{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/5284"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/5284","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Development of an Improved Dissipative Passive Haptic Display","abstract":"This project focuses on the design and modeling of a two degree-of-freedom dissipative passive haptic display. Haptic displays are man-machine interfaces that transmit forces to the human operator. A dissipative passive haptic display is one that may only remove energy from the system using actuators such as brakes and dampers, thus ensuring the safety of the human operator. These devices may be used to implement virtual constraints such as desired paths and obstacles. Traditional friction brakes have previously been used as dissipative and coupling elements in a two degree-of-freedom parallel manipulator, resulting in undesired effects such as vibration, stiction, and slow response times. Alternatively, the new robot is actuated by rheological brakes, which feature fast response times and smooth application of torque. This approach aims to improve upon the accuracy and feel of the previous design. A commercial magnetorheological (MR) fluid brake was selected and put through an extensive series of tests. The data was used to develop a model that characterizes MR fluid behavior in low speed braking applications. A parallel five bar linkage was designed and built that has separate configurations corresponding to 3-brake and 4-brake operation. The length of each arm was chosen by means of a geometrical optimization that weighs the size and area of the workspace and actuator effects. A simulation was then developed by incorporating the brake model into the equations of motion of the robot. Next, two forms of path following velocity control were devised and tested in simulation. Finally, the accuracy, workload, and smoothness of both controllers and both configurations were examined in preliminary tests with human operators.","abstract_html":"This project focuses on the design and modeling of a two degree-of-freedom dissipative passive haptic display. Haptic displays are man-machine interfaces that transmit forces to the human operator. A dissipative passive haptic display is one that may only remove energy from the system using actuators such as brakes and dampers, thus ensuring the safety of the human operator. These devices may be used to implement virtual constraints such as desired paths and obstacles. Traditional friction brakes have previously been used as dissipative and coupling elements in a two degree-of-freedom parallel manipulator, resulting in undesired effects such as vibration, stiction, and slow response times. Alternatively, the new robot is actuated by rheological brakes, which feature fast response times and smooth application of torque. This approach aims to improve upon the accuracy and feel of the previous design. A commercial magnetorheological (MR) fluid brake was selected and put through an extensive series of tests. The data was used to develop a model that characterizes MR fluid behavior in low speed braking applications. A parallel five bar linkage was designed and built that has separate configurations corresponding to 3-brake and 4-brake operation. The length of each arm was chosen by means of a geometrical optimization that weighs the size and area of the workspace and actuator effects. A simulation was then developed by incorporating the brake model into the equations of motion of the robot. Next, two forms of path following velocity control were devised and tested in simulation. Finally, the accuracy, workload, and smoothness of both controllers and both configurations were examined in preliminary tests with human operators.","abstract_has_math":false,"creators":["Reed, Matthew Robert"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["Book, Wayne J."],"committee_chairs":[],"committee_members":["Ferri, Aldo A.","Ebert-Uphoff, Imme"],"year":2003,"date_issued":"2003-11-25","date_published":"2003-11-25","updated_at":"2026-11-19T06:07:26Z","subjects":["ER","MR","Robot","Passive","Electrorheological","Magnetorheological","Human","Modeling","Simulation","Fluid","Brakes","Haptics","Control","Testing","Robots Control systems Safety measures","Brakes Control systems","Human-machine systems Design and construction Safety measures","Robots Control systems Design and construction"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/5284","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/5284","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F5284","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Book, Wayne J."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Ferri, Aldo A.","Ebert-Uphoff, Imme"]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["George W. Woodruff School of Mechanical Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Reed, Matthew Robert"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2005-03-04T16:42:23Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2005-03-04T16:42:23Z"]},{"key":"dc:date.issued","label":"Date","values":["2003-11-25"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["45966a3c-59ea-44fc-980a-96d543c035f0"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Master of Science in Mechanical Engineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["c01ff908-c25f-439b-bf10-a074ed886bb7","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["028ba2d8-6c6e-4f8a-a480-51b555d14e9d"]},{"key":"dc:type","label":"Dc Type","values":["Text","Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["ER","MR","Robot","Passive","Electrorheological","Magnetorheological","Human","Modeling","Simulation","Fluid","Brakes","Haptics","Control","Testing"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Robots Control systems Safety measures","Brakes Control systems","Human-machine systems Design and construction Safety measures","Robots Control systems Design and construction"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/5284"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This project focuses on the design and modeling of a two degree-of-freedom dissipative passive haptic display. Haptic displays are man-machine interfaces that transmit forces to the human operator. A dissipative passive haptic display is one that may only remove energy from the system using actuators such as brakes and dampers, thus ensuring the safety of the human operator. These devices may be used to implement virtual constraints such as desired paths and obstacles. Traditional friction brakes have previously been used as dissipative and coupling elements in a two degree-of-freedom parallel manipulator, resulting in undesired effects such as vibration, stiction, and slow response times. Alternatively, the new robot is actuated by rheological brakes, which feature fast response times and smooth application of torque. This approach aims to improve upon the accuracy and feel of the previous design. A commercial magnetorheological (MR) fluid brake was selected and put through an extensive series of tests. The data was used to develop a model that characterizes MR fluid behavior in low speed braking applications. A parallel five bar linkage was designed and built that has separate configurations corresponding to 3-brake and 4-brake operation. The length of each arm was chosen by means of a geometrical optimization that weighs the size and area of the workspace and actuator effects. A simulation was then developed by incorporating the brake model into the equations of motion of the robot. Next, two forms of path following velocity control were devised and tested in simulation. Finally, the accuracy, workload, and smoothness of both controllers and both configurations were examined in preliminary tests with human operators."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.S."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["2302225 bytes"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Development of an Improved Dissipative Passive Haptic Display"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Book, Wayne J."],"dc:contributor.committeemember":["Ferri, Aldo A.","Ebert-Uphoff, Imme"],"dc:contributor.department":["Mechanical Engineering"],"dc:contributor.other":["George W. Woodruff School of Mechanical Engineering","College of Engineering"],"dc:creator":["Reed, Matthew Robert"],"dc:date.accessioned":["2005-03-04T16:42:23Z"],"dc:date.available":["2005-03-04T16:42:23Z"],"dc:date.issued":["2003-11-25"],"dc:description.abstract":["This project focuses on the design and modeling of a two degree-of-freedom dissipative passive haptic display. Haptic displays are man-machine interfaces that transmit forces to the human operator. A dissipative passive haptic display is one that may only remove energy from the system using actuators such as brakes and dampers, thus ensuring the safety of the human operator. These devices may be used to implement virtual constraints such as desired paths and obstacles. Traditional friction brakes have previously been used as dissipative and coupling elements in a two degree-of-freedom parallel manipulator, resulting in undesired effects such as vibration, stiction, and slow response times. Alternatively, the new robot is actuated by rheological brakes, which feature fast response times and smooth application of torque. This approach aims to improve upon the accuracy and feel of the previous design. A commercial magnetorheological (MR) fluid brake was selected and put through an extensive series of tests. The data was used to develop a model that characterizes MR fluid behavior in low speed braking applications. A parallel five bar linkage was designed and built that has separate configurations corresponding to 3-brake and 4-brake operation. The length of each arm was chosen by means of a geometrical optimization that weighs the size and area of the workspace and actuator effects. A simulation was then developed by incorporating the brake model into the equations of motion of the robot. Next, two forms of path following velocity control were devised and tested in simulation. Finally, the accuracy, workload, and smoothness of both controllers and both configurations were examined in preliminary tests with human operators."],"dc:description.degree":["M.S."],"dc:format.extent":["2302225 bytes"],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1853/5284"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["45966a3c-59ea-44fc-980a-96d543c035f0"],"dc:relation.ispartofseries":["Master of Science in Mechanical Engineering"],"dc:relation.orgunit":["c01ff908-c25f-439b-bf10-a074ed886bb7","7c022d60-21d5-497c-b552-95e489a06569"],"dc:relation.seriesentity":["028ba2d8-6c6e-4f8a-a480-51b555d14e9d"],"dc:subject":["ER","MR","Robot","Passive","Electrorheological","Magnetorheological","Human","Modeling","Simulation","Fluid","Brakes","Haptics","Control","Testing"],"dc:subject.lcsh":["Robots Control systems Safety measures","Brakes Control systems","Human-machine systems Design and construction Safety measures","Robots Control systems Design and construction"],"dc:title":["Development of an Improved Dissipative Passive Haptic Display"],"dc:type":["Text","Thesis"],"dspace:entity.type":["Publication"]},"updated_at":"2026-11-19T06:07:26Z"}