{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/52977"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/52977","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"A study on the heat transfer and energy performance implications of cool roofs","abstract":"In this study, we examined the effect of cool roofs on commercial and residential buildings in each climate zone, by looking at monitored case studies and DOE-2 simulations from various sources of literature; and using an online tool - the Cool Roof Calculator and a simple COP ratio model to validate the results of the case studies. It was found that the Cool Roof Calculator does not take building form into account, hence a sensitivity analysis was first conducted to rank the importance of various building parameters against one another. The analysis was conducted on the EPC normative building energy model. Results indicated that roof absorptance coefficient, aspect ratio and number of floors were the three parameters that either ranked highest or were important parameters, and were chosen for further parametric analysis to evaluate the impact of these building parameters on total building loads. A simple COP ratio model was also developed to validate the results from the literature review and Cool Roof Calculator, and it was found that in terms of cost, for a prototype medium-sized commercial building, it is always beneficial to use a white roof, but cities in northern climates may have little advantage, and insulation may be a better choice.","abstract_html":"In this study, we examined the effect of cool roofs on commercial and residential buildings in each climate zone, by looking at monitored case studies and DOE-2 simulations from various sources of literature; and using an online tool - the Cool Roof Calculator and a simple COP ratio model to validate the results of the case studies. It was found that the Cool Roof Calculator does not take building form into account, hence a sensitivity analysis was first conducted to rank the importance of various building parameters against one another. The analysis was conducted on the EPC normative building energy model. Results indicated that roof absorptance coefficient, aspect ratio and number of floors were the three parameters that either ranked highest or were important parameters, and were chosen for further parametric analysis to evaluate the impact of these building parameters on total building loads. A simple COP ratio model was also developed to validate the results from the literature review and Cool Roof Calculator, and it was found that in terms of cost, for a prototype medium-sized commercial building, it is always beneficial to use a white roof, but cities in northern climates may have little advantage, and insulation may be a better choice.","abstract_has_math":false,"creators":["Zhang, Tianyao"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Masters","degree_discipline":null,"degree_department":"Architecture","school":null,"contributors":[],"advisors":["Brown, Jason"],"committee_chairs":[],"committee_members":["Augenbroe, Godfried","Haymaker, John"],"year":2013,"date_issued":"2013-11-26","date_published":"2013-11-26","updated_at":"2026-11-19T05:15:25Z","subjects":["Cool roofs","Heating penalty","Sensitivity analysis","Parametric studies"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/52977","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/52977","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F52977","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Brown, Jason"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Augenbroe, Godfried","Haymaker, John"]},{"key":"dc:contributor.department","label":"Department","values":["Architecture"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["College of Design","School of Architecture"]},{"key":"dc:creator","label":"Author","values":["Zhang, Tianyao"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2015-01-12T20:43:34Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2015-01-13T06:30:04Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2013-12"]},{"key":"dc:date.issued","label":"Date","values":["2013-11-26"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["December 2013"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2015-01-12T20:43:34Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Master of Science in Architecture"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["c997b6a0-7e87-4a6f-b6fc-932d776ba8d0","0533a423-c95b-41cf-8e27-2faee06278ad"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["2443e7ba-a14f-4d51-b274-3577e65c6ce2"]},{"key":"dc:type","label":"Dc Type","values":["Text","Thesis"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Cool roofs","Heating penalty","Sensitivity analysis","Parametric studies"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/52977"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["In this study, we examined the effect of cool roofs on commercial and residential buildings in each climate zone, by looking at monitored case studies and DOE-2 simulations from various sources of literature; and using an online tool - the Cool Roof Calculator and a simple COP ratio model to validate the results of the case studies. It was found that the Cool Roof Calculator does not take building form into account, hence a sensitivity analysis was first conducted to rank the importance of various building parameters against one another. The analysis was conducted on the EPC normative building energy model. Results indicated that roof absorptance coefficient, aspect ratio and number of floors were the three parameters that either ranked highest or were important parameters, and were chosen for further parametric analysis to evaluate the impact of these building parameters on total building loads. A simple COP ratio model was also developed to validate the results from the literature review and Cool Roof Calculator, and it was found that in terms of cost, for a prototype medium-sized commercial building, it is always beneficial to use a white roof, but cities in northern climates may have little advantage, and insulation may be a better choice."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.S."]},{"key":"dc:embargo.terms","label":"Dc Embargo Terms","values":["2014-12-01"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["A study on the heat transfer and energy performance implications of cool roofs"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Brown, Jason"],"dc:contributor.committeemember":["Augenbroe, Godfried","Haymaker, John"],"dc:contributor.department":["Architecture"],"dc:contributor.other":["College of Design","School of Architecture"],"dc:creator":["Zhang, Tianyao"],"dc:date.accessioned":["2015-01-12T20:43:34Z"],"dc:date.available":["2015-01-13T06:30:04Z"],"dc:date.created":["2013-12"],"dc:date.issued":["2013-11-26"],"dc:date.submitted":["December 2013"],"dc:date.updated":["2015-01-12T20:43:34Z"],"dc:description.abstract":["In this study, we examined the effect of cool roofs on commercial and residential buildings in each climate zone, by looking at monitored case studies and DOE-2 simulations from various sources of literature; and using an online tool - the Cool Roof Calculator and a simple COP ratio model to validate the results of the case studies. It was found that the Cool Roof Calculator does not take building form into account, hence a sensitivity analysis was first conducted to rank the importance of various building parameters against one another. The analysis was conducted on the EPC normative building energy model. Results indicated that roof absorptance coefficient, aspect ratio and number of floors were the three parameters that either ranked highest or were important parameters, and were chosen for further parametric analysis to evaluate the impact of these building parameters on total building loads. A simple COP ratio model was also developed to validate the results from the literature review and Cool Roof Calculator, and it was found that in terms of cost, for a prototype medium-sized commercial building, it is always beneficial to use a white roof, but cities in northern climates may have little advantage, and insulation may be a better choice."],"dc:description.degree":["M.S."],"dc:embargo.terms":["2014-12-01"],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1853/52977"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.ispartofseries":["Master of Science in Architecture"],"dc:relation.orgunit":["c997b6a0-7e87-4a6f-b6fc-932d776ba8d0","0533a423-c95b-41cf-8e27-2faee06278ad"],"dc:relation.seriesentity":["2443e7ba-a14f-4d51-b274-3577e65c6ce2"],"dc:subject":["Cool roofs","Heating penalty","Sensitivity analysis","Parametric studies"],"dc:title":["A study on the heat transfer and energy performance implications of cool roofs"],"dc:type":["Text","Thesis"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Masters"]},"updated_at":"2026-11-19T05:15:25Z"}