{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/54303"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/54303","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Modeling and optimization of capacitive micromachined ultrasonic transducers","abstract":"The objective of this research is to develop large signal modeling and optimization methods for Capacitive Micromachined Ultrasonic Transducers (CMUTs), especially when they are used in an array configuration. General modeling and optimization methods that cover a large domain of CMUT designs are crucial, as many membrane and array geometry combinations are possible using existing microfabrication technologies. Currently, large signal modeling methods for CMUTs are not well established and nonlinear imaging techniques utilizing linear piezoelectric transducers are not applicable to CMUTs because of their strong nonlinearity. In this work, the nonlinear CMUT behavior is studied, and a feedback linearization method is proposed to reduce the CMUT nonlinearity. This method is shown to improve the CMUT performance for continuous wave applications, such as high-intensity focused ultrasound or harmonic imaging, where transducer linearity is crucial. In the second part of this dissertation, a large signal model is developed that is capable of transient modeling of CMUT arrays with arbitrary electrical terminations. The developed model is suitable for iterative design optimization of CMUTs and CMUT based imaging systems with arbitrary membrane and array geometries for a variety of applications. Finally, a novel multi-pulse method for nonlinear tissue and contrast agent imaging with CMUTs is presented. It is shown that the nonlinear content can be successfully extracted from echo signals in a CMUT based imaging system using a multiple pulse scheme. The proposed method is independent of the CMUT geometry and valid for large signal operation. Experimental results verifying the developed large signal CMUT array model, proposed gap feedback and multi-pulse techniques are also presented.","abstract_html":"The objective of this research is to develop large signal modeling and optimization methods for Capacitive Micromachined Ultrasonic Transducers (CMUTs), especially when they are used in an array configuration. General modeling and optimization methods that cover a large domain of CMUT designs are crucial, as many membrane and array geometry combinations are possible using existing microfabrication technologies. Currently, large signal modeling methods for CMUTs are not well established and nonlinear imaging techniques utilizing linear piezoelectric transducers are not applicable to CMUTs because of their strong nonlinearity. In this work, the nonlinear CMUT behavior is studied, and a feedback linearization method is proposed to reduce the CMUT nonlinearity. This method is shown to improve the CMUT performance for continuous wave applications, such as high-intensity focused ultrasound or harmonic imaging, where transducer linearity is crucial. In the second part of this dissertation, a large signal model is developed that is capable of transient modeling of CMUT arrays with arbitrary electrical terminations. The developed model is suitable for iterative design optimization of CMUTs and CMUT based imaging systems with arbitrary membrane and array geometries for a variety of applications. Finally, a novel multi-pulse method for nonlinear tissue and contrast agent imaging with CMUTs is presented. It is shown that the nonlinear content can be successfully extracted from echo signals in a CMUT based imaging system using a multiple pulse scheme. The proposed method is independent of the CMUT geometry and valid for large signal operation. Experimental results verifying the developed large signal CMUT array model, proposed gap feedback and multi-pulse techniques are also presented.","abstract_has_math":false,"creators":["Satir, Sarp"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Doctoral","degree_discipline":null,"degree_department":"Electrical and Computer Engineering","school":null,"contributors":[],"advisors":["Degertekin, F. Levent"],"committee_chairs":[],"committee_members":["Brand, Oliver","Sabra, Karim","Ghovanloo, Maysam","Bhatti, Pamela"],"year":2014,"date_issued":"2014-11-17","date_published":"2014-11-17","updated_at":"2026-11-19T04:53:54Z","subjects":["CMUTs","Ultrasound imaging","Nonlinear modeling"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/54303","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/54303","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F54303","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Degertekin, F. Levent"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Brand, Oliver","Sabra, Karim","Ghovanloo, Maysam","Bhatti, Pamela"]},{"key":"dc:contributor.department","label":"Department","values":["Electrical and Computer Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["School of Electrical and Computer Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Satir, Sarp"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2016-01-07T17:22:04Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2016-01-07T17:22:04Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2014-12"]},{"key":"dc:date.issued","label":"Date","values":["2014-11-17"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["December 2014"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2016-01-07T17:22:04Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["9afd92fe-bb98-4c83-b8ac-fc596320991a"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Doctor of Philosophy with a Major in Electrical and Computer Engineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["5b7adef2-447c-4270-b9fc-846bd76f80f2","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["3890cd56-8ecf-424b-8074-8f5ebd8dbe15"]},{"key":"dc:type","label":"Dc Type","values":["Text","Dissertation"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctoral"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["CMUTs","Ultrasound imaging","Nonlinear modeling"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/54303"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The objective of this research is to develop large signal modeling and optimization methods for Capacitive Micromachined Ultrasonic Transducers (CMUTs), especially when they are used in an array configuration. General modeling and optimization methods that cover a large domain of CMUT designs are crucial, as many membrane and array geometry combinations are possible using existing microfabrication technologies. Currently, large signal modeling methods for CMUTs are not well established and nonlinear imaging techniques utilizing linear piezoelectric transducers are not applicable to CMUTs because of their strong nonlinearity. In this work, the nonlinear CMUT behavior is studied, and a feedback linearization method is proposed to reduce the CMUT nonlinearity. This method is shown to improve the CMUT performance for continuous wave applications, such as high-intensity focused ultrasound or harmonic imaging, where transducer linearity is crucial. In the second part of this dissertation, a large signal model is developed that is capable of transient modeling of CMUT arrays with arbitrary electrical terminations. The developed model is suitable for iterative design optimization of CMUTs and CMUT based imaging systems with arbitrary membrane and array geometries for a variety of applications. Finally, a novel multi-pulse method for nonlinear tissue and contrast agent imaging with CMUTs is presented. It is shown that the nonlinear content can be successfully extracted from echo signals in a CMUT based imaging system using a multiple pulse scheme. The proposed method is independent of the CMUT geometry and valid for large signal operation. Experimental results verifying the developed large signal CMUT array model, proposed gap feedback and multi-pulse techniques are also presented."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph.D."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Modeling and optimization of capacitive micromachined ultrasonic transducers"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Degertekin, F. Levent"],"dc:contributor.committeemember":["Brand, Oliver","Sabra, Karim","Ghovanloo, Maysam","Bhatti, Pamela"],"dc:contributor.department":["Electrical and Computer Engineering"],"dc:contributor.other":["School of Electrical and Computer Engineering","College of Engineering"],"dc:creator":["Satir, Sarp"],"dc:date.accessioned":["2016-01-07T17:22:04Z"],"dc:date.available":["2016-01-07T17:22:04Z"],"dc:date.created":["2014-12"],"dc:date.issued":["2014-11-17"],"dc:date.submitted":["December 2014"],"dc:date.updated":["2016-01-07T17:22:04Z"],"dc:description.abstract":["The objective of this research is to develop large signal modeling and optimization methods for Capacitive Micromachined Ultrasonic Transducers (CMUTs), especially when they are used in an array configuration. General modeling and optimization methods that cover a large domain of CMUT designs are crucial, as many membrane and array geometry combinations are possible using existing microfabrication technologies. Currently, large signal modeling methods for CMUTs are not well established and nonlinear imaging techniques utilizing linear piezoelectric transducers are not applicable to CMUTs because of their strong nonlinearity. In this work, the nonlinear CMUT behavior is studied, and a feedback linearization method is proposed to reduce the CMUT nonlinearity. This method is shown to improve the CMUT performance for continuous wave applications, such as high-intensity focused ultrasound or harmonic imaging, where transducer linearity is crucial. In the second part of this dissertation, a large signal model is developed that is capable of transient modeling of CMUT arrays with arbitrary electrical terminations. The developed model is suitable for iterative design optimization of CMUTs and CMUT based imaging systems with arbitrary membrane and array geometries for a variety of applications. Finally, a novel multi-pulse method for nonlinear tissue and contrast agent imaging with CMUTs is presented. It is shown that the nonlinear content can be successfully extracted from echo signals in a CMUT based imaging system using a multiple pulse scheme. The proposed method is independent of the CMUT geometry and valid for large signal operation. Experimental results verifying the developed large signal CMUT array model, proposed gap feedback and multi-pulse techniques are also presented."],"dc:description.degree":["Ph.D."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1853/54303"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["9afd92fe-bb98-4c83-b8ac-fc596320991a"],"dc:relation.ispartofseries":["Doctor of Philosophy with a Major in Electrical and Computer Engineering"],"dc:relation.orgunit":["5b7adef2-447c-4270-b9fc-846bd76f80f2","7c022d60-21d5-497c-b552-95e489a06569"],"dc:relation.seriesentity":["3890cd56-8ecf-424b-8074-8f5ebd8dbe15"],"dc:subject":["CMUTs","Ultrasound imaging","Nonlinear modeling"],"dc:title":["Modeling and optimization of capacitive micromachined ultrasonic transducers"],"dc:type":["Text","Dissertation"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Doctoral"]},"updated_at":"2026-11-19T04:53:54Z"}