{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/5188"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/5188","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Active Flow Control of Lab-Scale Solid Polymer Electrolyte Fuel Cells","abstract":"The effects of actively pulsing reactant flow rates into solid polymer electrolyte fuel cells were investigated in this thesis. First, work was conducted to determine the magnitude of voltage response to pulsed reactant flow on a direct hydrogen proton exchange membrane (PEM) cell. The effects of pulsed reactant flow into a direct methanol fuel cell (DMFC) were then considered. The PEM work showed substantially greater response to pulsed air flow than to pulsed fuel flow. It was found that several parameters affect the magnitude of cell response to active flow control (AFC). Increasing current load, increasing the magnitude of flow oscillation, decreasing the frequency of oscillation, and decreasing the average level of excess reactant supplied were found to maximize both the level of voltage oscillations and the decrease in cell power from steady state performance. Greater response to pulsed oxidant flow is believed to have been observed due to effects brought about by changes in membrane humidity. In contrast, pulsed fuel flow showed the greatest response in the study of DMFC technology. In this case, time averaged cell voltage was found to increase as the time averaged fuel flow rate was reduced. The increase in average cell power is the result of a reduction in methanol crossover; sustainable increases of up to 6% in power output were measured. The parameters found to effect the increase in cell power observed include the frequency of oscillation and the time-averaged NOSfuel. Pulsed air flow on the DMFC did not show any such rise in voltage, supporting the hypothesis that a reduction in methanol crossover is the phenomenon which brings about enhanced performance.","abstract_html":"The effects of actively pulsing reactant flow rates into solid polymer electrolyte fuel cells were investigated in this thesis. First, work was conducted to determine the magnitude of voltage response to pulsed reactant flow on a direct hydrogen proton exchange membrane (PEM) cell. The effects of pulsed reactant flow into a direct methanol fuel cell (DMFC) were then considered. The PEM work showed substantially greater response to pulsed air flow than to pulsed fuel flow. It was found that several parameters affect the magnitude of cell response to active flow control (AFC). Increasing current load, increasing the magnitude of flow oscillation, decreasing the frequency of oscillation, and decreasing the average level of excess reactant supplied were found to maximize both the level of voltage oscillations and the decrease in cell power from steady state performance. Greater response to pulsed oxidant flow is believed to have been observed due to effects brought about by changes in membrane humidity. In contrast, pulsed fuel flow showed the greatest response in the study of DMFC technology. In this case, time averaged cell voltage was found to increase as the time averaged fuel flow rate was reduced. The increase in average cell power is the result of a reduction in methanol crossover; sustainable increases of up to 6% in power output were measured. The parameters found to effect the increase in cell power observed include the frequency of oscillation and the time-averaged NOSfuel. Pulsed air flow on the DMFC did not show any such rise in voltage, supporting the hypothesis that a reduction in methanol crossover is the phenomenon which brings about enhanced performance.","abstract_has_math":false,"creators":["Leahy, Scott B."],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["Parekh, David"],"committee_chairs":[],"committee_members":["Comas Haynes","Wepfer, William J."],"year":2004,"date_issued":"2004-04-09","date_published":"2004-04-09","updated_at":"2026-11-19T03:57:19Z","subjects":["Solid polymer electrolyte fuel cell","PEM","DMFC","Transient","Flow"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/5188","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/5188","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F5188","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Parekh, David"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Comas Haynes","Wepfer, William J."]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["George W. Woodruff School of Mechanical Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Leahy, Scott B."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2005-03-03T22:00:42Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2005-03-03T22:00:42Z"]},{"key":"dc:date.issued","label":"Date","values":["2004-04-09"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Master of Science in Mechanical Engineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["c01ff908-c25f-439b-bf10-a074ed886bb7","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["028ba2d8-6c6e-4f8a-a480-51b555d14e9d"]},{"key":"dc:type","label":"Dc Type","values":["Text","Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Solid polymer electrolyte fuel cell","PEM","DMFC","Transient","Flow"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/5188"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The effects of actively pulsing reactant flow rates into solid polymer electrolyte fuel cells were investigated in this thesis. First, work was conducted to determine the magnitude of voltage response to pulsed reactant flow on a direct hydrogen proton exchange membrane (PEM) cell. The effects of pulsed reactant flow into a direct methanol fuel cell (DMFC) were then considered. The PEM work showed substantially greater response to pulsed air flow than to pulsed fuel flow. It was found that several parameters affect the magnitude of cell response to active flow control (AFC). Increasing current load, increasing the magnitude of flow oscillation, decreasing the frequency of oscillation, and decreasing the average level of excess reactant supplied were found to maximize both the level of voltage oscillations and the decrease in cell power from steady state performance. Greater response to pulsed oxidant flow is believed to have been observed due to effects brought about by changes in membrane humidity. In contrast, pulsed fuel flow showed the greatest response in the study of DMFC technology. In this case, time averaged cell voltage was found to increase as the time averaged fuel flow rate was reduced. The increase in average cell power is the result of a reduction in methanol crossover; sustainable increases of up to 6% in power output were measured. The parameters found to effect the increase in cell power observed include the frequency of oscillation and the time-averaged NOSfuel. Pulsed air flow on the DMFC did not show any such rise in voltage, supporting the hypothesis that a reduction in methanol crossover is the phenomenon which brings about enhanced performance."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.S."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["841763 bytes"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Active Flow Control of Lab-Scale Solid Polymer Electrolyte Fuel Cells"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Parekh, David"],"dc:contributor.committeemember":["Comas Haynes","Wepfer, William J."],"dc:contributor.department":["Mechanical Engineering"],"dc:contributor.other":["George W. Woodruff School of Mechanical Engineering","College of Engineering"],"dc:creator":["Leahy, Scott B."],"dc:date.accessioned":["2005-03-03T22:00:42Z"],"dc:date.available":["2005-03-03T22:00:42Z"],"dc:date.issued":["2004-04-09"],"dc:description.abstract":["The effects of actively pulsing reactant flow rates into solid polymer electrolyte fuel cells were investigated in this thesis. First, work was conducted to determine the magnitude of voltage response to pulsed reactant flow on a direct hydrogen proton exchange membrane (PEM) cell. The effects of pulsed reactant flow into a direct methanol fuel cell (DMFC) were then considered. The PEM work showed substantially greater response to pulsed air flow than to pulsed fuel flow. It was found that several parameters affect the magnitude of cell response to active flow control (AFC). Increasing current load, increasing the magnitude of flow oscillation, decreasing the frequency of oscillation, and decreasing the average level of excess reactant supplied were found to maximize both the level of voltage oscillations and the decrease in cell power from steady state performance. Greater response to pulsed oxidant flow is believed to have been observed due to effects brought about by changes in membrane humidity. In contrast, pulsed fuel flow showed the greatest response in the study of DMFC technology. In this case, time averaged cell voltage was found to increase as the time averaged fuel flow rate was reduced. The increase in average cell power is the result of a reduction in methanol crossover; sustainable increases of up to 6% in power output were measured. The parameters found to effect the increase in cell power observed include the frequency of oscillation and the time-averaged NOSfuel. Pulsed air flow on the DMFC did not show any such rise in voltage, supporting the hypothesis that a reduction in methanol crossover is the phenomenon which brings about enhanced performance."],"dc:description.degree":["M.S."],"dc:format.extent":["841763 bytes"],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1853/5188"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.ispartofseries":["Master of Science in Mechanical Engineering"],"dc:relation.orgunit":["c01ff908-c25f-439b-bf10-a074ed886bb7","7c022d60-21d5-497c-b552-95e489a06569"],"dc:relation.seriesentity":["028ba2d8-6c6e-4f8a-a480-51b555d14e9d"],"dc:subject":["Solid polymer electrolyte fuel cell","PEM","DMFC","Transient","Flow"],"dc:title":["Active Flow Control of Lab-Scale Solid Polymer Electrolyte Fuel Cells"],"dc:type":["Text","Thesis"],"dspace:entity.type":["Publication"]},"updated_at":"2026-11-19T03:57:19Z"}