{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/55003"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/55003","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Secondary prompt gamma-rays to improve proton range verification","abstract":"The goal of this research is to evaluate the secondary prompt gamma (PG) yield from proton therapy at high characteristic energies from MC model simulations and experimental data. Recent studies indicate that target composition influences PG characteristic energy and yield, and the quantification of PG may be used to offer real-time dose verification for proton therapy. In this study PG analysis was performed for MC simulations to evaluate the characteristic measurements and total yield of secondary PG emitted from a target in the 0-8 MeV range from a proton therapy beam over a range of four different beam energies (70 MeV, 160 MeV, 200 MeV, 220 MeV). This was repeated in several target materials (carbon, calcium oxide, calcium fluoride, PMMA, and HDPE) in order to evaluate the influence of the incident energy and the target material on the PG yield and energy spectra. PG energy spectra determined from the specified target materials indicated that the 3.74 MeV energy peak shows a linear correlation between PG intensity and calcium mass fraction of the target material. 6.13 MeV and 4.44 MeV energy peak are not unique to the respective, oxygen and combined oxygen and carbon, mass fraction of the target material. This relationship is complicated by the addition of calcium within the target. Experimental data was collected in order to validate the computational model based on comparison of relative characteristic energy peek intensities. The relative peak ratio determined from experimental data is in good agreement with model prediction, the combined peak ratio is within 0.2%.","abstract_html":"The goal of this research is to evaluate the secondary prompt gamma (PG) yield from proton therapy at high characteristic energies from MC model simulations and experimental data. Recent studies indicate that target composition influences PG characteristic energy and yield, and the quantification of PG may be used to offer real-time dose verification for proton therapy. In this study PG analysis was performed for MC simulations to evaluate the characteristic measurements and total yield of secondary PG emitted from a target in the 0-8 MeV range from a proton therapy beam over a range of four different beam energies (70 MeV, 160 MeV, 200 MeV, 220 MeV). This was repeated in several target materials (carbon, calcium oxide, calcium fluoride, PMMA, and HDPE) in order to evaluate the influence of the incident energy and the target material on the PG yield and energy spectra. PG energy spectra determined from the specified target materials indicated that the 3.74 MeV energy peak shows a linear correlation between PG intensity and calcium mass fraction of the target material. 6.13 MeV and 4.44 MeV energy peak are not unique to the respective, oxygen and combined oxygen and carbon, mass fraction of the target material. This relationship is complicated by the addition of calcium within the target. Experimental data was collected in order to validate the computational model based on comparison of relative characteristic energy peek intensities. The relative peak ratio determined from experimental data is in good agreement with model prediction, the combined peak ratio is within 0.2%.","abstract_has_math":false,"creators":["Saunders, Jessica"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Doctoral","degree_discipline":null,"degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["Erickson, Anna S."],"committee_chairs":[],"committee_members":["Elder, Eric","Hertel, Nolan E.","Rahnema, Farzad","Roper, Justin"],"year":2016,"date_issued":"2016-04-08","date_published":"2016-04-08","updated_at":"2026-11-19T06:09:43Z","subjects":["Prompt gamma","Medical physics"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/55003","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/55003","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F55003","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Erickson, Anna S."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Elder, Eric","Hertel, Nolan E.","Rahnema, Farzad","Roper, Justin"]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["George W. Woodruff School of Mechanical Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Saunders, Jessica"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2016-05-27T13:23:45Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2016-05-27T13:23:45Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2016-05"]},{"key":"dc:date.issued","label":"Date","values":["2016-04-08"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["May 2016"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2016-05-27T13:23:45Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["df2e2349-4cf3-4d53-89e5-adc9b56c9ac6"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Doctor of Philosophy with a Major in Nuclear Engineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["c01ff908-c25f-439b-bf10-a074ed886bb7","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["b2bc2e12-2afc-4a4d-bf4c-0ce7832bcefe"]},{"key":"dc:type","label":"Dc Type","values":["Text","Dissertation"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctoral"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Prompt gamma","Medical physics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/55003"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The goal of this research is to evaluate the secondary prompt gamma (PG) yield from proton therapy at high characteristic energies from MC model simulations and experimental data. Recent studies indicate that target composition influences PG characteristic energy and yield, and the quantification of PG may be used to offer real-time dose verification for proton therapy. In this study PG analysis was performed for MC simulations to evaluate the characteristic measurements and total yield of secondary PG emitted from a target in the 0-8 MeV range from a proton therapy beam over a range of four different beam energies (70 MeV, 160 MeV, 200 MeV, 220 MeV). This was repeated in several target materials (carbon, calcium oxide, calcium fluoride, PMMA, and HDPE) in order to evaluate the influence of the incident energy and the target material on the PG yield and energy spectra. PG energy spectra determined from the specified target materials indicated that the 3.74 MeV energy peak shows a linear correlation between PG intensity and calcium mass fraction of the target material. 6.13 MeV and 4.44 MeV energy peak are not unique to the respective, oxygen and combined oxygen and carbon, mass fraction of the target material. This relationship is complicated by the addition of calcium within the target. Experimental data was collected in order to validate the computational model based on comparison of relative characteristic energy peek intensities. The relative peak ratio determined from experimental data is in good agreement with model prediction, the combined peak ratio is within 0.2%."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph.D."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Secondary prompt gamma-rays to improve proton range verification"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Erickson, Anna S."],"dc:contributor.committeemember":["Elder, Eric","Hertel, Nolan E.","Rahnema, Farzad","Roper, Justin"],"dc:contributor.department":["Mechanical Engineering"],"dc:contributor.other":["George W. Woodruff School of Mechanical Engineering","College of Engineering"],"dc:creator":["Saunders, Jessica"],"dc:date.accessioned":["2016-05-27T13:23:45Z"],"dc:date.available":["2016-05-27T13:23:45Z"],"dc:date.created":["2016-05"],"dc:date.issued":["2016-04-08"],"dc:date.submitted":["May 2016"],"dc:date.updated":["2016-05-27T13:23:45Z"],"dc:description.abstract":["The goal of this research is to evaluate the secondary prompt gamma (PG) yield from proton therapy at high characteristic energies from MC model simulations and experimental data. Recent studies indicate that target composition influences PG characteristic energy and yield, and the quantification of PG may be used to offer real-time dose verification for proton therapy. In this study PG analysis was performed for MC simulations to evaluate the characteristic measurements and total yield of secondary PG emitted from a target in the 0-8 MeV range from a proton therapy beam over a range of four different beam energies (70 MeV, 160 MeV, 200 MeV, 220 MeV). This was repeated in several target materials (carbon, calcium oxide, calcium fluoride, PMMA, and HDPE) in order to evaluate the influence of the incident energy and the target material on the PG yield and energy spectra. PG energy spectra determined from the specified target materials indicated that the 3.74 MeV energy peak shows a linear correlation between PG intensity and calcium mass fraction of the target material. 6.13 MeV and 4.44 MeV energy peak are not unique to the respective, oxygen and combined oxygen and carbon, mass fraction of the target material. This relationship is complicated by the addition of calcium within the target. Experimental data was collected in order to validate the computational model based on comparison of relative characteristic energy peek intensities. The relative peak ratio determined from experimental data is in good agreement with model prediction, the combined peak ratio is within 0.2%."],"dc:description.degree":["Ph.D."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1853/55003"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["df2e2349-4cf3-4d53-89e5-adc9b56c9ac6"],"dc:relation.ispartofseries":["Doctor of Philosophy with a Major in Nuclear Engineering"],"dc:relation.orgunit":["c01ff908-c25f-439b-bf10-a074ed886bb7","7c022d60-21d5-497c-b552-95e489a06569"],"dc:relation.seriesentity":["b2bc2e12-2afc-4a4d-bf4c-0ce7832bcefe"],"dc:subject":["Prompt gamma","Medical physics"],"dc:title":["Secondary prompt gamma-rays to improve proton range verification"],"dc:type":["Text","Dissertation"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Doctoral"]},"updated_at":"2026-11-19T06:09:43Z"}