{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/51879"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/51879","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Assessment of repetitive facilitation exercise with fMRI-compatible rehabilitation device for hemiparetic limbs","abstract":"In order for stroke subjects to gain functional recovery of their hemiparetic limbs, facilitation techniques such as the repetitive facilitation exercise, or RFE, have been developed. Currently, there is a lack of understanding of the neural mechanisms associated with these types of facilitation techniques. To better understand the neural mechanisms associated with the RFE a functional magnetic resonance imaging (fMRI) study should be conducted. This thesis presents experimental results testing the feasibility of implementing an fMRI-compatible actuator to facilitate a myotatic reflex in synchronization with the subject’s intention to move their hemiparetic limb. Preliminary data from a healthy individual demonstrated the feasibility of overlapping the long latency component of the afferent myotatic reflex, created by electrical stimulation, with descending nerve impulses, created using transcranial magnetic stimulation, in a time window of 15ms. In addition, a pneumatic actuation time delay due to long transmission line was evaluated. The pneumatic actuator met the timing precision requirement for the rehabilitation device for varying transmission line lengths. Therefore a pneumatic actuation system was chosen for the rehabilitation device. This thesis will also presents on the design of an fMRI-compatible pneumatic actuator device to excite a stretch reflex response. Initial, experimental results with the device demonstrated that the designed pneumatic device can control the timing of the muscle response with a fixed signal within the required 15ms window required for cortical facilitation, which was found in the previous feasibility study. However, the device was unable to create a long latency reflex observable at the muscle. Finally, this thesis presents on the capability of the device in creating subthreshold long latency response with precision to overlap with a subthreshold descending nerve impulse, created using transcranial magnetic stimulation. The overlap of the two responses was evaluated by comparing the amplitude of the muscle response with and without the stretch reflex, created by the fMRI-compatible pneumatic actuator device. Varying time delays were analyzed.","abstract_html":"In order for stroke subjects to gain functional recovery of their hemiparetic limbs, facilitation techniques such as the repetitive facilitation exercise, or RFE, have been developed. Currently, there is a lack of understanding of the neural mechanisms associated with these types of facilitation techniques. To better understand the neural mechanisms associated with the RFE a functional magnetic resonance imaging (fMRI) study should be conducted. This thesis presents experimental results testing the feasibility of implementing an fMRI-compatible actuator to facilitate a myotatic reflex in synchronization with the subject’s intention to move their hemiparetic limb. Preliminary data from a healthy individual demonstrated the feasibility of overlapping the long latency component of the afferent myotatic reflex, created by electrical stimulation, with descending nerve impulses, created using transcranial magnetic stimulation, in a time window of 15ms. In addition, a pneumatic actuation time delay due to long transmission line was evaluated. The pneumatic actuator met the timing precision requirement for the rehabilitation device for varying transmission line lengths. Therefore a pneumatic actuation system was chosen for the rehabilitation device. This thesis will also presents on the design of an fMRI-compatible pneumatic actuator device to excite a stretch reflex response. Initial, experimental results with the device demonstrated that the designed pneumatic device can control the timing of the muscle response with a fixed signal within the required 15ms window required for cortical facilitation, which was found in the previous feasibility study. However, the device was unable to create a long latency reflex observable at the muscle. Finally, this thesis presents on the capability of the device in creating subthreshold long latency response with precision to overlap with a subthreshold descending nerve impulse, created using transcranial magnetic stimulation. The overlap of the two responses was evaluated by comparing the amplitude of the muscle response with and without the stretch reflex, created by the fMRI-compatible pneumatic actuator device. Varying time delays were analyzed.","abstract_has_math":false,"creators":["Lacey, Lauren Elizabeth"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Masters","degree_discipline":null,"degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["Ueda, Jun"],"committee_chairs":[],"committee_members":["Book, Wayne","Shinohara, Minoru"],"year":2014,"date_issued":"2014-04-03","date_published":"2014-04-03","updated_at":"2026-11-19T05:06:19Z","subjects":["Stroke","Rehabilitation device","fMRI-compatible","Long latency reflex","Hemiparetic","Stretch reflex","Pneumatics","Medical rehabilitation","Magnetic resonance imaging","Actuators","Pneumatic control"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/51879","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/51879","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F51879","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Ueda, Jun"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Book, Wayne","Shinohara, Minoru"]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["George W. Woodruff School of Mechanical Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Lacey, Lauren Elizabeth"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-05-22T15:32:05Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-05-22T15:32:05Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2014-05"]},{"key":"dc:date.issued","label":"Date","values":["2014-04-03"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["May 2014"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2014-05-22T15:32:05Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["7ff601c5-b262-4830-8a06-b75c55f5f1c8"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["c01ff908-c25f-439b-bf10-a074ed886bb7","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:type","label":"Dc Type","values":["Text","Thesis"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Stroke","Rehabilitation device","fMRI-compatible","Long latency reflex","Hemiparetic","Stretch reflex","Pneumatics"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Medical rehabilitation","Magnetic resonance imaging","Actuators","Pneumatic control"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/51879"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["In order for stroke subjects to gain functional recovery of their hemiparetic limbs, facilitation techniques such as the repetitive facilitation exercise, or RFE, have been developed. Currently, there is a lack of understanding of the neural mechanisms associated with these types of facilitation techniques. To better understand the neural mechanisms associated with the RFE a functional magnetic resonance imaging (fMRI) study should be conducted. This thesis presents experimental results testing the feasibility of implementing an fMRI-compatible actuator to facilitate a myotatic reflex in synchronization with the subject’s intention to move their hemiparetic limb. Preliminary data from a healthy individual demonstrated the feasibility of overlapping the long latency component of the afferent myotatic reflex, created by electrical stimulation, with descending nerve impulses, created using transcranial magnetic stimulation, in a time window of 15ms. In addition, a pneumatic actuation time delay due to long transmission line was evaluated. The pneumatic actuator met the timing precision requirement for the rehabilitation device for varying transmission line lengths. Therefore a pneumatic actuation system was chosen for the rehabilitation device. This thesis will also presents on the design of an fMRI-compatible pneumatic actuator device to excite a stretch reflex response. Initial, experimental results with the device demonstrated that the designed pneumatic device can control the timing of the muscle response with a fixed signal within the required 15ms window required for cortical facilitation, which was found in the previous feasibility study. However, the device was unable to create a long latency reflex observable at the muscle. Finally, this thesis presents on the capability of the device in creating subthreshold long latency response with precision to overlap with a subthreshold descending nerve impulse, created using transcranial magnetic stimulation. The overlap of the two responses was evaluated by comparing the amplitude of the muscle response with and without the stretch reflex, created by the fMRI-compatible pneumatic actuator device. Varying time delays were analyzed."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.S."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Assessment of repetitive facilitation exercise with fMRI-compatible rehabilitation device for hemiparetic limbs"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Ueda, Jun"],"dc:contributor.committeemember":["Book, Wayne","Shinohara, Minoru"],"dc:contributor.department":["Mechanical Engineering"],"dc:contributor.other":["George W. Woodruff School of Mechanical Engineering","College of Engineering"],"dc:creator":["Lacey, Lauren Elizabeth"],"dc:date.accessioned":["2014-05-22T15:32:05Z"],"dc:date.available":["2014-05-22T15:32:05Z"],"dc:date.created":["2014-05"],"dc:date.issued":["2014-04-03"],"dc:date.submitted":["May 2014"],"dc:date.updated":["2014-05-22T15:32:05Z"],"dc:description.abstract":["In order for stroke subjects to gain functional recovery of their hemiparetic limbs, facilitation techniques such as the repetitive facilitation exercise, or RFE, have been developed. Currently, there is a lack of understanding of the neural mechanisms associated with these types of facilitation techniques. To better understand the neural mechanisms associated with the RFE a functional magnetic resonance imaging (fMRI) study should be conducted. This thesis presents experimental results testing the feasibility of implementing an fMRI-compatible actuator to facilitate a myotatic reflex in synchronization with the subject’s intention to move their hemiparetic limb. Preliminary data from a healthy individual demonstrated the feasibility of overlapping the long latency component of the afferent myotatic reflex, created by electrical stimulation, with descending nerve impulses, created using transcranial magnetic stimulation, in a time window of 15ms. In addition, a pneumatic actuation time delay due to long transmission line was evaluated. The pneumatic actuator met the timing precision requirement for the rehabilitation device for varying transmission line lengths. Therefore a pneumatic actuation system was chosen for the rehabilitation device. This thesis will also presents on the design of an fMRI-compatible pneumatic actuator device to excite a stretch reflex response. Initial, experimental results with the device demonstrated that the designed pneumatic device can control the timing of the muscle response with a fixed signal within the required 15ms window required for cortical facilitation, which was found in the previous feasibility study. However, the device was unable to create a long latency reflex observable at the muscle. Finally, this thesis presents on the capability of the device in creating subthreshold long latency response with precision to overlap with a subthreshold descending nerve impulse, created using transcranial magnetic stimulation. The overlap of the two responses was evaluated by comparing the amplitude of the muscle response with and without the stretch reflex, created by the fMRI-compatible pneumatic actuator device. Varying time delays were analyzed."],"dc:description.degree":["M.S."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1853/51879"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["7ff601c5-b262-4830-8a06-b75c55f5f1c8"],"dc:relation.orgunit":["c01ff908-c25f-439b-bf10-a074ed886bb7","7c022d60-21d5-497c-b552-95e489a06569"],"dc:subject":["Stroke","Rehabilitation device","fMRI-compatible","Long latency reflex","Hemiparetic","Stretch reflex","Pneumatics"],"dc:subject.lcsh":["Medical rehabilitation","Magnetic resonance imaging","Actuators","Pneumatic control"],"dc:title":["Assessment of repetitive facilitation exercise with fMRI-compatible rehabilitation device for hemiparetic limbs"],"dc:type":["Text","Thesis"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Masters"]},"updated_at":"2026-11-19T05:06:19Z"}