{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/51928"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/51928","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"A coarse mesh transport method for photons and electrons in 3-D","abstract":"A hybrid stochastic-deterministic method, COMET-PE, is developed for dose calculation in radiotherapy. Fast, accurate dose calculation is a key component of successful radiotherapy treatment. To calculate dose, COMET-PE solves the coupled Boltzmann Transport Equations for photons and electrons. The method uses a deterministic iteration to compose response functions that are pre-computed using Monte Carlo. Thus, COMET-PE takes advantage of Monte Carlo physics without incurring the computational costs typically required for statistical convergence. This work extends the method to 3-D problems with realistic source distributions. Additionally, the performance of the deterministic solver is improved, taking advantage of both shared-memory and distributed-memory parallelism to enhance efficiency. To verify the method’s accuracy, it is compared with the DOSXYZnrc (Monte Carlo) method using three different benchmark problems: a heterogeneous slab phantom, a water phantom, and a CT-based lung phantom. For the slab phantom, all errors are less than 1.5% of the maximum dose or less than 3% of local dose. For both the water phantom and the lung phantom, over 97% of voxels receiving greater than 10% of the maximum dose pass a 2% (relative error) / 2 mm (distance-to-agreement) test. Timing comparisons show that COMET-PE is roughly 10-30 times faster than DOSXYZnrc. Thus, the new method provides a fast, accurate alternative to Monte Carlo for dose calculation in radiotherapy treatment planning.","abstract_html":"A hybrid stochastic-deterministic method, COMET-PE, is developed for dose calculation in radiotherapy. Fast, accurate dose calculation is a key component of successful radiotherapy treatment. To calculate dose, COMET-PE solves the coupled Boltzmann Transport Equations for photons and electrons. The method uses a deterministic iteration to compose response functions that are pre-computed using Monte Carlo. Thus, COMET-PE takes advantage of Monte Carlo physics without incurring the computational costs typically required for statistical convergence. This work extends the method to 3-D problems with realistic source distributions. Additionally, the performance of the deterministic solver is improved, taking advantage of both shared-memory and distributed-memory parallelism to enhance efficiency. To verify the method’s accuracy, it is compared with the DOSXYZnrc (Monte Carlo) method using three different benchmark problems: a heterogeneous slab phantom, a water phantom, and a CT-based lung phantom. For the slab phantom, all errors are less than 1.5% of the maximum dose or less than 3% of local dose. For both the water phantom and the lung phantom, over 97% of voxels receiving greater than 10% of the maximum dose pass a 2% (relative error) / 2 mm (distance-to-agreement) test. Timing comparisons show that COMET-PE is roughly 10-30 times faster than DOSXYZnrc. Thus, the new method provides a fast, accurate alternative to Monte Carlo for dose calculation in radiotherapy treatment planning.","abstract_has_math":false,"creators":["Hayward, Robert M."],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Doctoral","degree_discipline":null,"degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["Rahnema, Farzad"],"committee_chairs":[],"committee_members":["Elder, Eric","Morely, Thomas","Wang, Chris K.","Zhang, Dingkang"],"year":2013,"date_issued":"2013-04-09","date_published":"2013-04-09","updated_at":"2026-11-19T05:12:13Z","subjects":["Monte Carlo","Treatment planning","Transport theory","Radiotherapy","Radiation Dosage","Monte Carlo method","Medical physics"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/51928","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/51928","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F51928","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Rahnema, Farzad"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Elder, Eric","Morely, Thomas","Wang, Chris K.","Zhang, Dingkang"]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["George W. Woodruff School of Mechanical Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Hayward, Robert M."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-05-28T21:02:12Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-05-28T21:02:12Z"]},{"key":"dc:date.issued","label":"Date","values":["2013-04-09"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["1d96b222-d2f0-46d1-a0c7-4d1f9254dfab"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Doctor of Philosophy with a Major in Nuclear Engineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["c01ff908-c25f-439b-bf10-a074ed886bb7","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["b2bc2e12-2afc-4a4d-bf4c-0ce7832bcefe"]},{"key":"dc:type","label":"Dc Type","values":["Text","Dissertation"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctoral"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Monte Carlo","Treatment planning","Transport theory"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Radiotherapy","Radiation Dosage","Monte Carlo method","Medical physics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/51928"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A hybrid stochastic-deterministic method, COMET-PE, is developed for dose calculation in radiotherapy. Fast, accurate dose calculation is a key component of successful radiotherapy treatment. To calculate dose, COMET-PE solves the coupled Boltzmann Transport Equations for photons and electrons. The method uses a deterministic iteration to compose response functions that are pre-computed using Monte Carlo. Thus, COMET-PE takes advantage of Monte Carlo physics without incurring the computational costs typically required for statistical convergence. This work extends the method to 3-D problems with realistic source distributions. Additionally, the performance of the deterministic solver is improved, taking advantage of both shared-memory and distributed-memory parallelism to enhance efficiency. To verify the method’s accuracy, it is compared with the DOSXYZnrc (Monte Carlo) method using three different benchmark problems: a heterogeneous slab phantom, a water phantom, and a CT-based lung phantom. For the slab phantom, all errors are less than 1.5% of the maximum dose or less than 3% of local dose. For both the water phantom and the lung phantom, over 97% of voxels receiving greater than 10% of the maximum dose pass a 2% (relative error) / 2 mm (distance-to-agreement) test. Timing comparisons show that COMET-PE is roughly 10-30 times faster than DOSXYZnrc. Thus, the new method provides a fast, accurate alternative to Monte Carlo for dose calculation in radiotherapy treatment planning."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph.D."]},{"key":"dc:embargo.terms","label":"Dc Embargo Terms","values":["null"]},{"key":"dc:title","label":"Title","values":["A coarse mesh transport method for photons and electrons in 3-D"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Rahnema, Farzad"],"dc:contributor.committeemember":["Elder, Eric","Morely, Thomas","Wang, Chris K.","Zhang, Dingkang"],"dc:contributor.department":["Mechanical Engineering"],"dc:contributor.other":["George W. Woodruff School of Mechanical Engineering","College of Engineering"],"dc:creator":["Hayward, Robert M."],"dc:date.accessioned":["2014-05-28T21:02:12Z"],"dc:date.available":["2014-05-28T21:02:12Z"],"dc:date.issued":["2013-04-09"],"dc:description.abstract":["A hybrid stochastic-deterministic method, COMET-PE, is developed for dose calculation in radiotherapy. Fast, accurate dose calculation is a key component of successful radiotherapy treatment. To calculate dose, COMET-PE solves the coupled Boltzmann Transport Equations for photons and electrons. The method uses a deterministic iteration to compose response functions that are pre-computed using Monte Carlo. Thus, COMET-PE takes advantage of Monte Carlo physics without incurring the computational costs typically required for statistical convergence. This work extends the method to 3-D problems with realistic source distributions. Additionally, the performance of the deterministic solver is improved, taking advantage of both shared-memory and distributed-memory parallelism to enhance efficiency. To verify the method’s accuracy, it is compared with the DOSXYZnrc (Monte Carlo) method using three different benchmark problems: a heterogeneous slab phantom, a water phantom, and a CT-based lung phantom. For the slab phantom, all errors are less than 1.5% of the maximum dose or less than 3% of local dose. For both the water phantom and the lung phantom, over 97% of voxels receiving greater than 10% of the maximum dose pass a 2% (relative error) / 2 mm (distance-to-agreement) test. Timing comparisons show that COMET-PE is roughly 10-30 times faster than DOSXYZnrc. Thus, the new method provides a fast, accurate alternative to Monte Carlo for dose calculation in radiotherapy treatment planning."],"dc:description.degree":["Ph.D."],"dc:embargo.terms":["null"],"dc:identifier.uri":["http://hdl.handle.net/1853/51928"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["1d96b222-d2f0-46d1-a0c7-4d1f9254dfab"],"dc:relation.ispartofseries":["Doctor of Philosophy with a Major in Nuclear Engineering"],"dc:relation.orgunit":["c01ff908-c25f-439b-bf10-a074ed886bb7","7c022d60-21d5-497c-b552-95e489a06569"],"dc:relation.seriesentity":["b2bc2e12-2afc-4a4d-bf4c-0ce7832bcefe"],"dc:subject":["Monte Carlo","Treatment planning","Transport theory"],"dc:subject.lcsh":["Radiotherapy","Radiation Dosage","Monte Carlo method","Medical physics"],"dc:title":["A coarse mesh transport method for photons and electrons in 3-D"],"dc:type":["Text","Dissertation"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Doctoral"]},"updated_at":"2026-11-19T05:12:13Z"}