{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/53597"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/53597","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Stability of a 24-bus power system with converter interfaced generation","abstract":"The objective of this Masters Thesis is to investigate the system stability implications of integration of power electronic converter interfaced generation (CIG) into conventional power systems. Due to differences between conventional generation and (CIG), the power system fault currents, voltage response, and frequency response will likely change with increased penetration of (CIG). This research has employed state of the art software tools to perform simulations on the IEEE 24-Bus Reliability Test System (RTS-24), appropriately modified to include converter interfaced generation. Time-domain dynamic simulations and fault calculations have been performed for the system. A comprehensive set of simulations has been performed on the base case, comprised entirely of conventional generation. Conventional generation was replaced by (CIG) in the model, one generating station at a time until (CIG) penetration reached one-hundred percent. The comprehensive set of simulations has been performed at each level of (CIG) penetration. The results have been compared to the base case, with a focus on voltage response, frequency response, and fault current levels of the power system.","abstract_html":"The objective of this Masters Thesis is to investigate the system stability implications of integration of power electronic converter interfaced generation (CIG) into conventional power systems. Due to differences between conventional generation and (CIG), the power system fault currents, voltage response, and frequency response will likely change with increased penetration of (CIG). This research has employed state of the art software tools to perform simulations on the IEEE 24-Bus Reliability Test System (RTS-24), appropriately modified to include converter interfaced generation. Time-domain dynamic simulations and fault calculations have been performed for the system. A comprehensive set of simulations has been performed on the base case, comprised entirely of conventional generation. Conventional generation was replaced by (CIG) in the model, one generating station at a time until (CIG) penetration reached one-hundred percent. The comprehensive set of simulations has been performed at each level of (CIG) penetration. The results have been compared to the base case, with a focus on voltage response, frequency response, and fault current levels of the power system.","abstract_has_math":false,"creators":["Weldy, Christopher"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Masters","degree_discipline":null,"degree_department":"Electrical and Computer Engineering","school":null,"contributors":[],"advisors":["Meliopoulos, A. P. Sakis"],"committee_chairs":[],"committee_members":["Saeedifard, Maryam","Taylor, David G."],"year":2015,"date_issued":"2015-04-24","date_published":"2015-04-24","updated_at":"2026-11-19T05:13:53Z","subjects":["Power system stability","Converter interfaced generation"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/53597","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/53597","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F53597","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Meliopoulos, A. P. Sakis"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Saeedifard, Maryam","Taylor, David G."]},{"key":"dc:contributor.department","label":"Department","values":["Electrical and Computer Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["School of Electrical and Computer Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Weldy, Christopher"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2015-06-08T18:40:02Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2015-06-08T18:40:02Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2015-05"]},{"key":"dc:date.issued","label":"Date","values":["2015-04-24"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["May 2015"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2015-06-08T18:40:02Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["e6c102d1-d39c-4d1d-9070-a8743be93cb5"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Master of Science in Electrical and Computer Engineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["5b7adef2-447c-4270-b9fc-846bd76f80f2","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["f8b6e739-0ecd-4831-80cd-4ef4edf0a817"]},{"key":"dc:type","label":"Dc Type","values":["Text","Thesis"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Power system stability","Converter interfaced generation"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/53597"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The objective of this Masters Thesis is to investigate the system stability implications of integration of power electronic converter interfaced generation (CIG) into conventional power systems. Due to differences between conventional generation and (CIG), the power system fault currents, voltage response, and frequency response will likely change with increased penetration of (CIG). This research has employed state of the art software tools to perform simulations on the IEEE 24-Bus Reliability Test System (RTS-24), appropriately modified to include converter interfaced generation. Time-domain dynamic simulations and fault calculations have been performed for the system. A comprehensive set of simulations has been performed on the base case, comprised entirely of conventional generation. Conventional generation was replaced by (CIG) in the model, one generating station at a time until (CIG) penetration reached one-hundred percent. The comprehensive set of simulations has been performed at each level of (CIG) penetration. The results have been compared to the base case, with a focus on voltage response, frequency response, and fault current levels of the power system."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.S."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Stability of a 24-bus power system with converter interfaced generation"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Meliopoulos, A. P. Sakis"],"dc:contributor.committeemember":["Saeedifard, Maryam","Taylor, David G."],"dc:contributor.department":["Electrical and Computer Engineering"],"dc:contributor.other":["School of Electrical and Computer Engineering","College of Engineering"],"dc:creator":["Weldy, Christopher"],"dc:date.accessioned":["2015-06-08T18:40:02Z"],"dc:date.available":["2015-06-08T18:40:02Z"],"dc:date.created":["2015-05"],"dc:date.issued":["2015-04-24"],"dc:date.submitted":["May 2015"],"dc:date.updated":["2015-06-08T18:40:02Z"],"dc:description.abstract":["The objective of this Masters Thesis is to investigate the system stability implications of integration of power electronic converter interfaced generation (CIG) into conventional power systems. Due to differences between conventional generation and (CIG), the power system fault currents, voltage response, and frequency response will likely change with increased penetration of (CIG). This research has employed state of the art software tools to perform simulations on the IEEE 24-Bus Reliability Test System (RTS-24), appropriately modified to include converter interfaced generation. Time-domain dynamic simulations and fault calculations have been performed for the system. A comprehensive set of simulations has been performed on the base case, comprised entirely of conventional generation. Conventional generation was replaced by (CIG) in the model, one generating station at a time until (CIG) penetration reached one-hundred percent. The comprehensive set of simulations has been performed at each level of (CIG) penetration. The results have been compared to the base case, with a focus on voltage response, frequency response, and fault current levels of the power system."],"dc:description.degree":["M.S."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1853/53597"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["e6c102d1-d39c-4d1d-9070-a8743be93cb5"],"dc:relation.ispartofseries":["Master of Science in Electrical and Computer Engineering"],"dc:relation.orgunit":["5b7adef2-447c-4270-b9fc-846bd76f80f2","7c022d60-21d5-497c-b552-95e489a06569"],"dc:relation.seriesentity":["f8b6e739-0ecd-4831-80cd-4ef4edf0a817"],"dc:subject":["Power system stability","Converter interfaced generation"],"dc:title":["Stability of a 24-bus power system with converter interfaced generation"],"dc:type":["Text","Thesis"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Masters"]},"updated_at":"2026-11-19T05:13:53Z"}