{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/55061"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/55061","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Transient & steady-state thermodynamic modeling of modular data centers","abstract":"The data center industry currently focuses on initiatives to reduce its enormous energy consumption and minimize its adverse environmental impact. Modular data centers provide considerable operational flexibility in that they are mobile, and are manufactured using standard containers. This thesis aims at developing steady-state energy and exergy destruction models for modular data centers using four different cooling approaches: direct expansion cooling, direct and indirect evaporative cooling, and free air cooling. Furthermore, transient thermal response of these data centers to dynamic loads, such as varying server load through change in user requirement over the cloud, and/or to changes in outside weather conditions has been studied. The effect of server thermal mass has also been accounted for in developing the transient regime. The change in performance of the data center is reported through changes in the Power Usage Effectiveness (PUE) metric, and through change in the exergy destruction in the individual hot and cold aisles. The core simulation software used for this work is EnergyPlus, an open source software from the U.S. Department of Energy. Moreover, EnergyPlus is used as the simulation engine within the in-house developed software package Data Center EnergyPlus (DCE+).","abstract_html":"The data center industry currently focuses on initiatives to reduce its enormous energy consumption and minimize its adverse environmental impact. Modular data centers provide considerable operational flexibility in that they are mobile, and are manufactured using standard containers. This thesis aims at developing steady-state energy and exergy destruction models for modular data centers using four different cooling approaches: direct expansion cooling, direct and indirect evaporative cooling, and free air cooling. Furthermore, transient thermal response of these data centers to dynamic loads, such as varying server load through change in user requirement over the cloud, and/or to changes in outside weather conditions has been studied. The effect of server thermal mass has also been accounted for in developing the transient regime. The change in performance of the data center is reported through changes in the Power Usage Effectiveness (PUE) metric, and through change in the exergy destruction in the individual hot and cold aisles. The core simulation software used for this work is EnergyPlus, an open source software from the U.S. Department of Energy. Moreover, EnergyPlus is used as the simulation engine within the in-house developed software package Data Center EnergyPlus (DCE+).","abstract_has_math":false,"creators":["Khalid, Rehan"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Masters","degree_discipline":null,"degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["Joshi, Yogendra"],"committee_chairs":[],"committee_members":["Kumar, Satish","Wemhoff, Aaron P."],"year":2016,"date_issued":"2016-05-10","date_published":"2016-05-10","updated_at":"2026-11-19T04:07:03Z","subjects":["Modular","Data center","Modeling","EnergyPlus","Transient","Steady state"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/55061","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/55061","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F55061","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Joshi, Yogendra"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Kumar, Satish","Wemhoff, Aaron P."]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["George W. Woodruff School of Mechanical Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Khalid, Rehan"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2016-05-27T13:25:13Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2016-05-27T13:25:13Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2016-05"]},{"key":"dc:date.issued","label":"Date","values":["2016-05-10"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["May 2016"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2016-05-27T13:25:13Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["63ef328b-076b-44b7-92a9-0f7dd03fa1fa"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["c01ff908-c25f-439b-bf10-a074ed886bb7","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:type","label":"Dc Type","values":["Text","Thesis"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Modular","Data center","Modeling","EnergyPlus","Transient","Steady state"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/55061"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The data center industry currently focuses on initiatives to reduce its enormous energy consumption and minimize its adverse environmental impact. Modular data centers provide considerable operational flexibility in that they are mobile, and are manufactured using standard containers. This thesis aims at developing steady-state energy and exergy destruction models for modular data centers using four different cooling approaches: direct expansion cooling, direct and indirect evaporative cooling, and free air cooling. Furthermore, transient thermal response of these data centers to dynamic loads, such as varying server load through change in user requirement over the cloud, and/or to changes in outside weather conditions has been studied. The effect of server thermal mass has also been accounted for in developing the transient regime. The change in performance of the data center is reported through changes in the Power Usage Effectiveness (PUE) metric, and through change in the exergy destruction in the individual hot and cold aisles. The core simulation software used for this work is EnergyPlus, an open source software from the U.S. Department of Energy. Moreover, EnergyPlus is used as the simulation engine within the in-house developed software package Data Center EnergyPlus (DCE+)."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.S."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Transient & steady-state thermodynamic modeling of modular data centers"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Joshi, Yogendra"],"dc:contributor.committeemember":["Kumar, Satish","Wemhoff, Aaron P."],"dc:contributor.department":["Mechanical Engineering"],"dc:contributor.other":["George W. Woodruff School of Mechanical Engineering","College of Engineering"],"dc:creator":["Khalid, Rehan"],"dc:date.accessioned":["2016-05-27T13:25:13Z"],"dc:date.available":["2016-05-27T13:25:13Z"],"dc:date.created":["2016-05"],"dc:date.issued":["2016-05-10"],"dc:date.submitted":["May 2016"],"dc:date.updated":["2016-05-27T13:25:13Z"],"dc:description.abstract":["The data center industry currently focuses on initiatives to reduce its enormous energy consumption and minimize its adverse environmental impact. Modular data centers provide considerable operational flexibility in that they are mobile, and are manufactured using standard containers. This thesis aims at developing steady-state energy and exergy destruction models for modular data centers using four different cooling approaches: direct expansion cooling, direct and indirect evaporative cooling, and free air cooling. Furthermore, transient thermal response of these data centers to dynamic loads, such as varying server load through change in user requirement over the cloud, and/or to changes in outside weather conditions has been studied. The effect of server thermal mass has also been accounted for in developing the transient regime. The change in performance of the data center is reported through changes in the Power Usage Effectiveness (PUE) metric, and through change in the exergy destruction in the individual hot and cold aisles. The core simulation software used for this work is EnergyPlus, an open source software from the U.S. Department of Energy. Moreover, EnergyPlus is used as the simulation engine within the in-house developed software package Data Center EnergyPlus (DCE+)."],"dc:description.degree":["M.S."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1853/55061"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["63ef328b-076b-44b7-92a9-0f7dd03fa1fa"],"dc:relation.orgunit":["c01ff908-c25f-439b-bf10-a074ed886bb7","7c022d60-21d5-497c-b552-95e489a06569"],"dc:subject":["Modular","Data center","Modeling","EnergyPlus","Transient","Steady state"],"dc:title":["Transient & steady-state thermodynamic modeling of modular data centers"],"dc:type":["Text","Thesis"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Masters"]},"updated_at":"2026-11-19T04:07:03Z"}