{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/52208"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/52208","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Characterization of lymphatic pump function in response to mechanical loading","abstract":"The lymphatic system is crucial for normal physiologic function, performing such basic functions as maintaining tissue fluid balance, trafficking immune cells, draining interstitial proteins, as well as transporting fat from the intestine to the blood. To perform these functions properly, downstream vessels (known as collecting lymphatics) actively pump like the heart to dynamically propel lymph from the interstitial spaces of the body to the blood vasculature. However, despite the fact that lymphatics are so important, there exists very little knowledge regarding the details of this active pumping. Specifically, it is known that external mechanical loading such as fluid shear stress and circumferential stress due to transmural pressure affect pumping response; however, anything other than simple, static relationships remain unknown. Because mechanical environment has been implicated in lymphatic diseases such as lymphedema, understanding these dynamic relationships between lymphatic pumping and mechanical loading during normal function are crucial to grasp before these pathologies can be unraveled. For this reason, this thesis describes several tools developed to study lymphatic function in response to the unique mechanical loads these vessels experience both in vitro and ex vivo. Moreover, this work investigates how shear stress sensitivity is affected by transmural pressure and how the presence of dynamic shear independently affects lymphatic contractile function.","abstract_html":"The lymphatic system is crucial for normal physiologic function, performing such basic functions as maintaining tissue fluid balance, trafficking immune cells, draining interstitial proteins, as well as transporting fat from the intestine to the blood. To perform these functions properly, downstream vessels (known as collecting lymphatics) actively pump like the heart to dynamically propel lymph from the interstitial spaces of the body to the blood vasculature. However, despite the fact that lymphatics are so important, there exists very little knowledge regarding the details of this active pumping. Specifically, it is known that external mechanical loading such as fluid shear stress and circumferential stress due to transmural pressure affect pumping response; however, anything other than simple, static relationships remain unknown. Because mechanical environment has been implicated in lymphatic diseases such as lymphedema, understanding these dynamic relationships between lymphatic pumping and mechanical loading during normal function are crucial to grasp before these pathologies can be unraveled. For this reason, this thesis describes several tools developed to study lymphatic function in response to the unique mechanical loads these vessels experience both in vitro and ex vivo. Moreover, this work investigates how shear stress sensitivity is affected by transmural pressure and how the presence of dynamic shear independently affects lymphatic contractile function.","abstract_has_math":false,"creators":["Kornuta, Jeffrey Alan"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Doctoral","degree_discipline":null,"degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["Dixon, J. Brandon"],"committee_chairs":[],"committee_members":["Ueda, Jun","Gleason, Rudolpoh L.","Yoganathan, Ajit P.","Stanley, Garrett B."],"year":2014,"date_issued":"2014-04-28","date_published":"2014-04-28","updated_at":"2026-11-19T06:00:38Z","subjects":["Lymphatic biomechanics","Vascular perfusion system","Model predictive control","Dynamic shear stress"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/52208","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/52208","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F52208","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Dixon, J. Brandon"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Ueda, Jun","Gleason, Rudolpoh L.","Yoganathan, Ajit P.","Stanley, Garrett B."]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["George W. Woodruff School of Mechanical Engineering","College of Engineering","Institute for Robotics and Intelligent Machines (IRIM)"]},{"key":"dc:creator","label":"Author","values":["Kornuta, Jeffrey Alan"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-08-27T13:33:24Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-08-27T13:33:24Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2014-08"]},{"key":"dc:date.issued","label":"Date","values":["2014-04-28"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["August 2014"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2014-08-27T13:33:24Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["9f14783f-ad69-4a5d-9032-e1d19c3a41ca"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["c01ff908-c25f-439b-bf10-a074ed886bb7","7c022d60-21d5-497c-b552-95e489a06569","66259949-abfd-45c2-9dcc-5a6f2c013bcf"]},{"key":"dc:type","label":"Dc Type","values":["Text","Dissertation"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctoral"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Lymphatic biomechanics","Vascular perfusion system","Model predictive control","Dynamic shear stress"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/52208"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The lymphatic system is crucial for normal physiologic function, performing such basic functions as maintaining tissue fluid balance, trafficking immune cells, draining interstitial proteins, as well as transporting fat from the intestine to the blood. To perform these functions properly, downstream vessels (known as collecting lymphatics) actively pump like the heart to dynamically propel lymph from the interstitial spaces of the body to the blood vasculature. However, despite the fact that lymphatics are so important, there exists very little knowledge regarding the details of this active pumping. Specifically, it is known that external mechanical loading such as fluid shear stress and circumferential stress due to transmural pressure affect pumping response; however, anything other than simple, static relationships remain unknown. Because mechanical environment has been implicated in lymphatic diseases such as lymphedema, understanding these dynamic relationships between lymphatic pumping and mechanical loading during normal function are crucial to grasp before these pathologies can be unraveled. For this reason, this thesis describes several tools developed to study lymphatic function in response to the unique mechanical loads these vessels experience both in vitro and ex vivo. Moreover, this work investigates how shear stress sensitivity is affected by transmural pressure and how the presence of dynamic shear independently affects lymphatic contractile function."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph.D."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Characterization of lymphatic pump function in response to mechanical loading"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Dixon, J. Brandon"],"dc:contributor.committeemember":["Ueda, Jun","Gleason, Rudolpoh L.","Yoganathan, Ajit P.","Stanley, Garrett B."],"dc:contributor.department":["Mechanical Engineering"],"dc:contributor.other":["George W. Woodruff School of Mechanical Engineering","College of Engineering","Institute for Robotics and Intelligent Machines (IRIM)"],"dc:creator":["Kornuta, Jeffrey Alan"],"dc:date.accessioned":["2014-08-27T13:33:24Z"],"dc:date.available":["2014-08-27T13:33:24Z"],"dc:date.created":["2014-08"],"dc:date.issued":["2014-04-28"],"dc:date.submitted":["August 2014"],"dc:date.updated":["2014-08-27T13:33:24Z"],"dc:description.abstract":["The lymphatic system is crucial for normal physiologic function, performing such basic functions as maintaining tissue fluid balance, trafficking immune cells, draining interstitial proteins, as well as transporting fat from the intestine to the blood. To perform these functions properly, downstream vessels (known as collecting lymphatics) actively pump like the heart to dynamically propel lymph from the interstitial spaces of the body to the blood vasculature. However, despite the fact that lymphatics are so important, there exists very little knowledge regarding the details of this active pumping. Specifically, it is known that external mechanical loading such as fluid shear stress and circumferential stress due to transmural pressure affect pumping response; however, anything other than simple, static relationships remain unknown. Because mechanical environment has been implicated in lymphatic diseases such as lymphedema, understanding these dynamic relationships between lymphatic pumping and mechanical loading during normal function are crucial to grasp before these pathologies can be unraveled. For this reason, this thesis describes several tools developed to study lymphatic function in response to the unique mechanical loads these vessels experience both in vitro and ex vivo. Moreover, this work investigates how shear stress sensitivity is affected by transmural pressure and how the presence of dynamic shear independently affects lymphatic contractile function."],"dc:description.degree":["Ph.D."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1853/52208"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["9f14783f-ad69-4a5d-9032-e1d19c3a41ca"],"dc:relation.orgunit":["c01ff908-c25f-439b-bf10-a074ed886bb7","7c022d60-21d5-497c-b552-95e489a06569","66259949-abfd-45c2-9dcc-5a6f2c013bcf"],"dc:subject":["Lymphatic biomechanics","Vascular perfusion system","Model predictive control","Dynamic shear stress"],"dc:title":["Characterization of lymphatic pump function in response to mechanical loading"],"dc:type":["Text","Dissertation"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Doctoral"]},"updated_at":"2026-11-19T06:00:38Z"}