{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/51778"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/51778","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Effect of elevated temperature on ceramic ultrafiltration of colloidal suspensions","abstract":"The inherent thermal resistance of ceramic membranes allows for treatment of industrial waters at elevated temperatures. Traditionally, the high temperature of wastewater has been an issue compromising the integrity of polymeric membrane systems or requiring the temperature to be lowered for further treatments. In ceramic membrane systems, a decrease in viscosity with increasing temperature, however, can be utilized, which increases the permeate flux. In this study, the fouling of ceramic ultrafiltration by feed solutions containing colloidal silica was evaluated at temperatures between 25 – 90 °C seen in various industries. Ceramic membranes were able to perform well at elevated temperatures up to 90 ºC with sustained mechanical and chemical integrity. Results showed net benefit of filtration at elevated temperatures on permeate flux in spite of increasing total fouling resistance with temperature. When the temperature increased from 25 to 90 °C, there was a 90% increase in steady-state permeate flux. The dominant resistance was physically removable fouling, and the increase in fouling with feed temperature was supported by force balance analyses. This study provides a foundation from which further studies can be developed including pilot-scale testing, use of real wastewater, and the effects of operating conditions.","abstract_html":"The inherent thermal resistance of ceramic membranes allows for treatment of industrial waters at elevated temperatures. Traditionally, the high temperature of wastewater has been an issue compromising the integrity of polymeric membrane systems or requiring the temperature to be lowered for further treatments. In ceramic membrane systems, a decrease in viscosity with increasing temperature, however, can be utilized, which increases the permeate flux. In this study, the fouling of ceramic ultrafiltration by feed solutions containing colloidal silica was evaluated at temperatures between 25 – 90 °C seen in various industries. Ceramic membranes were able to perform well at elevated temperatures up to 90 ºC with sustained mechanical and chemical integrity. Results showed net benefit of filtration at elevated temperatures on permeate flux in spite of increasing total fouling resistance with temperature. When the temperature increased from 25 to 90 °C, there was a 90% increase in steady-state permeate flux. The dominant resistance was physically removable fouling, and the increase in fouling with feed temperature was supported by force balance analyses. This study provides a foundation from which further studies can be developed including pilot-scale testing, use of real wastewater, and the effects of operating conditions.","abstract_has_math":false,"creators":["Cromey, Tyler"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Masters","degree_discipline":null,"degree_department":"Civil and Environmental Engineering","school":null,"contributors":[],"advisors":["Kim, Jae-Hong"],"committee_chairs":[],"committee_members":["Huang, Ching-Hua","Koon, John H."],"year":2014,"date_issued":"2014-04-09","date_published":"2014-04-09","updated_at":"2026-11-19T05:12:01Z","subjects":["Ceramic membrane","Wastewater","Colloidal silica","Resistance in series","Flux decline","Temperature effect","Filtration","Force balance","Ultrafiltration","Suspensions (Chemistry)","Ceramic materials","Membranes (Technology)","Water Purification","Sewage Purification"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/51778","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/51778","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F51778","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Kim, Jae-Hong"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Huang, Ching-Hua","Koon, John H."]},{"key":"dc:contributor.department","label":"Department","values":["Civil and Environmental Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["School of Civil and Environmental Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Cromey, Tyler"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-05-22T15:20:34Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-05-22T15:20:34Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2014-05"]},{"key":"dc:date.issued","label":"Date","values":["2014-04-09"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["May 2014"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2014-05-22T15:20:34Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["88639fad-d3ae-4867-9e7a-7c9e6d2ecc7c","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:type","label":"Dc Type","values":["Text","Thesis"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Ceramic membrane","Wastewater","Colloidal silica","Resistance in series","Flux decline","Temperature effect","Filtration","Force balance"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Ultrafiltration","Suspensions (Chemistry)","Ceramic materials","Membranes (Technology)","Water Purification","Sewage Purification"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/51778"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The inherent thermal resistance of ceramic membranes allows for treatment of industrial waters at elevated temperatures. Traditionally, the high temperature of wastewater has been an issue compromising the integrity of polymeric membrane systems or requiring the temperature to be lowered for further treatments. In ceramic membrane systems, a decrease in viscosity with increasing temperature, however, can be utilized, which increases the permeate flux. In this study, the fouling of ceramic ultrafiltration by feed solutions containing colloidal silica was evaluated at temperatures between 25 – 90 °C seen in various industries. Ceramic membranes were able to perform well at elevated temperatures up to 90 ºC with sustained mechanical and chemical integrity. Results showed net benefit of filtration at elevated temperatures on permeate flux in spite of increasing total fouling resistance with temperature. When the temperature increased from 25 to 90 °C, there was a 90% increase in steady-state permeate flux. The dominant resistance was physically removable fouling, and the increase in fouling with feed temperature was supported by force balance analyses. This study provides a foundation from which further studies can be developed including pilot-scale testing, use of real wastewater, and the effects of operating conditions."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.S."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Effect of elevated temperature on ceramic ultrafiltration of colloidal suspensions"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Kim, Jae-Hong"],"dc:contributor.committeemember":["Huang, Ching-Hua","Koon, John H."],"dc:contributor.department":["Civil and Environmental Engineering"],"dc:contributor.other":["School of Civil and Environmental Engineering","College of Engineering"],"dc:creator":["Cromey, Tyler"],"dc:date.accessioned":["2014-05-22T15:20:34Z"],"dc:date.available":["2014-05-22T15:20:34Z"],"dc:date.created":["2014-05"],"dc:date.issued":["2014-04-09"],"dc:date.submitted":["May 2014"],"dc:date.updated":["2014-05-22T15:20:34Z"],"dc:description.abstract":["The inherent thermal resistance of ceramic membranes allows for treatment of industrial waters at elevated temperatures. Traditionally, the high temperature of wastewater has been an issue compromising the integrity of polymeric membrane systems or requiring the temperature to be lowered for further treatments. In ceramic membrane systems, a decrease in viscosity with increasing temperature, however, can be utilized, which increases the permeate flux. In this study, the fouling of ceramic ultrafiltration by feed solutions containing colloidal silica was evaluated at temperatures between 25 – 90 °C seen in various industries. Ceramic membranes were able to perform well at elevated temperatures up to 90 ºC with sustained mechanical and chemical integrity. Results showed net benefit of filtration at elevated temperatures on permeate flux in spite of increasing total fouling resistance with temperature. When the temperature increased from 25 to 90 °C, there was a 90% increase in steady-state permeate flux. The dominant resistance was physically removable fouling, and the increase in fouling with feed temperature was supported by force balance analyses. This study provides a foundation from which further studies can be developed including pilot-scale testing, use of real wastewater, and the effects of operating conditions."],"dc:description.degree":["M.S."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1853/51778"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.orgunit":["88639fad-d3ae-4867-9e7a-7c9e6d2ecc7c","7c022d60-21d5-497c-b552-95e489a06569"],"dc:subject":["Ceramic membrane","Wastewater","Colloidal silica","Resistance in series","Flux decline","Temperature effect","Filtration","Force balance"],"dc:subject.lcsh":["Ultrafiltration","Suspensions (Chemistry)","Ceramic materials","Membranes (Technology)","Water Purification","Sewage Purification"],"dc:title":["Effect of elevated temperature on ceramic ultrafiltration of colloidal suspensions"],"dc:type":["Text","Thesis"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Masters"]},"updated_at":"2026-11-19T05:12:01Z"}