{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/5044"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/5044","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Miniaturized Diffraction Based Interferometric Distance Measurement Sensor","abstract":"In this thesis, new metrology hardware is designed, fabricated, and tested to provide improvements over current MEMS metrology. The metrology system is a micromachined scanning interferometer having a sub-nm resolution in a compact design. The proposed microinterferometer forms a phase sensitive diffraction grating with interferometric sensitivity, while adding the capability of better lateral resolution by focusing the laser to a smaller spot size. A detailed diffraction model of the microinterferometer was developed to simulate the device performance and to suggest the location of photo detectors for integrated optoelectronics. A particular device is fabricated on a fused silica substrate using aluminum to form the deformable diffraction grating fingers and AZ P4620 photo resist (PR) for the microlens. The details of the fabrication processes are presented. The structure also enables optoelectronics to be integrated so that the interferometer with photo detectors can fit in an area that is 1mm x 1mm. The scanning results using a fixed grating micromachined scanning interferometer demonstrated that it could measure vibration profile as well as static vertical(less than a half wave length) and lateral dimension of MEMS. The SI, which is integrated with photo diodes, demonstrated its operation by scanning a cMUT. The PID control has been tested and resulted in improvement in scanned images. The integrated micromachined scanning interferometer demonstrated that the deformable grating could be used to tune the measurement keep the interferometer in quadrature for highest sensitivity.","abstract_html":"In this thesis, new metrology hardware is designed, fabricated, and tested to provide improvements over current MEMS metrology. The metrology system is a micromachined scanning interferometer having a sub-nm resolution in a compact design. The proposed microinterferometer forms a phase sensitive diffraction grating with interferometric sensitivity, while adding the capability of better lateral resolution by focusing the laser to a smaller spot size. A detailed diffraction model of the microinterferometer was developed to simulate the device performance and to suggest the location of photo detectors for integrated optoelectronics. A particular device is fabricated on a fused silica substrate using aluminum to form the deformable diffraction grating fingers and AZ P4620 photo resist (PR) for the microlens. The details of the fabrication processes are presented. The structure also enables optoelectronics to be integrated so that the interferometer with photo detectors can fit in an area that is 1mm x 1mm. The scanning results using a fixed grating micromachined scanning interferometer demonstrated that it could measure vibration profile as well as static vertical(less than a half wave length) and lateral dimension of MEMS. The SI, which is integrated with photo diodes, demonstrated its operation by scanning a cMUT. The PID control has been tested and resulted in improvement in scanned images. The integrated micromachined scanning interferometer demonstrated that the deformable grating could be used to tune the measurement keep the interferometer in quadrature for highest sensitivity.","abstract_has_math":false,"creators":["Kim, Byungki"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["Kurfess, Thomas R.","Degertekin, F. Levent"],"committee_chairs":[],"committee_members":["Ayazi, Farrokh","Gaylord, Thomas","Hesketh, Peter"],"year":2004,"date_issued":"2004-07-09","date_published":"2004-07-09","updated_at":"2026-11-19T06:05:50Z","subjects":["Scanning","MEMS","Interferometers","Metrology"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/5044","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/5044","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F5044","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Kurfess, Thomas R.","Degertekin, F. Levent"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Ayazi, Farrokh","Gaylord, Thomas","Hesketh, Peter"]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["George W. Woodruff School of Mechanical Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Kim, Byungki"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2005-03-02T22:22:13Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2005-03-02T22:22:13Z"]},{"key":"dc:date.issued","label":"Date","values":["2004-07-09"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["1fae7587-6ed2-4214-b785-8741ad9f465a","9afd92fe-bb98-4c83-b8ac-fc596320991a"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Doctor of Philosophy with a Major in Mechanical Engineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["c01ff908-c25f-439b-bf10-a074ed886bb7","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["a27a5c68-ea1b-411c-8430-0e28936f53d2"]},{"key":"dc:type","label":"Dc Type","values":["Text","Dissertation"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Scanning","MEMS","Interferometers","Metrology"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/5044"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["In this thesis, new metrology hardware is designed, fabricated, and tested to provide improvements over current MEMS metrology. The metrology system is a micromachined scanning interferometer having a sub-nm resolution in a compact design. The proposed microinterferometer forms a phase sensitive diffraction grating with interferometric sensitivity, while adding the capability of better lateral resolution by focusing the laser to a smaller spot size. A detailed diffraction model of the microinterferometer was developed to simulate the device performance and to suggest the location of photo detectors for integrated optoelectronics. A particular device is fabricated on a fused silica substrate using aluminum to form the deformable diffraction grating fingers and AZ P4620 photo resist (PR) for the microlens. The details of the fabrication processes are presented. The structure also enables optoelectronics to be integrated so that the interferometer with photo detectors can fit in an area that is 1mm x 1mm. The scanning results using a fixed grating micromachined scanning interferometer demonstrated that it could measure vibration profile as well as static vertical(less than a half wave length) and lateral dimension of MEMS. The SI, which is integrated with photo diodes, demonstrated its operation by scanning a cMUT. The PID control has been tested and resulted in improvement in scanned images. The integrated micromachined scanning interferometer demonstrated that the deformable grating could be used to tune the measurement keep the interferometer in quadrature for highest sensitivity."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph.D."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["4961111 bytes"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Miniaturized Diffraction Based Interferometric Distance Measurement Sensor"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Kurfess, Thomas R.","Degertekin, F. Levent"],"dc:contributor.committeemember":["Ayazi, Farrokh","Gaylord, Thomas","Hesketh, Peter"],"dc:contributor.department":["Mechanical Engineering"],"dc:contributor.other":["George W. Woodruff School of Mechanical Engineering","College of Engineering"],"dc:creator":["Kim, Byungki"],"dc:date.accessioned":["2005-03-02T22:22:13Z"],"dc:date.available":["2005-03-02T22:22:13Z"],"dc:date.issued":["2004-07-09"],"dc:description.abstract":["In this thesis, new metrology hardware is designed, fabricated, and tested to provide improvements over current MEMS metrology. The metrology system is a micromachined scanning interferometer having a sub-nm resolution in a compact design. The proposed microinterferometer forms a phase sensitive diffraction grating with interferometric sensitivity, while adding the capability of better lateral resolution by focusing the laser to a smaller spot size. A detailed diffraction model of the microinterferometer was developed to simulate the device performance and to suggest the location of photo detectors for integrated optoelectronics. A particular device is fabricated on a fused silica substrate using aluminum to form the deformable diffraction grating fingers and AZ P4620 photo resist (PR) for the microlens. The details of the fabrication processes are presented. The structure also enables optoelectronics to be integrated so that the interferometer with photo detectors can fit in an area that is 1mm x 1mm. The scanning results using a fixed grating micromachined scanning interferometer demonstrated that it could measure vibration profile as well as static vertical(less than a half wave length) and lateral dimension of MEMS. The SI, which is integrated with photo diodes, demonstrated its operation by scanning a cMUT. The PID control has been tested and resulted in improvement in scanned images. The integrated micromachined scanning interferometer demonstrated that the deformable grating could be used to tune the measurement keep the interferometer in quadrature for highest sensitivity."],"dc:description.degree":["Ph.D."],"dc:format.extent":["4961111 bytes"],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1853/5044"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["1fae7587-6ed2-4214-b785-8741ad9f465a","9afd92fe-bb98-4c83-b8ac-fc596320991a"],"dc:relation.ispartofseries":["Doctor of Philosophy with a Major in Mechanical Engineering"],"dc:relation.orgunit":["c01ff908-c25f-439b-bf10-a074ed886bb7","7c022d60-21d5-497c-b552-95e489a06569"],"dc:relation.seriesentity":["a27a5c68-ea1b-411c-8430-0e28936f53d2"],"dc:subject":["Scanning","MEMS","Interferometers","Metrology"],"dc:title":["Miniaturized Diffraction Based Interferometric Distance Measurement Sensor"],"dc:type":["Text","Dissertation"],"dspace:entity.type":["Publication"]},"updated_at":"2026-11-19T06:05:50Z"}