{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/55014"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/55014","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Facility effects on Helicon ion thruster operation","abstract":"In order to enable comparison of Helicon ion thruster performance across different vacuum test facilities, an understanding of the effect of operating pressure on plasma plume properties is required. Plasma property measurements are compared for thruster operation at two separate vacuum facility operating pressures to determine the effect of neutral ingestion on Helicon ion thruster operation. The ion energy distribution function (IEDF), electron temperature, ion number density, and plasma potential are measured along the thruster main axis for a replica of the Madison Helicon eXperiment. Plasma property values recorded at the ‘high-pressure condition’ (3.0×10^(-4) Torr corrected for argon) are compared to values recorded at the ‘low-pressure condition’ (1.2×10^(-5) Torr corrected for argon) for thruster operation at 100 - 500 watts radio frequency forward power, 340 – 700 gauss source region magnetic field strength, and 1.3 - 60 sccm argon volumetric flow rate (0.039-1.782 mg/s). Differences in plasma behavior at the ‘high-pressure condition’ result from two primary neutral-plume interactions: collisions between accelerated beam ions and ingested neutrals leading to a reduction of ion energy and neutral ionization downstream of the thruster exit due to electron-neutral collisions. Electron temperature at higher operating pressures is lowered due to an electron cooling effect resulting from repeated collisions with neutral atoms. Results suggest that Helicon ion thruster plasma properties are greatly influenced when subjected to neutral ingestion.","abstract_html":"In order to enable comparison of Helicon ion thruster performance across different vacuum test facilities, an understanding of the effect of operating pressure on plasma plume properties is required. Plasma property measurements are compared for thruster operation at two separate vacuum facility operating pressures to determine the effect of neutral ingestion on Helicon ion thruster operation. The ion energy distribution function (IEDF), electron temperature, ion number density, and plasma potential are measured along the thruster main axis for a replica of the Madison Helicon eXperiment. Plasma property values recorded at the ‘high-pressure condition’ (3.0×10^(-4) Torr corrected for argon) are compared to values recorded at the ‘low-pressure condition’ (1.2×10^(-5) Torr corrected for argon) for thruster operation at 100 - 500 watts radio frequency forward power, 340 – 700 gauss source region magnetic field strength, and 1.3 - 60 sccm argon volumetric flow rate (0.039-1.782 mg/s). Differences in plasma behavior at the ‘high-pressure condition’ result from two primary neutral-plume interactions: collisions between accelerated beam ions and ingested neutrals leading to a reduction of ion energy and neutral ionization downstream of the thruster exit due to electron-neutral collisions. Electron temperature at higher operating pressures is lowered due to an electron cooling effect resulting from repeated collisions with neutral atoms. Results suggest that Helicon ion thruster plasma properties are greatly influenced when subjected to neutral ingestion.","abstract_has_math":false,"creators":["Caruso, Natalie R. S."],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Doctoral","degree_discipline":null,"degree_department":"Aerospace Engineering","school":null,"contributors":[],"advisors":["Walker, Mitchell L. R."],"committee_chairs":[],"committee_members":["Seitzman, Jerry","Menon, Suresh","Sun, Wenting","Simon, Sven"],"year":2016,"date_issued":"2016-04-08","date_published":"2016-04-08","updated_at":"2026-11-19T05:15:02Z","subjects":["Helicon ion thruster","MadHeX","Facility effects","Neutral ingestion","Magnetic nozzle","Plasma","Electric propulsion"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/55014","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/55014","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F55014","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Walker, Mitchell L. R."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Seitzman, Jerry","Menon, Suresh","Sun, Wenting","Simon, Sven"]},{"key":"dc:contributor.department","label":"Department","values":["Aerospace Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["College of Engineering","Daniel Guggenheim School of Aerospace Engineering"]},{"key":"dc:creator","label":"Author","values":["Caruso, Natalie R. S."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2016-05-27T13:23:57Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2016-05-27T13:23:57Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2016-05"]},{"key":"dc:date.issued","label":"Date","values":["2016-04-08"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["May 2016"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2016-05-27T13:23:57Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["060e1082-d47d-49ca-b7e3-198c294faa2b"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Doctor of Philosophy with a Major in Aerospace Engineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["7c022d60-21d5-497c-b552-95e489a06569","a348b767-ea7e-4789-af1f-1f1d5925fb65"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["f6a932db-1cde-43b5-bcab-bf573da55ed6"]},{"key":"dc:type","label":"Dc Type","values":["Text","Dissertation"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctoral"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Helicon ion thruster","MadHeX","Facility effects","Neutral ingestion","Magnetic nozzle","Plasma","Electric propulsion"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/55014"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["In order to enable comparison of Helicon ion thruster performance across different vacuum test facilities, an understanding of the effect of operating pressure on plasma plume properties is required. Plasma property measurements are compared for thruster operation at two separate vacuum facility operating pressures to determine the effect of neutral ingestion on Helicon ion thruster operation. The ion energy distribution function (IEDF), electron temperature, ion number density, and plasma potential are measured along the thruster main axis for a replica of the Madison Helicon eXperiment. Plasma property values recorded at the ‘high-pressure condition’ (3.0×10^(-4) Torr corrected for argon) are compared to values recorded at the ‘low-pressure condition’ (1.2×10^(-5) Torr corrected for argon) for thruster operation at 100 - 500 watts radio frequency forward power, 340 – 700 gauss source region magnetic field strength, and 1.3 - 60 sccm argon volumetric flow rate (0.039-1.782 mg/s). Differences in plasma behavior at the ‘high-pressure condition’ result from two primary neutral-plume interactions: collisions between accelerated beam ions and ingested neutrals leading to a reduction of ion energy and neutral ionization downstream of the thruster exit due to electron-neutral collisions. Electron temperature at higher operating pressures is lowered due to an electron cooling effect resulting from repeated collisions with neutral atoms. Results suggest that Helicon ion thruster plasma properties are greatly influenced when subjected to neutral ingestion."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph.D."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Facility effects on Helicon ion thruster operation"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Walker, Mitchell L. R."],"dc:contributor.committeemember":["Seitzman, Jerry","Menon, Suresh","Sun, Wenting","Simon, Sven"],"dc:contributor.department":["Aerospace Engineering"],"dc:contributor.other":["College of Engineering","Daniel Guggenheim School of Aerospace Engineering"],"dc:creator":["Caruso, Natalie R. S."],"dc:date.accessioned":["2016-05-27T13:23:57Z"],"dc:date.available":["2016-05-27T13:23:57Z"],"dc:date.created":["2016-05"],"dc:date.issued":["2016-04-08"],"dc:date.submitted":["May 2016"],"dc:date.updated":["2016-05-27T13:23:57Z"],"dc:description.abstract":["In order to enable comparison of Helicon ion thruster performance across different vacuum test facilities, an understanding of the effect of operating pressure on plasma plume properties is required. Plasma property measurements are compared for thruster operation at two separate vacuum facility operating pressures to determine the effect of neutral ingestion on Helicon ion thruster operation. The ion energy distribution function (IEDF), electron temperature, ion number density, and plasma potential are measured along the thruster main axis for a replica of the Madison Helicon eXperiment. Plasma property values recorded at the ‘high-pressure condition’ (3.0×10^(-4) Torr corrected for argon) are compared to values recorded at the ‘low-pressure condition’ (1.2×10^(-5) Torr corrected for argon) for thruster operation at 100 - 500 watts radio frequency forward power, 340 – 700 gauss source region magnetic field strength, and 1.3 - 60 sccm argon volumetric flow rate (0.039-1.782 mg/s). Differences in plasma behavior at the ‘high-pressure condition’ result from two primary neutral-plume interactions: collisions between accelerated beam ions and ingested neutrals leading to a reduction of ion energy and neutral ionization downstream of the thruster exit due to electron-neutral collisions. Electron temperature at higher operating pressures is lowered due to an electron cooling effect resulting from repeated collisions with neutral atoms. Results suggest that Helicon ion thruster plasma properties are greatly influenced when subjected to neutral ingestion."],"dc:description.degree":["Ph.D."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1853/55014"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["060e1082-d47d-49ca-b7e3-198c294faa2b"],"dc:relation.ispartofseries":["Doctor of Philosophy with a Major in Aerospace Engineering"],"dc:relation.orgunit":["7c022d60-21d5-497c-b552-95e489a06569","a348b767-ea7e-4789-af1f-1f1d5925fb65"],"dc:relation.seriesentity":["f6a932db-1cde-43b5-bcab-bf573da55ed6"],"dc:subject":["Helicon ion thruster","MadHeX","Facility effects","Neutral ingestion","Magnetic nozzle","Plasma","Electric propulsion"],"dc:title":["Facility effects on Helicon ion thruster operation"],"dc:type":["Text","Dissertation"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Doctoral"]},"updated_at":"2026-11-19T05:15:02Z"}