{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/54464"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/54464","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Cherenkov detectors for transmission studies of monoenergetic high-energy photons in active interrogation applications","abstract":"Active interrogation of cargo containers employing monoenergetic photons offers an expeditious low-dose approach in pursuit of shielded special nuclear materials. Cherenkov detectors can be used for a variety of purposes, including imaging of the cargo contingent upon gamma ray energies used in interrogation. If the gamma ray energies are sufficiently well separated, as the case in $^{11}$B(d,n-$\\gamma$)$^{12}$C reaction resulting in 4.4 MeV and 15.1 MeV photons, spectral analysis using Cherenkov detectors is possible. Applying an array of custom designed Cherenkov detectors reduce undesired low energy background, both natural and scatter from the application environment, while producing the capability of high contrast transmission imaging. Spectral analysis of the image can be used to confirm the presence of high-Z materials by analyzing the relative transmission of the two main energies emitted by exploiting the large difference in Compton Scatter and pair production cross sections. These detectors require a special approach to design and energy calibration due to the lack of resolution in order for spectral analysis to take place. This thesis addresses the design and utility of Cherenkov detectors for active interrogation with monoenergetic photons as well as the results of computational and experimental studies of their energy calibration and application to imaging with material identification.","abstract_html":"Active interrogation of cargo containers employing monoenergetic photons offers an expeditious low-dose approach in pursuit of shielded special nuclear materials. Cherenkov detectors can be used for a variety of purposes, including imaging of the cargo contingent upon gamma ray energies used in interrogation. If the gamma ray energies are sufficiently well separated, as the case in <span class=\"etd-inline-math\"><sup>11</sup></span>B(d,n-<span class=\"etd-inline-math\">&gamma;</span>)<span class=\"etd-inline-math\"><sup>12</sup></span>C reaction resulting in 4.4 MeV and 15.1 MeV photons, spectral analysis using Cherenkov detectors is possible. Applying an array of custom designed Cherenkov detectors reduce undesired low energy background, both natural and scatter from the application environment, while producing the capability of high contrast transmission imaging. Spectral analysis of the image can be used to confirm the presence of high-Z materials by analyzing the relative transmission of the two main energies emitted by exploiting the large difference in Compton Scatter and pair production cross sections. These detectors require a special approach to design and energy calibration due to the lack of resolution in order for spectral analysis to take place. This thesis addresses the design and utility of Cherenkov detectors for active interrogation with monoenergetic photons as well as the results of computational and experimental studies of their energy calibration and application to imaging with material identification.","abstract_has_math":true,"creators":["Rose, Paul B."],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Masters","degree_discipline":null,"degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["Erickson, Anna S."],"committee_chairs":[],"committee_members":["Hertel, Nolan E.","Wang, Chris K."],"year":2015,"date_issued":"2015-12-03","date_published":"2015-12-03","updated_at":"2026-11-19T05:11:40Z","subjects":["Cherenkov","Active interrogation"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/54464","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/54464","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F54464","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Erickson, Anna S."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Hertel, Nolan E.","Wang, Chris K."]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["George W. Woodruff School of Mechanical Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Rose, Paul B."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2016-01-07T17:40:34Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2016-01-07T17:40:34Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2015-12"]},{"key":"dc:date.issued","label":"Date","values":["2015-12-03"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["December 2015"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2016-01-07T17:40:34Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["df2e2349-4cf3-4d53-89e5-adc9b56c9ac6"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["c01ff908-c25f-439b-bf10-a074ed886bb7","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:type","label":"Dc Type","values":["Text","Thesis"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Cherenkov","Active interrogation"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/54464"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Active interrogation of cargo containers employing monoenergetic photons offers an expeditious low-dose approach in pursuit of shielded special nuclear materials. Cherenkov detectors can be used for a variety of purposes, including imaging of the cargo contingent upon gamma ray energies used in interrogation. If the gamma ray energies are sufficiently well separated, as the case in $^{11}$B(d,n-$\\gamma$)$^{12}$C reaction resulting in 4.4 MeV and 15.1 MeV photons, spectral analysis using Cherenkov detectors is possible. Applying an array of custom designed Cherenkov detectors reduce undesired low energy background, both natural and scatter from the application environment, while producing the capability of high contrast transmission imaging. Spectral analysis of the image can be used to confirm the presence of high-Z materials by analyzing the relative transmission of the two main energies emitted by exploiting the large difference in Compton Scatter and pair production cross sections. These detectors require a special approach to design and energy calibration due to the lack of resolution in order for spectral analysis to take place. This thesis addresses the design and utility of Cherenkov detectors for active interrogation with monoenergetic photons as well as the results of computational and experimental studies of their energy calibration and application to imaging with material identification."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.S."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Cherenkov detectors for transmission studies of monoenergetic high-energy photons in active interrogation applications"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Erickson, Anna S."],"dc:contributor.committeemember":["Hertel, Nolan E.","Wang, Chris K."],"dc:contributor.department":["Mechanical Engineering"],"dc:contributor.other":["George W. Woodruff School of Mechanical Engineering","College of Engineering"],"dc:creator":["Rose, Paul B."],"dc:date.accessioned":["2016-01-07T17:40:34Z"],"dc:date.available":["2016-01-07T17:40:34Z"],"dc:date.created":["2015-12"],"dc:date.issued":["2015-12-03"],"dc:date.submitted":["December 2015"],"dc:date.updated":["2016-01-07T17:40:34Z"],"dc:description.abstract":["Active interrogation of cargo containers employing monoenergetic photons offers an expeditious low-dose approach in pursuit of shielded special nuclear materials. Cherenkov detectors can be used for a variety of purposes, including imaging of the cargo contingent upon gamma ray energies used in interrogation. If the gamma ray energies are sufficiently well separated, as the case in $^{11}$B(d,n-$\\gamma$)$^{12}$C reaction resulting in 4.4 MeV and 15.1 MeV photons, spectral analysis using Cherenkov detectors is possible. Applying an array of custom designed Cherenkov detectors reduce undesired low energy background, both natural and scatter from the application environment, while producing the capability of high contrast transmission imaging. Spectral analysis of the image can be used to confirm the presence of high-Z materials by analyzing the relative transmission of the two main energies emitted by exploiting the large difference in Compton Scatter and pair production cross sections. These detectors require a special approach to design and energy calibration due to the lack of resolution in order for spectral analysis to take place. This thesis addresses the design and utility of Cherenkov detectors for active interrogation with monoenergetic photons as well as the results of computational and experimental studies of their energy calibration and application to imaging with material identification."],"dc:description.degree":["M.S."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1853/54464"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["df2e2349-4cf3-4d53-89e5-adc9b56c9ac6"],"dc:relation.orgunit":["c01ff908-c25f-439b-bf10-a074ed886bb7","7c022d60-21d5-497c-b552-95e489a06569"],"dc:subject":["Cherenkov","Active interrogation"],"dc:title":["Cherenkov detectors for transmission studies of monoenergetic high-energy photons in active interrogation applications"],"dc:type":["Text","Thesis"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Masters"]},"updated_at":"2026-11-19T05:11:40Z"}