{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/53449"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/53449","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"A power-efficient wireless neural stimulating system with inductive power transmission","abstract":"The objective of the proposed research is to advance the power efficiency of wireless neural stimulating systems in inductively powered implantable medical devices (IMD). Several innovative system- and circuit-level techniques are proposed towards the development of power-management circuits and wireless neural stimulating systems with inductive power transmission to improve the overall stimulation power efficiency. Neural stimulating IMDs have been proven as effective therapies to alleviate neurological diseases, while requiring high power and performance for more efficacious treatments. Therefore, power-management circuits and neural stimulators in IMDs should have high power efficiencies to operate with smaller received power from a larger distance. Neural stimulating systems are also required to have high stimulation efficacy for activating the target tissue with a minimum amount of energy, while ensuring charge-balanced stimulation. These features provide several advantages such as a long battery life in an external power transmitter, extended-range inductive power transfer, efficacious and safe stimulation, and less tissue damage from overheating. The proposed research presents several approaches to design and implement the power-efficient wireless neural stimulating IMDs: 1) optimized power-management circuits for inductively powered biomedical microsystems, 2) a power-efficient neural stimulating system with adaptive supply control, and 3) a wireless switched-capacitor stimulation (SCS) system, which is a combination structure of the power-management circuits and neural stimulator, to maximize both stimulator efficiency (before electrodes) and stimulus efficacy (after electrodes).","abstract_html":"The objective of the proposed research is to advance the power efficiency of wireless neural stimulating systems in inductively powered implantable medical devices (IMD). Several innovative system- and circuit-level techniques are proposed towards the development of power-management circuits and wireless neural stimulating systems with inductive power transmission to improve the overall stimulation power efficiency. Neural stimulating IMDs have been proven as effective therapies to alleviate neurological diseases, while requiring high power and performance for more efficacious treatments. Therefore, power-management circuits and neural stimulators in IMDs should have high power efficiencies to operate with smaller received power from a larger distance. Neural stimulating systems are also required to have high stimulation efficacy for activating the target tissue with a minimum amount of energy, while ensuring charge-balanced stimulation. These features provide several advantages such as a long battery life in an external power transmitter, extended-range inductive power transfer, efficacious and safe stimulation, and less tissue damage from overheating. The proposed research presents several approaches to design and implement the power-efficient wireless neural stimulating IMDs: 1) optimized power-management circuits for inductively powered biomedical microsystems, 2) a power-efficient neural stimulating system with adaptive supply control, and 3) a wireless switched-capacitor stimulation (SCS) system, which is a combination structure of the power-management circuits and neural stimulator, to maximize both stimulator efficiency (before electrodes) and stimulus efficacy (after electrodes).","abstract_has_math":false,"creators":["Lee, Hyung-Min"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Doctoral","degree_discipline":null,"degree_department":"Electrical and Computer Engineering","school":null,"contributors":[],"advisors":["Ghovanloo, Maysam"],"committee_chairs":[],"committee_members":["Ayazi, Farrokh","Wang, Hua","Bhatti, Pamela","Li, Wen"],"year":2014,"date_issued":"2014-04-03","date_published":"2014-04-03","updated_at":"2026-11-19T04:14:06Z","subjects":["Neural stimulation","Wireless power transfer","Switched-capacitor based stimulator","Implantable medical device","Inductive link","Optogenetics","Tissue modeling"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/53449","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/53449","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F53449","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Ghovanloo, Maysam"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Ayazi, Farrokh","Wang, Hua","Bhatti, Pamela","Li, Wen"]},{"key":"dc:contributor.department","label":"Department","values":["Electrical and Computer Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["School of Electrical and Computer Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Lee, Hyung-Min"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2015-06-08T18:14:37Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2015-06-09T05:30:07Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2014-05"]},{"key":"dc:date.issued","label":"Date","values":["2014-04-03"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["May 2014"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2015-06-08T18:14:37Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Doctor of Philosophy with a Major in Electrical and Computer Engineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["5b7adef2-447c-4270-b9fc-846bd76f80f2","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["3890cd56-8ecf-424b-8074-8f5ebd8dbe15"]},{"key":"dc:type","label":"Dc Type","values":["Text","Dissertation"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctoral"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Neural stimulation","Wireless power transfer","Switched-capacitor based stimulator","Implantable medical device","Inductive link","Optogenetics","Tissue modeling"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/53449"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The objective of the proposed research is to advance the power efficiency of wireless neural stimulating systems in inductively powered implantable medical devices (IMD). Several innovative system- and circuit-level techniques are proposed towards the development of power-management circuits and wireless neural stimulating systems with inductive power transmission to improve the overall stimulation power efficiency. Neural stimulating IMDs have been proven as effective therapies to alleviate neurological diseases, while requiring high power and performance for more efficacious treatments. Therefore, power-management circuits and neural stimulators in IMDs should have high power efficiencies to operate with smaller received power from a larger distance. Neural stimulating systems are also required to have high stimulation efficacy for activating the target tissue with a minimum amount of energy, while ensuring charge-balanced stimulation. These features provide several advantages such as a long battery life in an external power transmitter, extended-range inductive power transfer, efficacious and safe stimulation, and less tissue damage from overheating. The proposed research presents several approaches to design and implement the power-efficient wireless neural stimulating IMDs: 1) optimized power-management circuits for inductively powered biomedical microsystems, 2) a power-efficient neural stimulating system with adaptive supply control, and 3) a wireless switched-capacitor stimulation (SCS) system, which is a combination structure of the power-management circuits and neural stimulator, to maximize both stimulator efficiency (before electrodes) and stimulus efficacy (after electrodes)."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph.D."]},{"key":"dc:embargo.terms","label":"Dc Embargo Terms","values":["2015-05-01"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["A power-efficient wireless neural stimulating system with inductive power transmission"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Ghovanloo, Maysam"],"dc:contributor.committeemember":["Ayazi, Farrokh","Wang, Hua","Bhatti, Pamela","Li, Wen"],"dc:contributor.department":["Electrical and Computer Engineering"],"dc:contributor.other":["School of Electrical and Computer Engineering","College of Engineering"],"dc:creator":["Lee, Hyung-Min"],"dc:date.accessioned":["2015-06-08T18:14:37Z"],"dc:date.available":["2015-06-09T05:30:07Z"],"dc:date.created":["2014-05"],"dc:date.issued":["2014-04-03"],"dc:date.submitted":["May 2014"],"dc:date.updated":["2015-06-08T18:14:37Z"],"dc:description.abstract":["The objective of the proposed research is to advance the power efficiency of wireless neural stimulating systems in inductively powered implantable medical devices (IMD). Several innovative system- and circuit-level techniques are proposed towards the development of power-management circuits and wireless neural stimulating systems with inductive power transmission to improve the overall stimulation power efficiency. Neural stimulating IMDs have been proven as effective therapies to alleviate neurological diseases, while requiring high power and performance for more efficacious treatments. Therefore, power-management circuits and neural stimulators in IMDs should have high power efficiencies to operate with smaller received power from a larger distance. Neural stimulating systems are also required to have high stimulation efficacy for activating the target tissue with a minimum amount of energy, while ensuring charge-balanced stimulation. These features provide several advantages such as a long battery life in an external power transmitter, extended-range inductive power transfer, efficacious and safe stimulation, and less tissue damage from overheating. The proposed research presents several approaches to design and implement the power-efficient wireless neural stimulating IMDs: 1) optimized power-management circuits for inductively powered biomedical microsystems, 2) a power-efficient neural stimulating system with adaptive supply control, and 3) a wireless switched-capacitor stimulation (SCS) system, which is a combination structure of the power-management circuits and neural stimulator, to maximize both stimulator efficiency (before electrodes) and stimulus efficacy (after electrodes)."],"dc:description.degree":["Ph.D."],"dc:embargo.terms":["2015-05-01"],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1853/53449"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.ispartofseries":["Doctor of Philosophy with a Major in Electrical and Computer Engineering"],"dc:relation.orgunit":["5b7adef2-447c-4270-b9fc-846bd76f80f2","7c022d60-21d5-497c-b552-95e489a06569"],"dc:relation.seriesentity":["3890cd56-8ecf-424b-8074-8f5ebd8dbe15"],"dc:subject":["Neural stimulation","Wireless power transfer","Switched-capacitor based stimulator","Implantable medical device","Inductive link","Optogenetics","Tissue modeling"],"dc:title":["A power-efficient wireless neural stimulating system with inductive power transmission"],"dc:type":["Text","Dissertation"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Doctoral"]},"updated_at":"2026-11-19T04:14:06Z"}