifer","Jiang, Zhigang","Buck, John","Adibi, Ali"]},{"key":"dc:contributor.department","label":"Department","values":["Physics"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["College of Sciences","School of Physics"]},{"key":"dc:creator","label":"Author","values":["Wong, Tsz Chun"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-01-13T16:48:46Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-01-13T16:48:46Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2013-12"]},{"key":"dc:date.issued","label":"Date","values":["2013-11-07"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["December 2013"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2014-01-13T16:48:46Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["40e4f324-6c45-4fe1-ac68-68c3ea37970f"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Doctor of Philosophy with a Major in Physics"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["85042be6-2d68-4e07-b384-e1f908fae48a","2ba39017-11f1-40f4-9bc5-66f17b8f1539"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["c1062152-d026-4fb3-84db-ceedbfbbbf56"]},{"key":"dc:type","label":"Dc Type","values":["Text","Dissertation"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctoral"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Ultrafast optics","Ultrafast measurement"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Laser pulses, Ultrashort Measurement"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/50335"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Frequency-resolved optical gating (FROG) is the standard for measuring femtosecond laser pulses. It measures relatively simple pulses on a single-shot and complex pulses using multi-shot scanning and averaging. However, experience from intensity autocorrelation suggests that multi-shot measurements may suffer from a coherent artifact caused by instability in the laser source. In this thesis, the coherent artifacts present in modern pulse measurement techniques are examined and single-shot techniques for measuring complex pulse(s) are proposed and demonstrated. The study of the coherent artifact in this work shows that modern pulse measurement techniques also suffer from coherent artifacts and therefore single-shot measurements should be performed when possible. Here, two single-shot experimental setups are developed for different scenarios. First, an extension of FROG is developed to measure two unknown pulses simultaneously on a single-shot. This setup can measure pulses that have very different center wavelengths, spectral bandwidths, and complexities. Second, pulse-front tilt is incorporated to extend the temporal range of single-shot FROG to tens of picoseconds which traditionally can only be attained by multi-shot scanning. Finally, the pulse-front tilt setup is modified to perform a single-shot measurement of supercontinuum, one of the most difficult pulses to measure due to its long temporal range, broad spectral bandwidth, and low pulse energy."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph.D."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Single-shot measurements of complex pulses using frequency-resolved optical gating"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Trebino, Rick"],"dc:contributor.committeemember":["Curtis, Jennifer","Jiang, Zhigang","Buck, John","Adibi, Ali"],"dc:contributor.department":["Physics"],"dc:contributor.other":["College of Sciences","School of Physics"],"dc:creator":["Wong, Tsz Chun"],"dc:date.accessioned":["2014-01-13T16:48:46Z"],"dc:date.available":["2014-01-13T16:48:46Z"],"dc:date.created":["2013-12"],"dc:date.issued":["2013-11-07"],"dc:date.submitted":["December 2013"],"dc:date.updated":["2014-01-13T16:48:46Z"],"dc:description.abstract":["Frequency-resolved optical gating (FROG) is the standard for measuring femtosecond laser pulses. It measures relatively simple pulses on a single-shot and complex pulses using multi-shot scanning and averaging. However, experience from intensity autocorrelation suggests that multi-shot measurements may suffer from a coherent artifact caused by instability in the laser source. In this thesis, the coherent artifacts present in modern pulse measurement techniques are examined and single-shot techniques for measuring complex pulse(s) are proposed and demonstrated. The study of the coherent artifact in this work shows that modern pulse measurement techniques also suffer from coherent artifacts and therefore single-shot measurements should be performed when possible. Here, two single-shot experimental setups are developed for different scenarios. First, an extension of FROG is developed to measure two unknown pulses simultaneously on a single-shot. This setup can measure pulses that have very different center wavelengths, spectral bandwidths, and complexities. Second, pulse-front tilt is incorporated to extend the temporal range of single-shot FROG to tens of picoseconds which traditionally can only be attained by multi-shot scanning. Finally, the pulse-front tilt setup is modified to perform a single-shot measurement of supercontinuum, one of the most difficult pulses to measure due to its long temporal range, broad spectral bandwidth, and low pulse energy."],"dc:description.degree":["Ph.D."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1853/50335"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["40e4f324-6c45-4fe1-ac68-68c3ea37970f"],"dc:relation.ispartofseries":["Doctor of Philosophy with a Major in Physics"],"dc:relation.orgunit":["85042be6-2d68-4e07-b384-e1f908fae48a","2ba39017-11f1-40f4-9bc5-66f17b8f1539"],"dc:relation.seriesentity":["c1062152-d026-4fb3-84db-ceedbfbbbf56"],"dc:subject":["Ultrafast optics","Ultrafast measurement"],"dc:subject.lcsh":["Laser pulses, Ultrashort Measurement"],"dc:title":["Single-shot measurements of complex pulses using frequency-resolved optical gating"],"dc:type":["Text","Dissertation"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Doctoral"]},"updated_at":"2026-11-19T04:51:38Z"}