{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/54908"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/54908","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Advanced optical microscopy for three dimensional deformation, profile and tomography measurement","abstract":"Deformation, profile and tomography measurement is critical for engineering materials characterization and engineering structure component design, analysis and biomedical application. The current existing 3D measurement method, such as stylus based profilometry, 3D optical stereo imaging and focus stacking, either suffers from low sampling speed from spatial scanning or maximum thickness of the specimen that could be imaged due to physical constraints. This thesis is dedicated to develop a hybrid 3D measurement method that can be easily implemented with fast imaging speed for dynamic process at the microscale. Also, at the microscale, the reduced depth of focus of existing microscope system greatly limits the maximum depth of the specimen that could be imaged, especially at high magnification. In this study, a 3D tomography system will be developed with extended depth of focus and improved axial resolution.","abstract_html":"Deformation, profile and tomography measurement is critical for engineering materials characterization and engineering structure component design, analysis and biomedical application. The current existing 3D measurement method, such as stylus based profilometry, 3D optical stereo imaging and focus stacking, either suffers from low sampling speed from spatial scanning or maximum thickness of the specimen that could be imaged due to physical constraints. This thesis is dedicated to develop a hybrid 3D measurement method that can be easily implemented with fast imaging speed for dynamic process at the microscale. Also, at the microscale, the reduced depth of focus of existing microscope system greatly limits the maximum depth of the specimen that could be imaged, especially at high magnification. In this study, a 3D tomography system will be developed with extended depth of focus and improved axial resolution.","abstract_has_math":false,"creators":["Pan, Zhipeng"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Masters","degree_discipline":null,"degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["Xia, Shuman"],"committee_chairs":[],"committee_members":["Zhou, Min","Zhu, Lei"],"year":2016,"date_issued":"2016-05-27","date_published":"2016-05-27","updated_at":"2026-11-19T04:13:11Z","subjects":["3D microscopy","Deformation"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/54908","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/54908","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F54908","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Xia, Shuman"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Zhou, Min","Zhu, Lei"]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["George W. Woodruff School of Mechanical Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Pan, Zhipeng"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2016-05-27T13:11:07Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2016-05-27T13:11:07Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2016-05"]},{"key":"dc:date.issued","label":"Date","values":["2016-05-27"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["May 2016"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2016-05-27T13:11:07Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["07c86dc7-f7f6-4af7-882e-181402c65cd8"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["c01ff908-c25f-439b-bf10-a074ed886bb7","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:type","label":"Dc Type","values":["Text","Thesis"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["3D microscopy","Deformation"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/54908"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Deformation, profile and tomography measurement is critical for engineering materials characterization and engineering structure component design, analysis and biomedical application. The current existing 3D measurement method, such as stylus based profilometry, 3D optical stereo imaging and focus stacking, either suffers from low sampling speed from spatial scanning or maximum thickness of the specimen that could be imaged due to physical constraints. This thesis is dedicated to develop a hybrid 3D measurement method that can be easily implemented with fast imaging speed for dynamic process at the microscale. Also, at the microscale, the reduced depth of focus of existing microscope system greatly limits the maximum depth of the specimen that could be imaged, especially at high magnification. In this study, a 3D tomography system will be developed with extended depth of focus and improved axial resolution."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.S."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Advanced optical microscopy for three dimensional deformation, profile and tomography measurement"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Xia, Shuman"],"dc:contributor.committeemember":["Zhou, Min","Zhu, Lei"],"dc:contributor.department":["Mechanical Engineering"],"dc:contributor.other":["George W. Woodruff School of Mechanical Engineering","College of Engineering"],"dc:creator":["Pan, Zhipeng"],"dc:date.accessioned":["2016-05-27T13:11:07Z"],"dc:date.available":["2016-05-27T13:11:07Z"],"dc:date.created":["2016-05"],"dc:date.issued":["2016-05-27"],"dc:date.submitted":["May 2016"],"dc:date.updated":["2016-05-27T13:11:07Z"],"dc:description.abstract":["Deformation, profile and tomography measurement is critical for engineering materials characterization and engineering structure component design, analysis and biomedical application. The current existing 3D measurement method, such as stylus based profilometry, 3D optical stereo imaging and focus stacking, either suffers from low sampling speed from spatial scanning or maximum thickness of the specimen that could be imaged due to physical constraints. This thesis is dedicated to develop a hybrid 3D measurement method that can be easily implemented with fast imaging speed for dynamic process at the microscale. Also, at the microscale, the reduced depth of focus of existing microscope system greatly limits the maximum depth of the specimen that could be imaged, especially at high magnification. In this study, a 3D tomography system will be developed with extended depth of focus and improved axial resolution."],"dc:description.degree":["M.S."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1853/54908"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["07c86dc7-f7f6-4af7-882e-181402c65cd8"],"dc:relation.orgunit":["c01ff908-c25f-439b-bf10-a074ed886bb7","7c022d60-21d5-497c-b552-95e489a06569"],"dc:subject":["3D microscopy","Deformation"],"dc:title":["Advanced optical microscopy for three dimensional deformation, profile and tomography measurement"],"dc:type":["Text","Thesis"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Masters"]},"updated_at":"2026-11-19T04:13:11Z"}