{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/54009"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/54009","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"An inductively powered multichannel wireless implantable neural recording system (WINeR)","abstract":"A multi-channel wireless implantable neural recording (WINeR) system for electrophysiology and behavioral neuroscience research applications was proposed. The system is composed of two units: a system-on-a-chip (SoC) transmitter (Tx) unit and a receiver (Rx) unit. In the Tx unit, the outputs are combined with marker signals and modulated into pulse widths after the neural signals are amplified and filtered by an array of low-noise amplifiers (LNA). The next step involves time-division multiplexing (TDM) of pulse-width modulation (PWM) signals. The TDM-PWM signal drives RF transmitter block and is transmitted by an antenna. To satisfy the needs of neuroscientists during animal experiments, the proposed WINeR system provides long-term recording with inductive powering and stimulus-artifact rejection for closed-loop operations, which requires simultaneous stimulation and recording. The Rx is another critical unit for wireless-link communication. To increase the area of wireless coverage, multiple antennas are used for the Rx. In addition, the automatic frequency-tracking method is used to track free-running Tx frequencies, and a smart time-to-digital conversion method is used to reduce noise and interference. A high-throughput computer interface and software are also developed to continuously receive and store neural data. The WINeR system is a potential tool for neuroscientists due to several advantages, such as a reliable wireless link with large coverage and no blind spots, low power consumption, an unlimited power source, and a stimulation function.","abstract_html":"A multi-channel wireless implantable neural recording (WINeR) system for electrophysiology and behavioral neuroscience research applications was proposed. The system is composed of two units: a system-on-a-chip (SoC) transmitter (Tx) unit and a receiver (Rx) unit. In the Tx unit, the outputs are combined with marker signals and modulated into pulse widths after the neural signals are amplified and filtered by an array of low-noise amplifiers (LNA). The next step involves time-division multiplexing (TDM) of pulse-width modulation (PWM) signals. The TDM-PWM signal drives RF transmitter block and is transmitted by an antenna. To satisfy the needs of neuroscientists during animal experiments, the proposed WINeR system provides long-term recording with inductive powering and stimulus-artifact rejection for closed-loop operations, which requires simultaneous stimulation and recording. The Rx is another critical unit for wireless-link communication. To increase the area of wireless coverage, multiple antennas are used for the Rx. In addition, the automatic frequency-tracking method is used to track free-running Tx frequencies, and a smart time-to-digital conversion method is used to reduce noise and interference. A high-throughput computer interface and software are also developed to continuously receive and store neural data. The WINeR system is a potential tool for neuroscientists due to several advantages, such as a reliable wireless link with large coverage and no blind spots, low power consumption, an unlimited power source, and a stimulation function.","abstract_has_math":false,"creators":["Lee, Seung Bae"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Doctoral","degree_discipline":null,"degree_department":"Electrical and Computer Engineering","school":null,"contributors":[],"advisors":["Ghovanloo, Maysam"],"committee_chairs":[],"committee_members":["Bhatti, Pamela","Papapolymerou, John","Scott, Waymond","Manns, Joseph"],"year":2014,"date_issued":"2014-06-20","date_published":"2014-06-20","updated_at":"2026-11-19T05:01:10Z","subjects":["Neural recording","Implantable device","Circuit technique"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/54009","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/54009","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F54009","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Ghovanloo, Maysam"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Bhatti, Pamela","Papapolymerou, John","Scott, Waymond","Manns, Joseph"]},{"key":"dc:contributor.department","label":"Department","values":["Electrical and Computer Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["School of Electrical and Computer Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Lee, Seung Bae"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2015-09-21T15:52:29Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2015-09-22T05:30:06Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2014-08"]},{"key":"dc:date.issued","label":"Date","values":["2014-06-20"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["August 2014"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2015-09-21T15:52:29Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Doctor of Philosophy with a Major in Electrical and Computer Engineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["5b7adef2-447c-4270-b9fc-846bd76f80f2","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["3890cd56-8ecf-424b-8074-8f5ebd8dbe15"]},{"key":"dc:type","label":"Dc Type","values":["Text","Dissertation"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctoral"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Neural recording","Implantable device","Circuit technique"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/54009"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A multi-channel wireless implantable neural recording (WINeR) system for electrophysiology and behavioral neuroscience research applications was proposed. The system is composed of two units: a system-on-a-chip (SoC) transmitter (Tx) unit and a receiver (Rx) unit. In the Tx unit, the outputs are combined with marker signals and modulated into pulse widths after the neural signals are amplified and filtered by an array of low-noise amplifiers (LNA). The next step involves time-division multiplexing (TDM) of pulse-width modulation (PWM) signals. The TDM-PWM signal drives RF transmitter block and is transmitted by an antenna. To satisfy the needs of neuroscientists during animal experiments, the proposed WINeR system provides long-term recording with inductive powering and stimulus-artifact rejection for closed-loop operations, which requires simultaneous stimulation and recording. The Rx is another critical unit for wireless-link communication. To increase the area of wireless coverage, multiple antennas are used for the Rx. In addition, the automatic frequency-tracking method is used to track free-running Tx frequencies, and a smart time-to-digital conversion method is used to reduce noise and interference. A high-throughput computer interface and software are also developed to continuously receive and store neural data. The WINeR system is a potential tool for neuroscientists due to several advantages, such as a reliable wireless link with large coverage and no blind spots, low power consumption, an unlimited power source, and a stimulation function."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph.D."]},{"key":"dc:embargo.terms","label":"Dc Embargo Terms","values":["2015-08-01"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["An inductively powered multichannel wireless implantable neural recording system (WINeR)"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Ghovanloo, Maysam"],"dc:contributor.committeemember":["Bhatti, Pamela","Papapolymerou, John","Scott, Waymond","Manns, Joseph"],"dc:contributor.department":["Electrical and Computer Engineering"],"dc:contributor.other":["School of Electrical and Computer Engineering","College of Engineering"],"dc:creator":["Lee, Seung Bae"],"dc:date.accessioned":["2015-09-21T15:52:29Z"],"dc:date.available":["2015-09-22T05:30:06Z"],"dc:date.created":["2014-08"],"dc:date.issued":["2014-06-20"],"dc:date.submitted":["August 2014"],"dc:date.updated":["2015-09-21T15:52:29Z"],"dc:description.abstract":["A multi-channel wireless implantable neural recording (WINeR) system for electrophysiology and behavioral neuroscience research applications was proposed. The system is composed of two units: a system-on-a-chip (SoC) transmitter (Tx) unit and a receiver (Rx) unit. In the Tx unit, the outputs are combined with marker signals and modulated into pulse widths after the neural signals are amplified and filtered by an array of low-noise amplifiers (LNA). The next step involves time-division multiplexing (TDM) of pulse-width modulation (PWM) signals. The TDM-PWM signal drives RF transmitter block and is transmitted by an antenna. To satisfy the needs of neuroscientists during animal experiments, the proposed WINeR system provides long-term recording with inductive powering and stimulus-artifact rejection for closed-loop operations, which requires simultaneous stimulation and recording. The Rx is another critical unit for wireless-link communication. To increase the area of wireless coverage, multiple antennas are used for the Rx. In addition, the automatic frequency-tracking method is used to track free-running Tx frequencies, and a smart time-to-digital conversion method is used to reduce noise and interference. A high-throughput computer interface and software are also developed to continuously receive and store neural data. The WINeR system is a potential tool for neuroscientists due to several advantages, such as a reliable wireless link with large coverage and no blind spots, low power consumption, an unlimited power source, and a stimulation function."],"dc:description.degree":["Ph.D."],"dc:embargo.terms":["2015-08-01"],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1853/54009"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.ispartofseries":["Doctor of Philosophy with a Major in Electrical and Computer Engineering"],"dc:relation.orgunit":["5b7adef2-447c-4270-b9fc-846bd76f80f2","7c022d60-21d5-497c-b552-95e489a06569"],"dc:relation.seriesentity":["3890cd56-8ecf-424b-8074-8f5ebd8dbe15"],"dc:subject":["Neural recording","Implantable device","Circuit technique"],"dc:title":["An inductively powered multichannel wireless implantable neural recording system (WINeR)"],"dc:type":["Text","Dissertation"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Doctoral"]},"updated_at":"2026-11-19T05:01:10Z"}