{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/54018"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/54018","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Design of a low-power interface circuitry for a vestibular prosthesis system","abstract":"The human vestibular system is responsible for maintaining balance and orientation, and stabilizing gaze during head motion. Head motion is sensed by vestibular sensors and encoded via the firing rate of vestibular neurons. Vestibular disorders can result in dizziness, imbalance, and disequilibrium. Currently there are no therapeutic options for individuals suffering from bilateral vestibular dysfunction. A potential solution is a vestibular prosthesis (VP). This device serves to replace peripheral vestibular organs by sensing angular motion, detected by semicircular canals (SCCs), and linear head motion, detected by the otolith organs, and selectively stimulating the corresponding vestibular afferents. An ideal VP will not only mimic the patient-dependent vestibular neural dynamics, but also consume low power. In this study, three energy-efficient ways to implement the motion encoding function required in a vestibular prosthesis are presented. Both analog and digital signal processing techniques to implement the vestibular signal processing functions are investigated.","abstract_html":"The human vestibular system is responsible for maintaining balance and orientation, and stabilizing gaze during head motion. Head motion is sensed by vestibular sensors and encoded via the firing rate of vestibular neurons. Vestibular disorders can result in dizziness, imbalance, and disequilibrium. Currently there are no therapeutic options for individuals suffering from bilateral vestibular dysfunction. A potential solution is a vestibular prosthesis (VP). This device serves to replace peripheral vestibular organs by sensing angular motion, detected by semicircular canals (SCCs), and linear head motion, detected by the otolith organs, and selectively stimulating the corresponding vestibular afferents. An ideal VP will not only mimic the patient-dependent vestibular neural dynamics, but also consume low power. In this study, three energy-efficient ways to implement the motion encoding function required in a vestibular prosthesis are presented. Both analog and digital signal processing techniques to implement the vestibular signal processing functions are investigated.","abstract_has_math":false,"creators":["Toreyin, Hakan"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Doctoral","degree_discipline":null,"degree_department":"Electrical and Computer Engineering","school":null,"contributors":[],"advisors":["Bhatti, Pamela T."],"committee_chairs":[],"committee_members":["Anderson, David V.","Butera, Robert J.","Inan, Omer T.","Gore, Russell K."],"year":2014,"date_issued":"2014-06-27","date_published":"2014-06-27","updated_at":"2026-11-19T05:52:06Z","subjects":["Vestibular prosthesis ASIC","Analog signal processing"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/54018","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/54018","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F54018","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Bhatti, Pamela T."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Anderson, David V.","Butera, Robert J.","Inan, Omer T.","Gore, Russell K."]},{"key":"dc:contributor.department","label":"Department","values":["Electrical and Computer Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["School of Electrical and Computer Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Toreyin, Hakan"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2015-09-21T15:52:49Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2015-09-22T05:30:06Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2014-08"]},{"key":"dc:date.issued","label":"Date","values":["2014-06-27"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["August 2014"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2015-09-21T15:52:49Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["de58a4f5-0f0d-4a2c-91f6-bae53faf8e56"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["5b7adef2-447c-4270-b9fc-846bd76f80f2","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:type","label":"Dc Type","values":["Text","Dissertation"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctoral"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Vestibular prosthesis ASIC","Analog signal processing"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/54018"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The human vestibular system is responsible for maintaining balance and orientation, and stabilizing gaze during head motion. Head motion is sensed by vestibular sensors and encoded via the firing rate of vestibular neurons. Vestibular disorders can result in dizziness, imbalance, and disequilibrium. Currently there are no therapeutic options for individuals suffering from bilateral vestibular dysfunction. A potential solution is a vestibular prosthesis (VP). This device serves to replace peripheral vestibular organs by sensing angular motion, detected by semicircular canals (SCCs), and linear head motion, detected by the otolith organs, and selectively stimulating the corresponding vestibular afferents. An ideal VP will not only mimic the patient-dependent vestibular neural dynamics, but also consume low power. In this study, three energy-efficient ways to implement the motion encoding function required in a vestibular prosthesis are presented. Both analog and digital signal processing techniques to implement the vestibular signal processing functions are investigated."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph.D."]},{"key":"dc:embargo.terms","label":"Dc Embargo Terms","values":["2015-08-01"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Design of a low-power interface circuitry for a vestibular prosthesis system"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Bhatti, Pamela T."],"dc:contributor.committeemember":["Anderson, David V.","Butera, Robert J.","Inan, Omer T.","Gore, Russell K."],"dc:contributor.department":["Electrical and Computer Engineering"],"dc:contributor.other":["School of Electrical and Computer Engineering","College of Engineering"],"dc:creator":["Toreyin, Hakan"],"dc:date.accessioned":["2015-09-21T15:52:49Z"],"dc:date.available":["2015-09-22T05:30:06Z"],"dc:date.created":["2014-08"],"dc:date.issued":["2014-06-27"],"dc:date.submitted":["August 2014"],"dc:date.updated":["2015-09-21T15:52:49Z"],"dc:description.abstract":["The human vestibular system is responsible for maintaining balance and orientation, and stabilizing gaze during head motion. Head motion is sensed by vestibular sensors and encoded via the firing rate of vestibular neurons. Vestibular disorders can result in dizziness, imbalance, and disequilibrium. Currently there are no therapeutic options for individuals suffering from bilateral vestibular dysfunction. A potential solution is a vestibular prosthesis (VP). This device serves to replace peripheral vestibular organs by sensing angular motion, detected by semicircular canals (SCCs), and linear head motion, detected by the otolith organs, and selectively stimulating the corresponding vestibular afferents. An ideal VP will not only mimic the patient-dependent vestibular neural dynamics, but also consume low power. In this study, three energy-efficient ways to implement the motion encoding function required in a vestibular prosthesis are presented. Both analog and digital signal processing techniques to implement the vestibular signal processing functions are investigated."],"dc:description.degree":["Ph.D."],"dc:embargo.terms":["2015-08-01"],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1853/54018"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["de58a4f5-0f0d-4a2c-91f6-bae53faf8e56"],"dc:relation.orgunit":["5b7adef2-447c-4270-b9fc-846bd76f80f2","7c022d60-21d5-497c-b552-95e489a06569"],"dc:subject":["Vestibular prosthesis ASIC","Analog signal processing"],"dc:title":["Design of a low-power interface circuitry for a vestibular prosthesis system"],"dc:type":["Text","Dissertation"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Doctoral"]},"updated_at":"2026-11-19T05:52:06Z"}