{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/51911"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/51911","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Characterization of HVAC operation uncertainty in EnergyPlus AHU modules","abstract":"This study addresses 5 uncertainties that exist in the operation of HVAC systems, which will presumably affect the actual energy consumption of the HVAC system in comparison to the consumption under idealized bahavior. We consequently add these parameters and their uncertainty range into the source code, eventually resulting in an EnergyPlus program in which the HVAC operation uncertainty is embedded as so-called model form uncertainty. The upgraded EnergyPlus is tested for each parameter uncertainty separately, and to show the impact of each uncertainty albeit for hypothetical uncertainty ranges of the parameters.","abstract_html":"This study addresses 5 uncertainties that exist in the operation of HVAC systems, which will presumably affect the actual energy consumption of the HVAC system in comparison to the consumption under idealized bahavior. We consequently add these parameters and their uncertainty range into the source code, eventually resulting in an EnergyPlus program in which the HVAC operation uncertainty is embedded as so-called model form uncertainty. The upgraded EnergyPlus is tested for each parameter uncertainty separately, and to show the impact of each uncertainty albeit for hypothetical uncertainty ranges of the parameters.","abstract_has_math":false,"creators":["Sui, Di"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Masters","degree_discipline":null,"degree_department":"Architecture","school":null,"contributors":[],"advisors":["Augenbroe, Godfried"],"committee_chairs":[],"committee_members":["Brown, Jason"],"year":2014,"date_issued":"2014-04-21","date_published":"2014-04-21","updated_at":"2026-11-19T05:58:30Z","subjects":["Building energy simulation","Uncertainty","EnergyPlus","Heating","Ventilation","Air conditioning","Energy consumption"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/51911","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/51911","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F51911","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Augenbroe, Godfried"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Brown, Jason"]},{"key":"dc:contributor.department","label":"Department","values":["Architecture"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["College of Design","School of Architecture"]},{"key":"dc:creator","label":"Author","values":["Sui, Di"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-05-22T15:36:08Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-05-22T15:36:08Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2014-05"]},{"key":"dc:date.issued","label":"Date","values":["2014-04-21"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["May 2014"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2014-05-22T15:36:08Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["7a1041d3-9298-48b6-bb90-f09619e6e744"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Master of Science in Architecture"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["c997b6a0-7e87-4a6f-b6fc-932d776ba8d0","0533a423-c95b-41cf-8e27-2faee06278ad"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["2443e7ba-a14f-4d51-b274-3577e65c6ce2"]},{"key":"dc:type","label":"Dc Type","values":["Text","Thesis"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Building energy simulation","Uncertainty","EnergyPlus"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Heating","Ventilation","Air conditioning","Energy consumption"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/51911"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This study addresses 5 uncertainties that exist in the operation of HVAC systems, which will presumably affect the actual energy consumption of the HVAC system in comparison to the consumption under idealized bahavior. We consequently add these parameters and their uncertainty range into the source code, eventually resulting in an EnergyPlus program in which the HVAC operation uncertainty is embedded as so-called model form uncertainty. The upgraded EnergyPlus is tested for each parameter uncertainty separately, and to show the impact of each uncertainty albeit for hypothetical uncertainty ranges of the parameters."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.S."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Characterization of HVAC operation uncertainty in EnergyPlus AHU modules"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Augenbroe, Godfried"],"dc:contributor.committeemember":["Brown, Jason"],"dc:contributor.department":["Architecture"],"dc:contributor.other":["College of Design","School of Architecture"],"dc:creator":["Sui, Di"],"dc:date.accessioned":["2014-05-22T15:36:08Z"],"dc:date.available":["2014-05-22T15:36:08Z"],"dc:date.created":["2014-05"],"dc:date.issued":["2014-04-21"],"dc:date.submitted":["May 2014"],"dc:date.updated":["2014-05-22T15:36:08Z"],"dc:description.abstract":["This study addresses 5 uncertainties that exist in the operation of HVAC systems, which will presumably affect the actual energy consumption of the HVAC system in comparison to the consumption under idealized bahavior. We consequently add these parameters and their uncertainty range into the source code, eventually resulting in an EnergyPlus program in which the HVAC operation uncertainty is embedded as so-called model form uncertainty. The upgraded EnergyPlus is tested for each parameter uncertainty separately, and to show the impact of each uncertainty albeit for hypothetical uncertainty ranges of the parameters."],"dc:description.degree":["M.S."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1853/51911"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["7a1041d3-9298-48b6-bb90-f09619e6e744"],"dc:relation.ispartofseries":["Master of Science in Architecture"],"dc:relation.orgunit":["c997b6a0-7e87-4a6f-b6fc-932d776ba8d0","0533a423-c95b-41cf-8e27-2faee06278ad"],"dc:relation.seriesentity":["2443e7ba-a14f-4d51-b274-3577e65c6ce2"],"dc:subject":["Building energy simulation","Uncertainty","EnergyPlus"],"dc:subject.lcsh":["Heating","Ventilation","Air conditioning","Energy consumption"],"dc:title":["Characterization of HVAC operation uncertainty in EnergyPlus AHU modules"],"dc:type":["Text","Thesis"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Masters"]},"updated_at":"2026-11-19T05:58:30Z"}